A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS
Open accessThe DOI matches its Crossref record; 17 of the 22 references it cites were found in a registry or an index.
Abstract
Miniature mm3-sized sensor nodes have a very tight power budget, in particular, when a long operational lifetime is required, which is the case, e.g., for implantable devices or unobtrusive IoT nodes. This paper presents a fully integrated signal acquisition IC for these emerging applications. It integrates an amplifier with 32 dB gain and 370 Hz bandwidth that includes positive feedback to enhance input impedance and dc offset compensation. The IC includes also a 10 bit 1 kS/s SAR ADC as well as a clock generator and voltage and current biasing circuits. The overall system achieves an input noise of 27 μVrms, consumes 3 nW from a 0.6 V supply, occupies 0.20 mm2in 65 nm CMOS, and has a single-wire data interface. The amplifier achieves an noise-efficiency factor (NEF) of 2.1 and the ADC has a figure-of-merit (FoM) of 1.5 fJ/conversion-step. Measurements confirm reliable operation for supplies from 0.50 to 0.70 V and temperatures in the range of 0-85 °C. As an application example, an ECG recording is successfully performed with the system while a 0.69 mm2photodiode array provides its power supply in indoor lighting conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
A 10 b, 20 Msample/s, 35 mW pipeline A/D converter
Cho, T. B., & Gray, P. R. (1995) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.364429 · Cited by 633
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
A 6-bit 600-MS/s 5.3-mW Asynchronous ADC in 0.13-$\mu{\hbox{m}}$ CMOS
Chen, S.-W. M., & Brodersen, R. W. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884231 · Cited by 423
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
A 26 $\mu$W 8 bit 10 MS/s Asynchronous SAR ADC for Low Energy Radios
Harpe, P. J. A., Zhou, C., Bi, Y., van der Meijs, N. P., Wang, X., Philips, K., Dolmans, G., & de Groot, H. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143870 · Cited by 354
Self-citation11.2 A 0.85fJ/conversion-step 10b 200kS/s subranging SAR ADC in 40nm CMOS
Tai, H.-Y., Hu, Y.-S., Chen, H.-W., & Chen, H.-S. (2014) · 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC) · doi:10.1109/isscc.2014.6757397 · Cited by 234
An Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia Monitoring
Chen, Y.-P., Jeon, D., Lee, Y., Kim, Y., Foo, Z., Lee, I., Langhals, N. B., Kruger, G., Oral, H., Berenfeld, O., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364036 · Cited by 185
Harpe, P. J. A., Cantatore, E., & van Roermund, A. H. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2278471 · Cited by 175
Self-citationCharacterization of Human Body-Based Thermal and Vibration Energy Harvesting for Wearable Devices
Wahbah, M., Alhawari, M., Mohammad, B., Saleh, H., & Ismail, M. (2014) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2014.2337195 · Cited by 163
Research works printed but not linked: 4
- van elzakker, 2008, A 1.9 $\upmu$W 4.4 fJ/conversion-step 10b 1 MS/s charge-redistribution ADC, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 244
- tai, 2014, A 0.85 fJ/conversion-step 10b 200 kS/s subranging SAR ADC in 40 nm CMOS, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 196
- yan, 2014, A 680 nA fully integrated implantable ECG acquisition IC with analog feature extraction, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 418
- murmann, 2015, ADC Performance Survey 1997–2013
Cited by
Items 101–124 of 124
Mohammadi, E., Moeini-Manesh, M. M., Hafshejani, E. H., & Fotowat‐Ahmady, A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3678796 · Cited by 1
Next Generation Current Sense Interfaces for the IoT Era
Walsh, P. S., Kaprin, O., Maharyta, A., & Healy, M. (2022) · Springer eBooks · doi:10.1007/978-3-030-91741-8_8 · Cited by 1
A hybrid SAR ADC with input range extension
Qin, K., Hu, W., Xiang, Y., Yang, S., Cui, H., & Wang, M. (2024) · Microelectronics Journal · doi:10.1016/j.mejo.2024.106259 · Cited by 1
Chu, R., Li, J., & Lyu, H. (2024) · International Symposium on VLSI Technology, Systems and Applications (VLSI-TSA) · doi:10.1109/vlsitsa60681.2024.10546469 · Cited by 1
Sala, R. D., Amin, N. U., Aiello, O., Sidek, R. M., Rokhani, F. Z., & Tommasino, P. (2025) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas64648.2025.11107128 · Cited by 1
Preamble-Less Diversity Combining: Improved Energy-Efficiency in Sensor Networks
Nabeel, M., Amjad, M. S., & Dressler, F. (2018) · Globecom · doi:10.1109/glocom.2018.8647312 · Cited by 1
“Recent advances in technology helped miniaturizing the sensor nodes to target even more challenging applications [3].”
