A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper reports a driver circuitry to generate bi-phasic (anodic and cathodic) current pulses for stimulating the retinal layer through electrodes which is part of a retinal prosthetic device for implants in blind patients affected by retinitis pigmentosa (RP) and age-related macular degeneration (AMD). Dual voltage architecture is used to halve the number of interface leads from the chip to the stimulation sites compared to a single voltage supply. The driver circuitry is designed to deliver currents with six bit resolution for a wide range of full scale currents up to 600 /spl mu/A. To cater to the varying stimulus requirements among patients and different regions of the retina, variable gain architecture is used to achieve fine resolution even for a narrow range of stimulus. 1:8 demultiplexing feature is embedded within the output stage thus allowing one DAC for eight outputs. A novel charge cancellation circuitry with current limiting capability is implemented to discharge the electrodes for medical safety. Measurement results of a prototype chip fabricated in 1.5-/spl mu/m CMOS technology are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 3×
“Based on experimental results in a 4 4 implant in a 74 year old male with X-linked Retinitis Pigmentosa [20], this can happen in two different cases: 1) Different regions of retina may have varying levels of retinal degradation.”
BackgroundSelf-citationA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198 · cited 1×
“600–1000 electrodes will be needed to restore visual function to a level that would allow blind to read, navigate a room unaided, and recognize faces [14]–[17].”
BackgroundReading speed with a pixelized vision system
Cha, K., Boman, D. K., Horch, K. W., & Normann, R. A. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000673 · Cited by 167
Cited by
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
A 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
“• Charge-balancing techniques relying on electrode shortening [17] or discharge resistors at the stimulation electrodes [14].”
BackgroundMethodNoorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Inductor Modeling in Wireless Links for Implantable Electronics
Yang, Z., Liu, W., & Basham, E. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.904189 · Cited by 199
Self-citationAn active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170
Metadata
- Authors
- Sivaprakasam, M., Liu, W., Humayun, M. S., & Weiland, J. D.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2005-03
- Volume
- 40
- Issue
- 3
- Pages
- 763-771
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2122970027
- Cited by
- 155
- References
- 5
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.