A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS
Open accessThe DOI matches its Crossref record; 17 of the 22 references it cites were found in a registry or an index.
Abstract
Miniature mm3-sized sensor nodes have a very tight power budget, in particular, when a long operational lifetime is required, which is the case, e.g., for implantable devices or unobtrusive IoT nodes. This paper presents a fully integrated signal acquisition IC for these emerging applications. It integrates an amplifier with 32 dB gain and 370 Hz bandwidth that includes positive feedback to enhance input impedance and dc offset compensation. The IC includes also a 10 bit 1 kS/s SAR ADC as well as a clock generator and voltage and current biasing circuits. The overall system achieves an input noise of 27 μVrms, consumes 3 nW from a 0.6 V supply, occupies 0.20 mm2in 65 nm CMOS, and has a single-wire data interface. The amplifier achieves an noise-efficiency factor (NEF) of 2.1 and the ADC has a figure-of-merit (FoM) of 1.5 fJ/conversion-step. Measurements confirm reliable operation for supplies from 0.50 to 0.70 V and temperatures in the range of 0-85 °C. As an application example, an ECG recording is successfully performed with the system while a 0.69 mm2photodiode array provides its power supply in indoor lighting conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
A 10 b, 20 Msample/s, 35 mW pipeline A/D converter
Cho, T. B., & Gray, P. R. (1995) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.364429 · Cited by 633
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
A 6-bit 600-MS/s 5.3-mW Asynchronous ADC in 0.13-$\mu{\hbox{m}}$ CMOS
Chen, S.-W. M., & Brodersen, R. W. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884231 · Cited by 423
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
A 26 $\mu$W 8 bit 10 MS/s Asynchronous SAR ADC for Low Energy Radios
Harpe, P. J. A., Zhou, C., Bi, Y., van der Meijs, N. P., Wang, X., Philips, K., Dolmans, G., & de Groot, H. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143870 · Cited by 354
Self-citation11.2 A 0.85fJ/conversion-step 10b 200kS/s subranging SAR ADC in 40nm CMOS
Tai, H.-Y., Hu, Y.-S., Chen, H.-W., & Chen, H.-S. (2014) · 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC) · doi:10.1109/isscc.2014.6757397 · Cited by 234
An Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia Monitoring
Chen, Y.-P., Jeon, D., Lee, Y., Kim, Y., Foo, Z., Lee, I., Langhals, N. B., Kruger, G., Oral, H., Berenfeld, O., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364036 · Cited by 185
Harpe, P. J. A., Cantatore, E., & van Roermund, A. H. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2278471 · Cited by 175
Self-citationCharacterization of Human Body-Based Thermal and Vibration Energy Harvesting for Wearable Devices
Wahbah, M., Alhawari, M., Mohammad, B., Saleh, H., & Ismail, M. (2014) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2014.2337195 · Cited by 163
Research works printed but not linked: 4
- van elzakker, 2008, A 1.9 $\upmu$W 4.4 fJ/conversion-step 10b 1 MS/s charge-redistribution ADC, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 244
- tai, 2014, A 0.85 fJ/conversion-step 10b 200 kS/s subranging SAR ADC in 40 nm CMOS, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 196
- yan, 2014, A 680 nA fully integrated implantable ECG acquisition IC with analog feature extraction, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 418
- murmann, 2015, ADC Performance Survey 1997–2013
Cited by
Hardware implementation of memristor-based artificial neural networks
Aguirre, F., Sebastian, A., Le Gallo, M., Song, W., Wang, T., Yang, J. J., Lu, W., Chang, M.-F., Ielmini, D., Yang, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-45670-9 · Cited by 564
“150 – 152, increasing 1-bit resolution or increasing the throughput by doubling the sampling frequency results in a 4× increase in power consumption (particularly for highly scaled CMOS technology nodes, where the power consumption is usually bounded by the thermal noise 153 ).”
