The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Low-Power Wearable ECG Monitoring System for Multiple-Patient Remote Monitoring
Open accessAbstract
Many devices and solutions for remote electrocardiogram (ECG) monitoring have been proposed in the literature. These solutions typically have a large marginal cost per added sensor and are not seamlessly integrated with other smart home solutions. Here, we propose an ECG remote monitoring system that is dedicated to non-technical users in need of long-term health monitoring in residential environments and is integrated in a broader Internet-of-Things (IoT) infrastructure. Our prototype consists of a complete vertical solution with a series of advantages with respect to the state of the art, considering both the prototypes with integrated front end and prototypes realized with off-the-shelf components: 1) ECG prototype sensors with record-low energy per effective number of quantized levels; 2) an architecture providing low marginal cost per added sensor/user; and 3) the possibility of seamless integration with other smart home systems through a single IoT infrastructure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Information theory, inference, and learning algorithms
(2004) · Choice Reviews Online · doi:10.5860/choice.41-5949 · Cited by 6,362
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Driven-right-leg circuit design
Winter, B. B., & Webster, J. G. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325168 · Cited by 443
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Bayesian probabilistic population projections for all countries
Raftery, A. E., Li, N., Ševčíková, H., Gerland, P., & Heilig, G. K. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211452109 · Cited by 298
A Zigbee-Based Wearable Physiological Parameters Monitoring System
Malhi, K., Mukhopadhyay, S. C., Schnepper, J., Haefke, M., & Ewald, H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2091719 · Cited by 282
A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
Kim, H., Kim, S., Van Helleputte, N., Artes, A., Konijnenburg, M., Huisken, J., Van Hoof, C., & Yazicioglu, R. F. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2260159 · Cited by 230
Taji, B., Shirmohammadi, S., Groza, V., & Batkin, I. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2289072 · Cited by 180
Last-Meter Smart Grid Embedded in an Internet-of-Things Platform
Spano, E., Niccolini, L., Pascoli, S. D., & Iannaccone, G. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2342796 · Cited by 176
Self-citationAn Energy-Efficient ASIC for Wireless Body Sensor Networks in Medical Applications
Zhang, X., Jiang, H., Zhang, L., Zhang, C., Wang, Z., & Chen, X. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2031627 · Cited by 172
Sensing Devices and Sensor Signal Processing for Remote Monitoring of Vital Signs in CHF Patients
Fanucci, L., Saponara, S., Bacchillone, T., Donati, M., Barba, P., Sanchez-Tato, I., & Carmona, C. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2218681 · Cited by 153
Information Theory, Inference, and Learning Algorithms
Yang, Y. (2005) · Journal of the American Statistical Association · doi:10.1198/jasa.2005.s54 · Cited by 147
Ground-Free ECG Recording with Two Electrodes
Thakor, N. V., & Webster, J. G. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326595 · Cited by 143
Recommendations for measurement standards in quantitative electrocardiography
(1985) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a061766 · Cited by 132
Low-Power Wireless ECG Acquisition and Classification System for Body Sensor Networks
Lee, S.-Y., Hong, J.-H., Hsieh, C., Liang, M., Chien, S.-Y. C., & Lin, K.-H. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2310354 · Cited by 114
Wireless Sensor Networks for Monitoring Physiological Signals of Multiple Patients
Dilmaghani, R., Bobarshad, H., Ghavami, M., Choobkar, S., & Wolfe, C. D. A. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2114661 · Cited by 112
Total Removal of Baseline Drift from ECG Signal
Chouhan, V. S., & Mehta, S. S. (2007) · International Conference on Computing: Theory and Applications · doi:10.1109/iccta.2007.126 · Cited by 104
