Motion Intention Prediction and Joint Trajectories Generation Toward Lower Limb Prostheses Using EMG and IMU Signals
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Powered intelligent lower limb prostheses have been gaining interest as they provide functionality for walking on different terrains. This study proposes a hierarchical planner for intelligent lower limb prostheses based on sensor fusion and a central pattern generator (CPG). Electromyographic (EMG) and inertial measurement unit (IMU) signals were recorded and fused in the feature and decision levels. The high-level planner consists of cascade classifiers with a gait phase dependence. A secondary classifier for each stand phase and swing phase was developed to recognize five gait patterns. The mid-level planner was designed as a walking frequency estimator based on the Newton method. The low-level planner incorporates the CPG models, achieving the planning of lower limb joint trajectories. The proposed layered planner can recognize the users’ walking intention and gait speed in real-time, ensuring coordination between the joints of both legs. Eight healthy subjects were recruited, and the average accuracy of motion pattern recognition reached 99.13% and 99.39% for the standing and swing phases, respectively. The relative root mean square error (RMSE) of the walking frequency estimate was 2.3% under approximately 3.5 m/s gait speed. The promising results indicate that this method effectively predicts the continuous joint angle for lower limb prostheses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Motion trajectories of corresponding limbs are quantified through a sensor fusion-based hierarchical planner 131 , improving the recognition accuracy of motion intent in common fine movements such as grasping or knee flexion.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [131]
In the citing paper
“This type of research is often used in hand rehabilitation training 98 , gesture recognition systems 132 , and prosthetic control 131,133 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [131]
In the citing paper
“| IMU and EMG | Intelligent prosthesis | 5 | 91.8% | 131 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [131]
Citations
Cites
SMOTE synthetic minority over-sampling technique
Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002) · Journal of Artificial Intelligence Research · doi:10.1613/jair.953 · Cited by 32,865
Central pattern generators for locomotion control in animals and robots: A review
Ijspeert, A. J. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.014 · Cited by 1,853
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Cohen, A. H., Holmes, P. J., & Rand, R. H. (1982) · Journal of Mathematical Biology · doi:10.1007/bf00276069 · Cited by 542
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Multiclass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis
Varol, H. A., Sup, F., & Goldfarb, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034734 · Cited by 425
Online Optimization of Swimming and Crawling in an Amphibious Snake Robot
Crespi, A., & Ijspeert, A. J. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915426 · Cited by 332
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Quintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Vallery, H., van Asseldonk, E. H. F., Buss, M., & van der Kooij, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008278 · Cited by 228
Fleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
Chen, J., Zhang, X., Cheng, Y., & Xi, N. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.10.002 · Cited by 177
A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation
Maqbool, H. F., Husman, M. A. B., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2636367 · Cited by 138
Experimental Studies of a Neural Oscillator for Biped Locomotion with QRIO
Endo, G., Nakanishi, J., Morimoto, J., & Cheng, G. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570183 · Cited by 125
Fusion of Multi-Sensor-Based Biomechanical Gait Analysis Using Vision and Wearable Sensor
Bijalwan, V., Semwal, V. B., & Mandal, T. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3066473 · Cited by 122
Gui, K., Liu, H., & Zhang, D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2703586 · Cited by 120
Self-citationMendez, J., Hood, S., Gunnel, A., & Lenzi, T. (2020) · Science Robotics · doi:10.1126/scirobotics.aba6635 · Cited by 105
Speed-Adaptation Mechanism: Robotic Prostheses Can Actively Regulate Joint Torque
Lenzi, T., Hargrove, L., & Sensinger, J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360305 · Cited by 92
A Noncontact Capacitive Sensing System for Recognizing Locomotion Modes of Transtibial Amputees
Zheng, E., Wang, L., Wei, K., & Wang, Q. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2334316 · Cited by 87
Zheng, E., & Wang, Q. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2529581 · Cited by 84
Liu, X., & Wang, Q. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2990668 · Cited by 83
Examination of the Performance Characteristics of Velostat as an In-Socket Pressure Sensor
Hopkins, M., Vaidyanathan, R., & McGregor, A. H. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2978431 · Cited by 78
Interjoint coordination in lower limbs during different movements in humans
St-Onge, N., & Feldman, A. G. (2003) · Experimental Brain Research · doi:10.1007/s00221-002-1212-8 · Cited by 77