BackgroundChallenges and Opportunities in Wearable Biomedical Interfaces
Pamula, V. R., Hoof, C. A. V., & Verhelst, M. (2019) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-030-05870-8_1 · Cited by 1
Sensor Readout Circuit with Integrated Baseband Modulation for Low Power Backscatter Tags
Brönner, A., & Ellinger, F. (2018) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2018.8623936
“Compared to the state of the art, as shown in Table I, the chip area is reduced by the factor of 50, while the resolution and the sampling frequency is in the same range [3].”
BackgroundIntroduction to ECoG interfaces
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00008-8
Implantable Devices with Reconfigurable Biosensing Analog Front End
Arunthathi, J. M., & Prabhakar, R. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/561/1/012095
Shimamura, T., & Morimura, H. (2021) · IEICE Transactions on Electronics · doi:10.1587/transele.2020cdp0001
Threshold Detection ADC For Continuous Monitoring Applications
Fordymacka, A., & O’Connell, I. (2021) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas47672.2021.9531751
Breaking Unusual Barriers in Sensor Interfaces: From Minimum Energy to Ultimate Low Cost
Xin, H., Fattori, M., Harpe, P. J. A., & Cantatore, E. (2022) · Springer eBooks · doi:10.1007/978-3-030-91741-8_10
Self-citationPico-Ampere Current Biasing Platform for on-chip Tuning of Analog Blocks
Fierro, G., & Silveira, F. (2023) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas56464.2023.10108384
“As a measure to save area it is preferable to do without large valued resistors of [1], [5].”
BackgroundOverview of Design Challenges in High-Performance ExG Interfaces
Badami, K. M. H., Pons, M., Mavrogordatos, T. G., Fivaz, A., Persechini, P., Chételat, O., Ruëdi, P.-F., & Emery, S. (2012) · Springer eBooks · doi:10.1007/978-3-031-28912-5_1
A 6 bits 10 MS/s SAR ADC with multi-conversion dynamic amplifier
Lee, J.-K., & Oh, D. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20250204
Lin, X., Wang, B., Liu, L., Zhou, X., Yang, W., & Wang, H. (2025) · Circuits Systems and Signal Processing · doi:10.1007/s00034-025-03268-6
A 40dB Gain 100Hz-100kHz Band-Pass Filter
Li, Z., Li, P., Duan, Q., & Ding, Y. (2025) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin64977.2025.11279599
Favresse, S., Maistriaux, P., Harpe, P. J. A., Flandre, D., & Bol, D. (2025) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas67066.2025.00036 · Cited by 2
Self-citationSmall-Scale Biomedical Devices for Healthcare Applications
Majumder, S., Jiang, W., & Saha, S. (2026) · Springer eBooks · doi:10.1007/978-981-95-5519-2_2
AI based fatigue assessment system for athletes using smart textile wearables
Shen, D. (2024) · theses.fr (ABES) · doi:10.70675/e7faeb7cz94a9z48adzbf0fz56fe3448b863 · Cited by 7
Energy‐Aware Perturbation Optimization for Memristor‐Array Convolutional Neural Networks
Xu, A., Lu, L., Wu, Y., Guo, Y., Li, Y., Wang, Y., & Li, Q. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.70477 · Cited by 1
Metadata
- Authors
- Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M.
- Affiliations
- Eindhoven University of Technology (NL)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2016-01
- Volume
- 51
- Issue
- 1
- Pages
- 240-248
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2211705316
- Cited by
- 124
- References
- 22
- Citations by year
- 2026: 4 · 2025: 12 · 2024: 13 · 2023: 8 · 2022: 10 · 2021: 19 · 2020: 10 · 2019: 19 · 2018: 11 · 2017: 16 · 2016: 1
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- green
- research.tue.nl
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- Funders
- Stichting voor de Technische Wetenschappen
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- biomedical implants, Internet of Things, low-power amplifier, positive feedback, DC offset compensation, input impedance, successive approximation register ADC, clock generator, bias circuit, noise efficiency factor, figure of merit, ECG recording, 65 nm CMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.