Amirsoleimani, A., Alibart, F., Yon, V., Xu, J., Pazhouhandeh, M. R., Ecoffey, S., Beilliard, Y., Genov, R., & Drouin, D. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000115 · Cited by 216
Prolonged energy harvesting for ingestible devices
Nadeau, P., El-Damak, D., Glettig, D., Kong, Y. L., Mo, S., Cleveland, C., Booth, L., Roxhed, N., Langer, R., Chandrakasan, A. P., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0022 · Cited by 219
Noncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L., Marinov, O., Chen, C.-H., Mondal, T., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 165
The Extreme Edge at the Bottom of the Internet of Things: A Review
Portilla, J., Mujica, G., Lee, J., & Riesgo, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2891911 · Cited by 142
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
Ultra-Low Power QRS Detection and ECG Compression Architecture for IoT Healthcare Devices
Tekeste, T., Saleh, H. H., Mohammad, B. S., & Ismail, M. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2867746 · Cited by 112
“3nW as in [8]) could be integrated to the proposed digital processor”
BackgroundCosoli, G., Spinsante, S., Scardulla, F., D’Acquisto, L., & Scalise, L. (2021) · Measurement · doi:10.1016/j.measurement.2021.109243 · Cited by 110
Yang, M., Yeh, C.-H., Zhou, Y., Cerqueira, J. P., Lazar, A. A., & Seok, M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2894360 · Cited by 99
“However, in the audio frequency range, this requires the use of pseudo-resistors whose resistance is highly susceptible to PVT variations, and consequently the associated high-pass corner frequency and the recovery time of the amplifier from any common-mode disturbance are poorly defined [33].”
BackgroundA 13.9-nA ECG Amplifier Achieving 0.86/0.99 NEF/PEF Using AC-Coupled OTA-Stacking
Mondal, S., & Hall, D. A. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2957193 · Cited by 92
“Ultra-low-power AFEs exhibiting 1400- and 250-nV/ √ Hz noise floors have hence been reported in [1] and [2], respectively, and are applicable for arrhythmia detections.”
BackgroundMethodResultInfluentialYaul, F. M., & Chandrakasan, A. P. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2746778 · Cited by 84
A Low Power 12-bit 1-kS/s SAR ADC for Biomedical Signal Processing
Mao, W., Li, Y., Heng, C.-H., & Lian, Y. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2859837 · Cited by 77
“and [22], the ADCs are designed using 65-nm process.”
MethodXin, H., Andraud, M., Baltus, P. G. M., Cantatore, E., & Harpe, P. J. A. (2018) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2018.2827883 · Cited by 70
Self-citationIoT Based Heart Activity Monitoring Using Inductive Sensors
Brezulianu, A., Geman, O., Zbancioc, M. D., Hăgan, M., Aghion, C., Hemanth, D. J., & Sơn, L. H. (2019) · Sensors · doi:10.3390/s19153284 · Cited by 69
Jeong, S., Chen, Y., Jang, T., Tsai, J. M.-L., Blaauw, D. T., Kim, H.-S., & Sylvester, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2728787 · Cited by 61
Oh, S., Kim, H.-S., Sylvester, D., Cho, M., Shi, Z., Lim, J., Kim, Y., Jeong, S., Chen, Y., Rothe, R., et al. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2936756 · Cited by 55
Hsu, Y.-P., Liu, Z., & Hella, M. M. (2019) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2019.2943904 · Cited by 58
“amplifier for the SRMC filter, where the first stage formed of M0-5 has a complementary input stage, and the second stage formed of M6-9 realizes an output buffer [5], [11], [15], [16].”
