Mobile monitoring with wearable photoplethysmographic biosensors
Abstract
We address both technical and clinical issues of wearable biosensors (WBS). First, design concepts of a WBS are presented, with emphasis on the ring sensor developed by the author's group at MIT. The ring sensor is an ambulatory, telemetric, continuous health-monitoring device. This WBS combines miniaturized data acquisition features with advanced photoplethysmographic (PPG) techniques to acquire data related to the patient's cardiovascular state using a method that is far superior to existing fingertip PPG sensors. In particular, the ring sensor is capable of reliably monitoring a patient's heart rate, oxygen saturation, and heart rate variability. Technical issues, including motion artifact, interference with blood circulation, and battery power issues, are addressed, and effective engineering solutions to alleviate these problems are presented. Second, based on the ring sensor technology the clinical potentials of WBS monitoring are addressed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, Asada et al. [22] presented a ring sensor design for measuring blood oxygen saturation (SpO2) and heart rate.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Worn on the base of the finger (like a ring), it integrated techniques for motion artifact reduction, which were designed to improve measurement accuracy.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Applications of the ring sensor ranged from the diagnosis of hypertension to the management of congestive heart failure.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“The ring sensor was completely self-contained.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
Citations
Cites
Hansson, L., Zanchetti, A., Carruthers, S. G., Dahlöf, B., Elmfeldt, D., Julius, S., Ménard, J., Rahn, K. H., Wedel, H., & Westerling, S. (1998) · The Lancet · doi:10.1016/s0140-6736(98)04311-6 · Cited by 5,728
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Hu, F. B., Sigal, R. J., Rich-Edwards, J. W., Colditz, G. A., Solomon, C. G., Willett, W. C., Speizer, F. E., & Manson, J. E. (1999) · JAMA · doi:10.1001/jama.282.15.1433 · Cited by 914
Economic impact of heart failure in the United States: time for a different approach.
O'Connell, J. B., & Bristow, M. R. (1994) · PubMed · Cited by 659
Prognostic Value of Ambulatory Blood Pressure
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 616
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Massie, B. M., & Shah, N. B. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70173-x · Cited by 547
Treatment adherence in chronic disease
Dunbar‐Jacob, J. M., & Mortimer-Stephens, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00457-7 · Cited by 440
Precipitating factors leading to decompensation of heart failure. Traits among urban blacks
Ghali, J. K. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.148.9.2013 · Cited by 414
Research works printed but not linked: 6
- Lictenthal, 1996, Evaluation of signal extraction technology (SET) in preventing false alarms when using pulse oximetry in the recovery room, Anesthesiology, 86, S278
- Guyton, 1996, Textbook of Medical Physiology, 187
- Shaltis, 2001, Artifact resistant, power efficient, high speed modulation design for photo plethysmographic ring sensors, Ann. Biomed. Eng., 29, S
- Kahveci, 2000, A rare complication due to pulse oximetry in intensive care unit, Ann. Med. Sci., 9, 36
- 1999, American Heart Association, Heart and Stroke Statistical Update
- 10.5694/j.1326-5377.2002.tb04590.x · DOI
Cited by
Sorted by citations
Items 401–468 of 468
Wearable Pulse Oximetry in Construction Environments
Forsyth, J. B. (2010) · VTechWorks (Virginia Tech) · Cited by 1
Essalat, M., Mashhadi, M. B., & Marvasti, F. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2010.00769 · Cited by 1
Colombo, D. (2020) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · doi:10.6035/14109.2020.762821 · Cited by 1
MOBILE SYSTEMS DESIGN AND EVALUATION
Wei, J. C., & Dong, S. (2021) · Wiley eBooks · doi:10.1002/9781119636113.ch40 · Cited by 1
Yeow, J. T. W. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs0155 · Cited by 1
León, N. E. L. (2013) · doi:10.7764/tesisuc/ing/1858 · Cited by 1
Unveiling frustration : underlying mechanisms and individual differences
Yazdi, H. (2025) · doi:10.69622/28632836 · Cited by 1
Self-Mixing Interferometric Sensor Displacement Reference for PPG Motion Artifact Handling
Wijshoff, R. R., Aarts, R. M., Veen, J., van der Lee, A., & Presură, C. N. (2010) · TU/e Research Portal
Identifying Pairs in Simulated Bio-Medical Time-SeriesPreprint
Kartoun, U. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1306.0541
Schwarz, L., Paim, F. C. A., Sovierzoski, M. A., Neto, J. M., & Marques, J. L. B. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_199
The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light
Chang, K. Y., Ko, H., Lee, J. J., & Yoon, Y. R. (2014) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2014.35.5.125
Reconfigurable sensor networks with a real time optimization method
Quevedo-Teruel, Ó., & Rajo‐Iglesias, E. (2012) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2012.6206628
Cheng, X., & Zhao, X. (2014) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2014.7002796
Clinical measurements analysis of multi-spectral photoplethysmograph biosensors
