Mass Classification in Mammograms Using Selected Geometry and Texture Features, and a New SVM-Based Feature Selection Method
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Masses are the primary indications of breast cancer in mammograms, and it is important to classify them as benign or malignant. Benign and malignant masses differ in geometry and texture characteristics. However, not every geometry and texture feature that is extracted contributes to the improvement of classification accuracy; thus, to select the best features from a set is important. In this paper, we examine the feature selection methods for mass classification. We integrate a support vector machine (SVM)-based recursive feature elimination (SVM-RFE) procedure with a normalized mutual information feature selection (NMIFS) to avoid their singular disadvantages (the redundancy in the selected features of the SVM-RFE and the unoptimized classifier for the NMIFS) while retaining their advantages, and we propose a new feature selection method, which is called the SVM-RFE with an NMIFS filter (SRN). In addition to feature selection, we also study the initialization of mass segmentation. Different initialization methods are investigated, and we propose a fuzzy c-means (FCM) clustering, with spatial constraints as the initialization step. In the experiments, 826 regions of interest (ROIs) from the Digital Database for Screening Mammography were used. All 826 were used in the classification experiments, and 413 ROIs were used in the feature selection experiments. Different feature selection methods, including F-score, Relief, SVM-RFE, SVM-RFE with a minimum redundancy-maximum relevance (mRMR) filter [SVM-RFE (mRMR)], and SRN, were used to select features and to compare mass classification results using the selected features. In the classification experiments, the linear discriminant analysis and the SVM classifiers were investigated. The accuracy that is obtained with the SVM classifier using the selected features obtained by the F-score, Relief, SVM-RFE, SVM-RFE (mRMR), and SRN methods are 88%, 88%, 90%, 91%, and 93%, respectively, with a tenfold cross-validation procedure, and 91%, 89%, 92%, 92%, and 94%, respectively, with a leave-one-out (LOO) scheme. We also compared the performance of the different feature selection methods using the receiver operating characteristic analysis and the areas under the curve (AUCs). The AUCs for the F-score, Relief, SVM-RFE, SVM-RFE (mRMR), and SRN methods are 0.9014, 0.8916, 0.9121, 0.9236, and 0.9439, respectively, with a tenfold cross-validation procedure, and are 0.9312, 0.9178, 0.9324, 0.9413, and 0.9615, respectively, with a LOO scheme. Both the accuracy and AUC values show that the proposed SRN feature selection method has the best performance. In addition to the accuracy and the AUC, we also measured the significance between the two best feature selection methods, i.e., the SVM-RFE (mRMR) and the proposed SRN method. Experimental results show that the proposed SRN method is significantly more accurate than the SVM-RFE (mRMR) (p = 0.011).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · cited 1×
“For the SVM implementation, we used a library for SVM (LIBSVM) toolbox [41].”
MethodTextural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879 · cited 1×
“For the tenfold cross validation, the Az value is calculated with the averaged ROC curve values from ten runs, with the vertical averaging approach detailed in [43].”
MethodKass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070 · cited 1×
“a level set, which originates from the active contour model (snake) [26], [27].”
BackgroundAn Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Peng, H., Long, F., & Ding, C. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.159 · Cited by 10,544 · cited 7×
“Specifically, the mRMR method [20] has been integrated into the SVM-RFE [17] to reduce the redundancy.”
BackgroundMethodInfluentialChan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304 · cited 1×
“a level set, which originates from the active contour model (snake) [26], [27].”
BackgroundGene selection for cancer classification using support vector machines
Guyon, I., Weston, J., Barnhill, S., & Vapnik, V. (2002) · Machine Learning · doi:10.1023/a:1012487302797 · Cited by 9,954 · cited 6×
“Specifically, the mRMR method [20] has been integrated into the SVM-RFE [17] to reduce the redundancy.”
MethodInfluentialWrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947 · cited 2×
“Many methods for feature selection have been proposed [16].”
MethodHanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
FCM: The fuzzy c-means clustering algorithm
Bezdek, J. C., Ehrlich, R., & Full, W. (1984) · Computers & Geosciences · doi:10.1016/0098-3004(84)90020-7 · Cited by 6,608 · cited 13×
“The performance of this method was evaluated by comparing the sFCM results obtained from 40 images with the results obtained from the manual segmentation of the same images.”