BackgroundBhamra, H., Lynch, J., Ward, M. P., & Irazoqui, P. P. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2017.2714171 · Cited by 60
Wang, Z., Liu, Y., Zhou, P., Tan, Z., Fan, H., Zhang, Y., Shen, L., Ru, J., Wang, Y., Ye, L., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113257 · Cited by 51
An Energy-Efficient DAC Switching Method for SAR ADCs
Yousefi, T., Dabbaghian, A., & Yavari, M. (2017) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2017.2676048 · Cited by 46
Zhao, M., Zhao, Y., Zhang, H., Hu, Y., Bao, Y., Ye, L., Qu, W., & Tan, Z. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3123261 · Cited by 45
A Dual-Loop Eight-Channel ECG Recording System With Fast Settling Mode for 12-Lead Applications
Zeng, L., Liu, B., & Heng, C.-H. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2903471 · Cited by 45
“In [15], a sub-μW system is implemented, at the expense of”
BackgroundMethodAll 3D Printed Stretchable Piezoelectric Nanogenerator for Self-Powered Sensor Application
Zhou, X., Parida, K., Halevi, O., Magdassi, S., & Lee, P. S. (2020) · Sensors · doi:10.3390/s20236748 · Cited by 44
Wang, Z., Zhang, H., Zhang, Y., Shen, L., Ru, J., Fan, H., Tan, Z., Wang, Y., Ye, L., & Huang, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3074636 · Cited by 43
A 0.1-nW–1-$\mu$ W Energy-Efficient All-Dynamic Versatile Capacitance-to-Digital Converter
Xin, H., Andraud, M., Baltus, P. G. M., Cantatore, E., & Harpe, P. J. A. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2902754 · Cited by 47
“This paper presented a versatile, energy efficient, and low-power CDC with only dynamic circuits, including a single-armed capacitive bridge and a 10-b asynchronous SAR ADC.”
BackgroundMethodInfluentialSelf-citationA 0.6V 3.8μW ECG/bio-impedance monitoring IC for disposable health patch in 40nm CMOS
Xu, J., Lin, Q., Ding, M., Li, Y., Hoof, C. A. V., Serdijn, W. A., & Helleputte, N. V. (2018) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2018.8357025 · Cited by 39
“To improve power-efficiency of the CCIA, the core amplifier is based on an inverter-based input stage [3] (Fig.”
BackgroundMethodGraphene oxide: Nylon ECG sensors for wearable IoT healthcare—nanomaterial and SoC interface
Hallfors, N., Alhawari, M., Jaoudé, M. A., Kifle, Y., Saleh, H. H., Liao, K., Ismail, M., & Isakovic, A. F. (2018) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-018-1116-6 · Cited by 45
Low-Voltage, Low-Area, nW-Power CMOS Digital-Based Biosignal Amplifier
Toledo, P., Crovetti, P., Klimach, H., Musolino, F., & Bampi, S. (2022) · IEEE Access · doi:10.1109/access.2022.3168603 · Cited by 44
“3, the BioDIGOTA presented here is able to work properly at the lowest VDD (2× lower than [12], [13]), at the lowest silicon area (3.”
BackgroundCurrent-Efficient Preamplifier Architecture for CMRR Sensitive Neural Recording Applications
Oreggioni, J., Caputi, A. A., & Silveira, F. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2826720 · Cited by 38
A 0.36-V 5-MS/s Time-Mode Flash ADC With Dickson-Charge-Pump-Based Comparators in 28-nm CMOS
Esmailiyan, A., Schembari, F., & Staszewski, R. B. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2969804 · Cited by 34
Zhang, S., Zhou, X., Gao, C., & Li, Q. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3010816 · Cited by 33
A 0.3 V Rail-to-Rail Ultra-Low-Power OTA with Improved Bandwidth and Slew Rate
Centurelli, F., Sala, R. D., Monsurrò, P., Scotti, G., & Trifiletti, A. (2021) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea11020019 · Cited by 33
Agarwala, R., Wang, P., Bishop, H. L., Dissanayake, A., & Calhoun, B. H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3057229 · Cited by 33
“Compared with dedicated low-power ECG channels [17] or high-power ECG channels in multi-modal sensor interface designs [9], [11], this ECG channel has the drawback of relatively bad noise performance.”