Qiu, S., Guo, W. P., Caldwell, D. G., & Chen, F. (2020) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.2968845 · Cited by 77
Adaptive Oscillator-Based Robust Control for Flexible Hip Assistive Exoskeleton
Xue, T., Wang, Z., Zhang, T., & Zhang, M. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2926678 · Cited by 72
Complementary limb motion estimation for the control of active knee prostheses
Vallery, H., Burgkart, R., Hartmann, C., Mitternacht, J., Riener, R., & Buss, M. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.057 · Cited by 66
sEMG-based consecutive estimation of human lower limb movement by using multi-branch neural network
Wang, X., Dong, D., Chi, X., Wang, S., Miao, Y., An, M., & Gavrilov, A. I. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102781 · Cited by 63
Hussain, T., Iqbal, N., Maqbool, H. F., Khan, M., Awad, M. I., & Dehghani-Sanij, A. A. (2020) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2020.05.010 · Cited by 58
Hansen, A. H., & Childress, D. S. (2010) · Disability and Rehabilitation · doi:10.3109/09638288.2010.502586 · Cited by 54
Modeling bipedal locomotion trajectories using hybrid automata
Nandi, G. C., Semwal, V. B., Raj, M., & Jindal, A. (2016) · 2016 IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2016.7848159 · Cited by 43
Raj, M., Semwal, V. B., & Nandi, G. C. (2016) · Neural Computing and Applications · doi:10.1007/s00521-016-2744-3 · Cited by 40
Zhang, B., Wang, S., Zhou, M., & Xu, W. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2021.103842 · Cited by 38
Real-Time Detection of Actual and Early Gait Events During Level-Ground and Ramp Walking
Sahoo, S., Saboo, M., Pratihar, D. K., & Mukhopadhyay, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2980863 · Cited by 32
Cybernetic knee prosthesis: application of an adaptive central pattern generator
Torrealba, R. R., Cappelletto, J., Fermín, L., Fernández, G., & Grieco, J. C. (2012) · Kybernetes · doi:10.1108/03684921211213034 · Cited by 27
Robotic hip-disarticulation prosthesis: evaluation of prosthetic gaits in a non-amputee individual
Ueyama, Y., Kubo, T., & Shibata, M. (2019) · Advanced Robotics · doi:10.1080/01691864.2019.1705908 · Cited by 25
Hu, B. H., Rouse, E. J., & Hargrove, L. J. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00127 · Cited by 22
A Gait Phase Detection Method in Complex Environment Based on DTW-Mean Templates
Huang, L., Zheng, J., & Hu, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3072102 · Cited by 19
Qiu, S., Guo, W. P., Zha, F., Deng, J., & Wang, X. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.672582 · Cited by 13
Naeem, A., Rizwan, M., Maqbool, H. F., Ahsan, M., Raza, A., Abouhossein, A., & Dehghani-Sanij, A. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103366 · Cited by 9
Tahir, M., Hussain, T., Iqbal, N., Maqbool, H. F., & Khan, M. (2020) · International Journal of Sensor Networks · doi:10.1504/ijsnet.2020.105562 · Cited by 9
Choi, T., Im, C., Kim, S., Kim, H., & Lee, J. M. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512867 · Cited by 5
Cited by
Suo, J., Liu, Y., Wang, J., Chen, M., Wang, K., Yang, X., Yao, K., Roy, V. A. L., Yu, X., Daoud, W. A., et al. (2024) · Advanced Science · doi:10.1002/advs.202305025 · Cited by 72
A Systematic Review of Gait Analysis in the Context of Multimodal Sensing Fusion and AI
Katmah, R., Shehhi, A. A., Jelinek, H. F., Hulleck, A. A., & Khalaf, K. A. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3325215 · Cited by 71
“Wang et al. [73] also made accurate predictions for the continuous joint angle using a hierarchical planner, however, according to research conducted by [74], bidirectional long short term memory (BiLSTM) generates the most accurate predictions of lower limb joint angles throughout the entire…”
MethodUse of Artificial Intelligence Techniques to Assist Individuals with Physical Disabilities
Pancholi, S., Wachs, J. P., & Duerstock, B. S. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-082222-012531 · Cited by 77
Interactive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“2) Multisource Information Fusion: Many researchers have improved the accuracy of intention recognition by fusing diverse types of motion-related information [83], [84], [119], [120], [121], [122], [123], [124] and considering the correlation and complementarity between different information modes.”
BackgroundHwang, S., Kwon, N., Lee, D., Kim, J., Yang, S., Youn, I., Moon, H.-J., Sung, J.-K., & Han, S. (2025) · Sensors · doi:10.3390/s25113309 · Cited by 63
Metadata
- Authors
- Wang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D.
- Affiliations
- Shanghai Jiao Tong University (CN)
- University of Bath (GB)
- Venue
- IEEE Sensors Journal
- Published
- 2022-06-01
- Volume
- 22
- Issue
- 11
- Pages
- 10719-10729
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4226101141
- Cited by
- 70
- References
- 42
- Citations by year
- 2026: 17 · 2025: 26 · 2024: 17 · 2023: 9 · 2022: 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- National Key Research and Development Program of China (2018YFB1307301)
- National Natural Science Foundation of China (91848112, 62176158)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Locomotion and Control
- Keywords
- lower limb prosthesis, joint trajectory generation, central pattern generator, gait phase detection, hierarchical motion planning, gait speed estimation, powered prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.