An 8-Channel Scalable EEG Acquisition SoC With Patient-Specific Seizure Classification and Recording Processor
Abstract
An 8-channel scalable EEG acquisition SoC is presented to continuously detect and record patient-specific seizure onset activities from scalp EEG. The SoC integrates 8 high-dynamic range Analog Front-End (AFE) channels, a machine-learning seizure classification processor and a 64 KB SRAM. The classification processor exploits the Distributed Quad-LUT filter architecture to minimize the area while also minimizing the overhead in power × delay . The AFE employs a Chopper-Stabilized Capacitive Coupled Instrumentation Amplifier to show NEF of 5.1 and noise RTI of 0.91 μVrmsfor 0.5-100 Hz bandwidth. The classification processor adopts a support-vector machine as a classifier, with a GBW controller that gives real-time gain and bandwidth feedback to AFE to maintain accuracy. The SoC is verified with the Children's Hospital Boston-MIT EEG database as well as with rapid eye blink pattern detection test. The SoC is implemented in 0.18 μm 1P6M CMOS process occupying 25 mm2, and it shows an accuracy of 84.4% in eye blink classification test, at 2.03 μJ/classification energy efficiency. The 64 KB on chip memory can store up to 120 seconds of raw EEG data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Enz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877
Application of machine learning to epileptic seizure onset detection and treatment
Shoeb, A. H. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 885
Self-citationDigital Signal Processing with Field Programmable Gate Arrays
(2007) · Signals and Communication Technology · doi:10.1007/978-3-540-72613-5 · Cited by 529
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Self-citationFan, Q., Sebastiano, F., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143610 · Cited by 473
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
A 6-bit 600-MS/s 5.3-mW Asynchronous ADC in 0.13-$\mu{\hbox{m}}$ CMOS
Chen, S.-W. M., & Brodersen, R. W. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884231 · Cited by 423
Brain stimulation for epilepsy
Theodore, W. H., & Fisher, R. S. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00664-1 · Cited by 410
An Energy-Efficient Charge Recycling Approach for a SAR Converter With Capacitive DAC
Ginsburg, B. P., & Chandrakasan, A. P. (2005) · 2005 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2005.1464555 · Cited by 342
Self-citation
Cited by
Personalized Keystroke Dynamics for Self-Powered Human–Machine Interfacing
Chen, J., Zhu, G., Yang, J., Jing, Q., Bai, P., Yang, W., Qi, X., Su, Y., & Wang, Z. L. (2015) · ACS Nano · doi:10.1021/nn506832w · Cited by 270
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Metadata
- Authors
- Yoo, J., Yan, L., El-Damak, D., Altaf, M. A. B., Shoeb, A. H., & Chandrakasan, A. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2013-01
- Volume
- 48
- Issue
- 1
- Pages
- 214-228
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2042682017
- Cited by
- 274
- References
- 16
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An 8-Channel Scalable EEG Acquisition SoC With Patient-Specific Seizure Classification and Recording Processor. https://app.cochat.ai/papers/10.1109/jssc.2012.2221220
- The paper
- Yoo, J., Yan, L., El-Damak, D., Altaf, M. A. B., Shoeb, A. H., & Chandrakasan, A. P. (2013). An 8-Channel Scalable EEG Acquisition SoC With Patient-Specific Seizure Classification and Recording Processor. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2012.2221220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.