MethodInfluentialComparing images using the Hausdorff distance
Huttenlocher, D. P., Klanderman, G. A., & Rucklidge, W. J. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.232073 · Cited by 4,545 · cited 3×
“For the quantitative evaluation of the segmentation results, we used Dice coefficient D, which is one of a number of measures of the extent of spatial overlap between two binary images [39] and is a widely used measure for segmentation evaluation.”
BackgroundMethodInfluentialPattern Classification and Scene Analysis.
Clarke, M. R. B., Duda, R. O., & Hart, P. E. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344977 · Cited by 3,222
Theoretical and Empirical Analysis of ReliefF and RReliefF
Robnik-Šikonja, M., & Kononenko, I. (2003) · Machine Learning · doi:10.1023/a:1025667309714 · Cited by 3,025 · cited 2×
“For the feature selection methods, we investigate the F-score [23], Relief [24], SVM-RFE [17], SVM-RFE with a minimum redundancy–maximum relevance (mRMR) filter [SVM-RFE (mRMR)] methods [19], and the proposed SVM-RFE with an NMI feature selection (NMIFS) filter (SRN) method.”
MethodMinimization of Region-Scalable Fitting Energy for Image Segmentation
Li, C., Kao, C.-Y., Gore, J. C., & Ding, Z. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2002304 · Cited by 1,721 · cited 1×
“Traditionally, a signed distance function is used [22], [28].”
A modified Hausdorff distance for object matching
Dubuisson, M.-P., & Jain, A. K. (2002) · Proceedings of 12th International Conference on Pattern Recognition · doi:10.1109/icpr.1994.576361 · Cited by 1,464 · cited 1×
“liers, we used a modified Hausdorff distance (MHD) [40].”
MethodFuzzy c-means clustering with spatial information for image segmentation
Chuang, K.-S., Tzeng, H.-L., Chen, S., Wu, J., & Chen, T.-J. (2006) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2005.10.001 · Cited by 1,323 · cited 2×
“use the spatial FCM (sFCM) that is developed in [21], which incorporates the spatial information into the fuzzy membership function.”
MethodNormalized Mutual Information Feature Selection
Estevez, P. A., Tesmer, M., Perez, C. A., & Zurada, J. M. (2009) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2008.2005601 · Cited by 1,288 · cited 6×
“[18] have proposed the NMIFS method to overcome this problem.”
BackgroundMethodInfluentialTHE DIGITAL DATABASE FOR SCREENING MAMMOGRAPHY
Heath, M. D., Bowyer, K. W., Kopans, D. B., & Moore, R. M. (2007) · Cited by 1,017
Combining SVMs with Various Feature Selection Strategies
Chen, Y.-W., & Lin, C.-J. (2008) · Studies in Fuzziness and Soft Computing · doi:10.1007/978-3-540-35488-8_13 · Cited by 980 · cited 2×
“For the feature selection methods, we investigate the F-score [23], Relief [24], SVM-RFE [17], SVM-RFE with a minimum redundancy–maximum relevance (mRMR) filter [SVM-RFE (mRMR)] methods [19], and the proposed SVM-RFE with an NMI feature selection (NMIFS) filter (SRN) method.”
MethodLee, C. H., Dershaw, D. D., Kopans, D., Evans, P., Monsees, B., Monticciolo, D., Brenner, R. J., Bassett, L., Berg, W., Feig, S., et al. (2010) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.09.022 · Cited by 809 · cited 1×
“Imaging technologies have played an important role in early detection [2], and mammography has been widely accepted as a diagnostic and screening tool for early breast cancer detection.”
MethodComputer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619 · cited 1×
“attention [8], further effort must be put on the investigation of related key technologies.”
BackgroundSelf-citationMandelblatt, J. S., Cronin, K. A., Bailey, S., Berry, D. A., de Koning, H. J., Draisma, G., Huang, H., Lee, S. J., Munsell, M., Plevritis, S. K., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00010 · Cited by 605
SVM-RFE With MRMR Filter for Gene Selection
Mundra, P. A., & Rajapakse, J. C. (2010) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2009.2035284 · Cited by 332 · cited 8×
“The proposed SRN feature selection method is similar to the method in [19], except that (10) is used to replace (7).”