BackgroundA 0.3 V, Rail-to-Rail, Ultralow-Power, Non-Tailed, Body-Driven, Sub-Threshold Amplifier
Centurelli, F., Sala, R. D., Scotti, G., & Trifiletti, A. (2021) · Applied Sciences · doi:10.3390/app11062528 · Cited by 32
Jeong, S., Chen, Y., Jang, T., Tsai, J. M.-L., Blaauw, D. T., Kim, H.-S., & Sylvester, D. (2017) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2017.7870411 · Cited by 31
Cai, L., Zhi, H., Yang, K., Qian, J., Yan, Z., Zhu, L., Chen, C., Wang, X., & Shan, W. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3339528 · Cited by 32
Sala, R. D., Centurelli, F., Scotti, G., Tommasino, P., & Trifiletti, A. (2022) · Electronics · doi:10.3390/electronics11233838 · Cited by 28
A Tree-Based Architecture for High-Performance Ultra-Low-Voltage Amplifiers
Centurelli, F., Sala, R. D., Monsurrò, P., Scotti, G., & Trifiletti, A. (2022) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea12010012 · Cited by 27
Shen, D., Tao, X., Končar, V., & Wang, J. (2023) · IEEE Access · doi:10.1109/access.2023.3322925 · Cited by 30
Analog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 37
Pham, X. T., Nguyen, N. T., Nguyen, V.-N., & Lee, J. (2021) · IEEE Access · doi:10.1109/access.2021.3087737 · Cited by 25
“The CM output voltage of the input pair can be directly affected by VTH, which can shift more than 100 mV with the PVT variations [32].”
BackgroundA Nyquist Rate SAR ADC Employing Incremental Sigma Delta DAC Achieving Peak SFDR = 107 dB at 80 kS/s
AlMarashli, A., Anders, J., Becker, J., & Ortmanns, M. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2776299 · Cited by 24
“Therefore, the most power-efficient SAR ADCs employ CDACs at moderate to low speed [1]–[3] and moderate to low resolution.”
BackgroundMethodA 0.006 mm2 1.2 $\mu$ W Analog-to-Time Converter for Asynchronous Bio-Sensors
Leene, L. B., & Constandinou, T. G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2850918 · Cited by 29
432 nW per Channel 130 nV/rtHz ECG Acquisition Front End With Multifrequency Chopping
Khatavkar, P., & Aniruddhan, S. (2019) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2019.2910202 · Cited by 24
Non-corrosive, low-toxicity gel-based microbattery from organic and organometallic molecules
Crespilho, F. N., Sedenho, G. C., Porcellinis, D. D., Kerr, E. F., Granados-Fócil, S., Gordon, R. G., & Aziz, M. J. (2019) · Journal of Materials Chemistry A · doi:10.1039/c9ta08685d · Cited by 25
A 1.2nW Analog Electrocardiogram Processor Achieving a 99.63% QRS Complex Detection Sensitivity
Güngör, C. B., Mercier, P. P., & Töreyin, H. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3092729 · Cited by 21
Valtierra, J. L., Delgado‐Restituto, M., Fiorelli, R., & Rodriguez-Vazquez, A. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2968087 · Cited by 22
“The use of pseudoresistors has been avoided since it has been suggested that they exhibit much larger variability than active feedback [32].”
BackgroundFrom Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 25
Li, H., Shen, Y., Cantatore, E., & Harpe, P. J. A. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3227678 · Cited by 19
“The common-mode feedback (CMFB) circuitry is the same as in [22].”
Self-citationRothe, R., Cho, M., Choo, K. D., Jeong, S., Oh, S., Lee, J., Sylvester, D., & Blaauw, D. T. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3135899 · Cited by 20
0.3 V ultra-low power sensor interface for EMG
Orguc, S., Khurana, H. S., Lee, H.-S., & Chandrakasan, A. P. (2017) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2017.8094565 · Cited by 18
“In the low-voltage/low-power domain, recently published work includes a 3nW signal acquisition analog front end (AFE) [1], an implantable 64nW ECG-Monitoring IC [2], a sub-µW chopper amplifier IC [3], and a power-efficient neural recording IC [4], which use supply voltages of 0.45V or higher.”
BackgroundInfluentialHigh-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Kuo, H.-L., Lu, C., & Chen, P. (2021) · IEEE Access · doi:10.1109/access.2020.3048979 · Cited by 16
“In sensor applications, themost widely used ADC resolution is 8–12 bits [1]–[6].”
MethodReal time system on chip based wearable cardiac activity monitoring sensor
Jain, A., Singh, M., & Singh, B. (2022) · Measurement: Sensors · doi:10.1016/j.measen.2022.100523 · Cited by 15
Ng, K. A., Zhang, L., Wu, H., Tang, T., & Yoo, J. (2024) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2024.3391169 · Cited by 16
Güngör, C. B., Mercier, P. P., & Töreyin, H. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3235786 · Cited by 13
“1 nW [6] for the AFE and ADC, respectively.”