Chuo, Y., Marzencki, M., Hung, B., Jaggernauth, C., Tavakolian, K., Lin, P., & Kaminska, B. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2052616 · Cited by 102
An ECG-on-Chip With 535 nW/Channel Integrated Lossless Data Compressor for Wireless Sensors
Deepu, C. J., Zhang, X., Liew, W.-S., Wong, D. L. T., & Lian, Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2349994 · Cited by 92
Gomez-Clapers, J., & Casanella, R. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2118201 · Cited by 77
A transconductance driven-right-leg circuit
Spinelli, E. M., Martínez, N., & Mayosky, M. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.804574 · Cited by 75
A Wearable Cardiac Monitor for Long-Term Data Acquisition and Analysis
Winokur, E. S., Delano, M. K., & Sodini, C. G. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217958 · Cited by 64
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
Deepu, C. J., Xu, X., Zou, X., Yao, L., & Lian, Y. (2010) · IEEE International Workshop on Electronic Design, Test and Applications (DELTA) · doi:10.1109/delta.2010.43 · Cited by 41
A long-term wearable electrocardiogram measurement system
Delano, M. K., & Sodini, C. G. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575459 · Cited by 38
Altini, M., Polito, S., Penders, J., Kim, H., Van Helleputte, N., Kim, S., & Yazicioglu, F. (2011) · Proceedings of the 2nd Conference on Wireless Health · doi:10.1145/2077546.2077564 · Cited by 36
A robust wearable u-healthcare platform in wireless sensor network
Lee, S., & Chung, W. (2014) · Journal of Communications and Networks · doi:10.1109/jcn.2014.000077 · Cited by 35
A Wearable Mobile Electrocardiogram measurement device with novel dry polymer-based electrodes
Wang, I.-J., Liao, L., Wang, Y.-T., Chen, C., Lin, B., Lu, S.-W., & Lin, C. (2010) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2010.5686658 · Cited by 35
Telehealth using ECG sensor and accelerometer
Gjoreski, H., Rashkovska, A., Kozina, S., Luštrek, M., & Gams, M. (2014) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.1109/mipro.2014.6859575 · Cited by 33
Design of a gel-less two-electrode ECG monitor
Richard, E., & Chan, A. D. C. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480198 · Cited by 31
Wearable ECG System for Health and Sports Monitoring
Valchinov, E. S., Antoniou, A., Rotas, K., et al. (2014) · doi:10.4108/icst.mobihealth.2014.257236 · Cited by 27
A new approach to design ambient sensor network for real time healthcare monitoring system
Jung, S., Kwon, T.-H., & Chung, W. (2009) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2009.5398310 · Cited by 22
Multi-functional wireless body sensor - Analysis of autonomy
Bregar, K., & Avbelj, V. (2013) · International Convention on Information and Communication Technology, Electronics and Microelectronics · Cited by 8
A Study on Power Consumption and Transmission Rate in ECG Signal Processing in Mobile Environment
Kim, N. J., Hong, J. H., & Lee, T.-S. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_1041 · Cited by 6
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Enabling Technologies for the Internet of Health Things
Rodrigues, J. J. P. C., De Rezende Segundo, D. B., Junqueira, H. A., Sabino, M. H., Prince, R. M., Al-Muhtadi, J., & De Albuquerque, V. H. C. (2018) · IEEE Access · doi:10.1109/access.2017.2789329 · Cited by 413
ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., T. El Kassabi, H., Ismail, H., & Nujum Navaz, A. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 357
Baig, M. M., GholamHosseini, H., Moqeem, A. A., Mirza, F., & Lindén, M. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0760-1 · Cited by 351
Sundaravadivel, P., Kougianos, E., Mohanty, S. P., & Ganapathiraju, M. K. (2018) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2017.2755378 · Cited by 305
Metadata
- Authors
- Spano, E., Di Pascoli, S., & Iannaccone, G.
- Venue
- IEEE Sensors Journal
- Published
- 2016-07
- Volume
- 16
- Issue
- 13
- Pages
- 5452-5462
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2346753755
- Cited by
- 256
- References
- 37
- FWCI
- 20.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.