BackgroundMethodInfluentialGradient and texture analysis for the classification of mammographic masses
Desautels, J. E. L., Rangayyan, R., & Mudigonda, N. R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887618 · Cited by 281 · cited 5×
“to discriminate the benign and malignant masses [10].”
BackgroundMethodInfluentialScreening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006) · Radiology · doi:10.1148/radiol.2392042121 · Cited by 218 · cited 1×
“A recent report [7] demonstrates that the adoption of CAD improved the detection of breast cancer by 7.”
BackgroundSahiner, B., Chan, H.-P., Petrick, N., Helvie, M. A., & Goodsitt, M. M. (1998) · Medical Physics · doi:10.1118/1.598228 · Cited by 205 · cited 1×
“[14] utilized a rubber band straightening transform to characterize mammographic masses as malignant or benign, and Eltoukhy et al.”
MethodBoundary modelling and shape analysis methods for classification of mammographic masses
Rangayyan, R. M., Mudigonda, N. R., & Desautels, J. E. L. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345742 · Cited by 198 · cited 1×
“In [9], the mass classification using gradients was investigated.”
MethodSahiner, B., Chan, H., Petrick, N., Helvie, M. A., & Hadjiiski, L. M. (2001) · Medical Physics · doi:10.1118/1.1381548 · Cited by 190 · cited 1×
“Twelve geometry features are considered in this paper, including compactness [11], normalized distance moments (NDM2, NDM3, NDM4) [31], Fourier features [31], normalized radial length (NRL)-based features (μNRL, σNRL, ENRL, ARNRL) [11], and relative gradient orientation (RGO)-based features (μRGO, σRGO, ERGO) [32].”
BackgroundToward breast cancer diagnosis based on automated segmentation of masses in mammograms
Rojas‐Domínguez, A., & Nandi, A. K. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.006 · Cited by 130
Destounis, S. V., DiNitto, P. A., Logan-Young, W. W., Bonaccio, E., Zuley, M. L., & Willison, K. M. (2004) · Radiology · doi:10.1148/radiol.2322030034 · Cited by 124 · cited 1×
“As reported in [5], about 10%–25% of abnormal cases shown in mammography have been wrongly ignored by radiologists.”
BackgroundA comparison of wavelet and curvelet for breast cancer diagnosis in digital mammogram
Eltoukhy, M. M., Faye, I., & Belhouari, S. B. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.02.002 · Cited by 117 · cited 1×
“[15] compared the wavelet and curvelet transforms for breast cancer diagnosis.”
BackgroundCAD systems for mammography: a real opportunity? A review of the literature
Bazzocchi, M., Mazzarella, F., Frate, C. D., Girometti, F., & Zuiani, C. (2007) · La radiologia medica · doi:10.1007/s11547-007-0145-5 · Cited by 37 · cited 1×
“One way to reduce the false negative rate is to use double reading, which can improve the detection rate by 5%–15% [6].”
Background
Cited by
A comprehensive survey on support vector machine classification: Applications, challenges and trends
Cervantes, J., Garcia-Lamont, F., Rodríguez-Mazahua, L., & Lopez, A. (2020) · Neurocomputing · doi:10.1016/j.neucom.2019.10.118 · Cited by 2,381
Arevalo, J., González, F. A., Ramos-Pollán, R., Oliveira, J. L., & Guevara Lopez, M. A. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.014 · Cited by 476
Deep and machine learning techniques for medical imaging-based breast cancer: A comprehensive review
Houssein, E. H., Emam, M. M., Ali, A. A., & Suganthan, P. N. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.114161 · Cited by 404
Benign and malignant classification of mammogram images based on deep learning
Li, H., Zhuang, S., Li, D.-A., Zhao, J., & Ma, Y. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.017 · Cited by 200
An effective genetic algorithm-based feature selection method for intrusion detection systems
Halim, Z., Yousaf, M. N., Waqas, M., Sulaiman, M., Abbas, G., Hussain, M., Ahmad, I., & Hanif, M. (2021) · Computers & Security · doi:10.1016/j.cose.2021.102448 · Cited by 185
Metadata
- Authors
- Liu, X., & Tang, J.
- Venue
- IEEE Systems Journal
- Published
- 2014-09
- Volume
- 8
- Issue
- 3
- Pages
- 910-920
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- OpenAlex
- W2035009069
- Cited by
- 183
- References
- 33
- FWCI
- 14.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.