BackgroundMatched-Routing Common-Centroid 3-D MOM Capacitors for Low-Power Data Converters
Chou, P.-Y., Chen, N.-C., Lin, M. P.-H., & Graeb, H. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2017.2687980 · Cited by 14
“scales down to that in [8], the unit capacitance is reduced from 0.”
BackgroundXu, X., Ye, S., Luan, Y., Gao, J., Li, J., Cui, J., Zhang, H., Huang, R., Shen, L., & Ye, L. (2024) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49657.2024.10454416 · Cited by 12
A Low-Noise CTIA-based pixel with CDS for SWIR Focal Plane Arrays
Zhuo, Y., Lu, W., Yu, S., Zhou, Y., Kong, J., Zhang, Y., & Chen, Z. (2021) · International Conference on Integrated Circuits and Microsystems (ICICM) · doi:10.1109/icicm54364.2021.9660360 · Cited by 12
The Basics of Healthcare IoT: Data Acquisition, Medical Devices, Instrumentations and Measurements
Arefin, A. S. M. S., Nahiyan, K. M. T., & Rabbani, M. (2019) · Intelligent systems reference library · doi:10.1007/978-3-030-23983-1_1 · Cited by 13
Self-Biased Ultralow Power Current-Reused Neural Amplifier With On-Chip Analog Spike Detections
Kim, J., & Ko, H. (2019) · IEEE Access · doi:10.1109/access.2019.2933674 · Cited by 14
“The previously reported current-reuse amplifiers require additional biasing circuit [23], [27]–[30].”
BackgroundResultXu, Q., Li, G., Liu, Y., Luo, F. C., & Xiao, Z. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3363130 · Cited by 11
Energy-efficient, area-efficient, high-accuracy and low-complexity switching scheme for SAR ADC
Hu, Y., Yi, Z., Zhi-hong, H., & Li, B. (2017) · IEICE Electronics Express · doi:10.1587/elex.14.20170428 · Cited by 10
“1 Introduction In recent years, successive-approximation register (SAR) analogue-to-digital converters (ADCs) have been preferred for low-power applications [1, 2, 3].”
BackgroundA 6-nW 0.0013-mm² ILO Bandpass Filter for Time-Based Feature Extraction
Goux, N., Casanova, J.-B., Pillonnet, G., & Badets, F. (2020) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2020.3016716 · Cited by 10
“Digital feature extraction uses dedicated ICs, using the classical front end and ADC architecture [1], [2], which allows to decrease dramatically the power consumption to some tenth of nW, but result in a limited input bandwidth of 500 Hz for [2], which does not cover the full audio band and is not compatible with VAD.”
MethodXin, H., Baltus, P. G. M., Cantatore, E., & Harpe, P. J. A. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3119541 · Cited by 9
“A 10b asynchronous SAR ADC as in [14] is used, such that a single clock edge enables the entire ADC operation.”
BackgroundMethodInfluentialSelf-citationMEMS microphone fully-integrated CMOS cap-less preamplifiers
Croce, M., Berti, C. D., Crespi, L., Malcovati, P., & Baschirotto, A. (2017) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime.2017.7974101 · Cited by 9
“The concept of an off-transistor connected between the opamp input nodes and a fixed voltage has been implemented in other works in different ways, like in [9], [10].”
