The DOI matches its Crossref record.
A 350 $\mu$W CMOS MSK Transmitter and 400 $\mu$W OOK Super-Regenerative Receiver for Medical Implant Communications
Open accessAbstract
Recent advances in the medical field are spurring the need for ultra-low power transceivers for wireless communication with medical implants. To deal with the growing demand for medical telemetry, the FCC commissioned the medical implant communications services (MICS) standard in 1999 in the 402-405 MHz band. This paper presents a 350 muW FSK/MSK direct modulation transmitter and a 400 muW OOK super-regenerative receiver (SRR) specifically optimized for medical implant communications. The transceiver is implemented in 90 nm CMOS and digitally tunes 24 MHz in frequency steps smaller than 2 kHz. The transmitter meets MICS mask specifications with data rates up to 120 kb/s consuming only 2.9 nJ/bit; the receiver has a sensitivity better than -99 dBm with a data rate of 40 kb/s or -93 dBm with a data rate of 120 kb/s consuming 3.3 nJ/bit. A frequency correction loop incorporating the base-station is prototyped to eliminate the need for a frequency synthesizer in the implant while still achieving frequency stability of less than 3 ppm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient backscatter: wireless communication out of thin air
Liu, V., Parks, A., Talla, V., Gollakota, S., Wetherall, D., & Smith, J. R. (2013) · Proceedings of the ACM SIGCOMM 2013 conference on SIGCOMM · doi:10.1145/2486001.2486015 · Cited by 1,060
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Self-citationChen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
Self-citationChow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
“Work presented in [23] and [24] show data rates around 100–250 kb/s with around 300–500 W n of power, and [25] achieves 200 kb/s with a power consumption of only 90 W n .”
BackgroundA 0.7-V 17.4-/spl mu/W 3-Lead Wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J., Liew, W.-S., & Lian, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2279398 · Cited by 73
“So FSK modulation is selected due to its constant envelope that allows for high efficient nonlinear PA and simplifies the circuit implementation via directly modulating the oscillator [20].”
BackgroundInfluential
Metadata
- Authors
- Bohorquez, J. L., Chandrakasan, A. P., & Dawson, J. L.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1248-1259
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2126470432
- Cited by
- 246
- References
- 0
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.