Battery-less Tri-band-Radio Neuro-monitor and Responsive Neurostimulator for Diagnostics and Treatment of Neurological Disorders
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A 0.13 μm CMOS system on a chip (SoC) for 64 channel neuroelectrical monitoring and responsive neurostimulation is presented. The direct-coupled chopper-stabilized neural recording front end rejects up to ±50 mV input dc offset using an in-channel digitally assisted feedback loop. It yields a compact 0.018 mm2integration area and 4.2 μVrms integrated input-referred noise over 1 Hz to 1 kHz frequency range. A multiplying specific absorption rate (SAR) ADC in each channel calibrates channel-to-channel gain mismatch. A multicore low-power DSP performs synchrony-based neurological event detection and triggers a subset of 64 programmable current-mode stimulators for subsequent neuromodulation. Triple-band FSK/ultra-wideband (UWB) wireless transmitters communicate to receivers located at 10 cm to 10 m distance from the SoC with data rates from 1.2 to 45 Mbps. An inductive link that operates at 1.5 MHz, provides power and is also used to communicate commands to an on-chip ASK receiver. The chip occupies 16 mm2while consuming 2.17 and 5.8 mW with UWB and FSK transmitters, respectively. Efficacy of the SoC is assessed using a rat model of temporal lobe epilepsy characterized by spontaneous seizures. It exhibits an average seizure detection sensitivity and specificity of 87% and 95%, respectively, with over 78% of all seizures aborted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“The overall size and power consumption should be minimized to follow the safety guidelines [17], [18].”
BackgroundA low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“The stimulation current and pulsewidth were chosen according to safety considerations [46] (three times lower than the maximum deliverable charge per phase [13]).”
MethodMuller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Energy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165
Cited by
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“The signals at the recording front-end electrodes excluding the common-mode interferers can be categorized as follows: 1) the neural signal; 2) the electrode dc offset (EDO); and 3) the stimulation artifacts as shown in Fig.”
BackgroundSelf-citationDabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936327 · Cited by 56
Self-citationAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Lyu, L., Ye, D., Xu, R., Mu, G., Zhao, H., Xiang, Y., Tu, Y., Zhang, Y., & Shi, C.-J. R. (2020) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2020.2982208 · Cited by 14
Metadata
- Authors
- Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Perez Velazquez, J. L., & Genov, R.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2016-05
- Volume
- 51
- Issue
- 5
- Pages
- 1274-1289
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2323274874
- Cited by
- 116
- References
- 6
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Battery-less Tri-band-Radio Neuro-monitor and Responsive Neurostimulator for Diagnostics and Treatment of Neurological Disorders. https://app.cochat.ai/papers/10.1109/jssc.2016.2528999
- The paper
- Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Perez Velazquez, J. L., & Genov, R. (2016). Battery-less Tri-band-Radio Neuro-monitor and Responsive Neurostimulator for Diagnostics and Treatment of Neurological Disorders. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2016.2528999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.