BackgroundDesign of a 16-bit 500-MS/s SAR-ADC for low-power application
Singh, T., & Tripathi, S. L. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-85172-5.00011-3 · Cited by 9
A 672-nW, 670-nVrms ECG Acquisition AFE With Noise-Tolerant Heartbeat Detector
Zeng, Y., Li, Z., Chen, W., Zhou, W., Bao, Y., Chen, Y., & Li, Y. (2023) · IEEE Open Journal of Circuits and Systems · doi:10.1109/ojcas.2023.3237839 · Cited by 8
A 10.5µW programmable SAR ADC Frontend with SC Preamplifier for Low-Power IoT Sensor Nodes
Jotschke, M., Ossa, W. C., Reich, T., & Mayr, C. (2020) · IEEE World Forum on Internet of Things (WF-IoT) · doi:10.1109/wf-iot48130.2020.9221058 · Cited by 8
Mittal, A., Xu, Z., Du, K., Kumar, S. S., & Shrivastava, A. (2024) · IEEE Internet of Things Journal · doi:10.1109/jiot.2024.3416896 · Cited by 7
Ultra-Low Power Analog-Digital Converters for IoT
Harpe, P. J. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-51482-6_13 · Cited by 7
Self-citationBioelectronic devices: Gut-powered ingestible biosensors
Menciassi, A. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0050 · Cited by 7
ECG analog front end circuit-A review
Wang, S., Yang, H., Jiao, G., Ren, M., & Li, X. (2026) · Measurement · doi:10.1016/j.measurement.2026.120566 · Cited by 6
Toledo, P., Klimach, H., Bampi, S., & Crovetti, P. (2021) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea52024.2021.9478709 · Cited by 7
Crovetti, P., Rubino, R., Toledo, P., Musolino, F., Klimach, H., Chen, Y., & Richelli, A. (2022) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc55480.2022.9911357 · Cited by 6
“In this scenario, ACcoupled acquisition front-ends (AFEs) with < 10 nW power [3], [4], [5] and 0.”
BackgroundPu, N., Wu, N., Abubakar, S. M., Yang, Y., Liu, X., Pan, S., Guo, Y., Wen, J., Wang, Z., & Jiang, H. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3360886 · Cited by 6
A 9.6 nW, 8-Bit, 100 S/s Envelope-to-Digital Converter for Respiratory Monitoring
Shi, E., de Godoy, D., Kinget, P. R., & Pun, K. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2922661 · Cited by 6
Berkol, G., Baltus, P. G. M., Harpe, P. J. A., & Cantatore, E. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3049246 · Cited by 5
“2) Missed Detection Rate (MDR) Measurements: In order to reduce the demodulation complexity in the digital domain and to save power, the WURX digital output is used in a digital threshold detector, where a threshold around the DC output code of the ADC is applied to wake-up the node.”
MethodInfluentialSelf-citationWen, Y., Liu, W., Li, W., Zheng, B., Li, D., & Feng, Q. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20250097 · Cited by 4
Xu, X., Ye, S., Luan, Y., Gao, J., Li, J., Cui, J., & Shen, L. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3564316 · Cited by 6
A 0.5V time-domain instrumentation circuit with clocked and unclocked ΔΣ operation
Leene, L. B., & Constandinou, T. G. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050956 · Cited by 4
Berkol, G., Baltus, P. G. M., Harpe, P. J. A., & Cantatore, E. (2020) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2020.3018791 · Cited by 4
“After the highfrequency harmonics of the mixer are filtered by the BBAMP, the signal is converted to the digital domain by a 10-bit SAR ADC, which has been presented in detail in [6].”
MethodSelf-citationA 12-bit, 100 kS/s, PVT robust SAR ADC in 65 nm CMOS process
Ahmadlou, M., Dündar, G., & Doğan, H. (2024) · Microelectronics Journal · doi:10.1016/j.mejo.2024.106258 · Cited by 5
A −81.6dBm Sensitivity Ultrasound Transceiver in 65nm CMOS for Symmetrical Data-Links
Berkol, G., Baltus, P. G. M., Harpe, P. J. A., & Cantatore, E. (2019) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2019.8902921 · Cited by 4
“However, by reviewing relevant prior art [7], [9] these overheads can be estimated to be much lower than the RX power and thus will not significantly change the overall results.”
BackgroundMethodSelf-citationExperimental evaluation of receive diversity techniques in distributed sensor networks
Nabeel, M., & Dressler, F. (2019) · Ad Hoc Networks · doi:10.1016/j.adhoc.2019.102066 · Cited by 4
“Such new applications now require further minimization of the sensor node size, hence, researchers are making efforts to cope with these challenges [20].”
BackgroundLi, J., Chu, R., Li, Z., & Lyu, H. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558047 · Cited by 4
Headphone Amplifier and its Layout for Education for High School Student
Umezaki, C., Yoshitomi, T., Ishikawa, Y., Shimizu, A., Noguchi, T., & Fukai, S. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702788 · Cited by 3
“Analog IC designers are required due to growing of IoT and Automotive [1].”
BackgroundA 0.3-μW, 2.3-μVrms Bio-AFE With Auto-Calibrated Embedded DC-Servo-Loop
Bao, Y., Chen, Y., Li, Y., & Zeng, Y. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388608 · Cited by 2
A 0.3 V OTA with Enhanced CMRR and High Robustness to PVT Variations
Sala, R. D., Centurelli, F., Scotti, G., & Trifiletti, A. (2024) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea14020021 · Cited by 2
Sala, R. D., Shokri, R., Aiello, O., Caviglia, D. D., & Scotti, G. (2025) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas64648.2025.11107004 · Cited by 2
Cap-less audio preamplifiers for silicon microphones
Croce, M., Berti, C. D., Crespi, L., Malcovati, P., & Baschirotto, A. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808720 · Cited by 2
“In other implementations based on this concept [8], [9], the off-transistor is connected between a fixed voltage and the + R1”
BackgroundAdvances in Biomedical Sensor Systems for Wearable Health
Helleputte, N. V., Xu, J., Ha, H., van Wegberg, R., Song, S., Stanzione, S., Zaliasl, S., van den Hoven, R., Qiu, W., Xin, H., et al. (2017) · Springer eBooks · doi:10.1007/978-3-319-61285-0_7 · Cited by 2
Bol, D., & de Streel, G. (2020) · Integrated circuits and systems · doi:10.1007/978-3-030-39496-7_9 · Cited by 2
Threshold Switching Enabled Sub-pW-Leakage, Hysteresis-Free Circuits
Cheng, B., Emboras, A., Passerini, E., Lewerenz, M., Koch, U., Wu, L., Liao, J., Ducry, F., Aeschlimann, J., Jang, T., et al. (2021) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2021.3075393 · Cited by 3
Zhou, S., Chen, X., Kim, K., & Liu, S. (2023) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas57966.2023.10168561 · Cited by 2
“The input features to the network (i.e. ADC output codes) are first compressed logarithmically and then normalized using per-channel mean and standard deviation calculated from the entire GSCD training set.”
MethodInfluentialA 2.2 μW analog front-end for multichannel neural recording
Valtierra, J. L., Delgado‐Restituto, M., & Rodriguez-Vazquez, A. (2017) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas.2017.7948085 · Cited by 2
“3(a), differently sized and biased according to its function as introduced by [8].”
BackgroundA High-Impedance 3-MOSFET Pseudo-Resistor for Instrumentation Amplifiers of Biomedical Sensors
Yan, F., Sun, K., Li, Z., Guan, J., Xiong, B., & Liu, J. (2023) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas60141.2023.00038 · Cited by 1
Sala, R. D., Aiello, O., & Scotti, G. (2025) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas64004.2025.10966355 · Cited by 1
Wang, Y., Zhan, Y., Qiao, S., & Hu, X. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20250243 · Cited by 1
Hao, Y., Fan, H., Lian, Y., & Chen, M. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3612895 · Cited by 1
Metadata
- Authors
- Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M.
- Affiliations
- Eindhoven University of Technology (NL)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2016-01
- Volume
- 51
- Issue
- 1
- Pages
- 240-248
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2211705316
- Cited by
- 124
- References
- 22
- Citations by year
- 2026: 4 · 2025: 12 · 2024: 13 · 2023: 8 · 2022: 10 · 2021: 19 · 2020: 10 · 2019: 19 · 2018: 11 · 2017: 16 · 2016: 1
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- green
- research.tue.nl
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- Funders
- Stichting voor de Technische Wetenschappen
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- biomedical implants, Internet of Things, low-power amplifier, positive feedback, DC offset compensation, input impedance, successive approximation register ADC, clock generator, bias circuit, noise efficiency factor, figure of merit, ECG recording, 65 nm CMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.