Asare, L., Kviesis-Kipge, E., & Spīgulis, J. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2052254
Representation of Vital Signs in Minimal Parameter Set
Zhao, J., Wang, L., Mei, Z., & Guo, Y. W. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5514798
Design of a high-linearity up-conversion mixer for wireless body area sensor network applications
Huang, I.-Y., & Huang, W. (2012) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2012.6411225
A chipless sensor tag-based RFID technology for cyber-oriented environmental sensing applications
Shrestha, S., Agarwal, M., Phoha, V. V., & Varahramyan, K. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.818293
Study of nanosensor systems for hypertension associated cerebrovascular and cardiovascular disorders
Ramasamy, M., & Varadan, V. K. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2190840
An Intelligent Data Filtering Scheme for Real Time Monitoring of Physiological Traits
Biswas, M. I., & Walker, B. (2011) · International Journal of Communications Network and System Sciences · doi:10.4236/ijcns.2011.42013
A Novel Method and Testbed for Sensor Management and Patient Diagnosis
Wu, W. H., Batalin, M. A., Kaiser, W. J., Sarrafzadeh, M., & Bui, A. A. T. (2007) · Joint Workshop on High Confidence Medical Devices, Software, and Systems and Medical Device Plug-and-Play Interoperability (HCMDSS-MDPnP) · doi:10.1109/hcmdss-mdpnp.2007.14
Experimental Equipment for Data Collection
Kouřil, J., & Hošek, J. (2009)
A Health Monitoring System Based on Pocket PC for Community Aging Residents
Jian-xin, Z., Gao, L., & Zhang, X. (2008) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2008.677
Multimodal biometric analysis for monitoring of wellness
Constantine, G. M., Chiarulli, D. M., & Grigoryan, V. (2004)
Huang, I., Huang, W., Luo, R.-W., Lan, J.-W., Hsieh, C.-H., & Lin, Y. (2015) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2015.7370281
An Acoustically-Analytic Approach to Behavioral Patterns for Monitoring Living Activities
Liu, K.-C., Yan, G.-L., Chiu, Y., Tsai, M.-S., & Chung, K. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-92841-6_266
Pham, T. D. (2015) · Lecture notes in electrical engineering · doi:10.1007/978-3-662-46578-3_27
Chapter 6.1 PERSONAL HEALTHCARE DEVICES
Leonhardt, S. K. (2006)
Optical non-invasive blood pressure : PPG waveform-based estimation and verification
정인철 (2011) · YUHSpace (Yonsei University Medical Library)
Andelfinger, V. P., & Til, H. (2016) · Springer eBooks · doi:10.1007/978-3-658-12239-3_12
Personalized home medical testing technology and equipment
Lai, L., Zhang, L., & Wu, X. (2009) · International Conference on Future BioMedical Information Engineering · doi:10.1109/fbie.2009.5405830
Analysis of the Dynamic Motion for Biosignal Measurement in Wearable system
Kim, Y. S., & Lee, J. (2006) · ICSC Congress on Computational Intelligence Methods and Applications (CIMA) · doi:10.1109/cima.2005.1662314
PatNet: Exploring social media and bio-sensors for a patient driven health care system
Mahmud, N., & Payne, D. (2014) · eChallenges Conference
A Secured Patients Monitoring System Using Sensor Nodes in Health Care Institutions
Khilar, P. M., Khatua, S. S., & Swain, R. R. (2018) · International Conference on Recent Innovations in Electrical, Electronics & Communication Engineering (ICRIEECE) · doi:10.1109/icrieece44171.2018.9008858
Sistema Vestible para la Detección Simultánea y No Invasiva del ECG y el Flujo Sanguíneo
Méndez-Lira, O. A. (2018) · Revista Mexicana de Ingeniería Biomédica · doi:10.17488/rmib.39.3.4
Chinawa, J., Chukwu, B. F., & Chinawa, A. (2019) · Journal of Medical Sciences · doi:10.4103/jmedsci.jmedsci_199_18
Data Mining Techniques for the Detection of the Risk in Cardiovascular Diseases
Dinakaran, K., Priya, V., & Valarmathie, P. (2019) · Wiley eBooks · doi:10.1002/9781119439004.ch14
Brewing Heterogeneous Devices for Monitoring Cerebrovascular Oxygenation
Geetha, G., Geethalakshmi, S. N., & Mathivadhani, D. (2016) · World Scientific News
Recent Trends in Wearable Device Technology for Health State Monitoring
Ruby, E. D. K., Janani, P., Mahalakshmi, V. J., Sathyasri, B., & Chinnaiyan, V. K. (2021) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-7998-6870-5.ch009
NFC Enabled Wearable Device Connected With Android Smart Phone For Virtual Assistant Applications
Sowmiya, R., & Abinaya, S. (2021) · Int. J. of Aquatic Science
Design and Implementation of Heart Beat Monitor System
Oyediji, F. T., Aluko, A. O., & Adetunmbi, A. O. (2021) · Journal of Engineering Research and Reports · doi:10.9734/jerr/2021/v21i417460
Akishin, A. D., Николаев, А. П., & Pisareva, A. V. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2096/1/012186
(2015) · CRC Press eBooks · doi:10.1201/b19358-2
Wearing sensors inside and outside of the human body for the early detection of diseases
Zheng, Y., Jiang, Y., Luo, N., Ding, X., Zhang, Y., & Poon, C. C. Y. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00003-6
Building Smart City Solutions with Focus on Health Care and GDPR
Enler, E., Péntek, I., & Adamkó, A. (2021) · Springer eBooks · doi:10.1007/978-3-030-69698-6_93
A study on the possibility of a new hemodynamic monitoring using a piezoelectric sensor
西本, 千., 佐藤, 求., 吉岡, 淳., & 芝本, 隆. (2022) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.92.519
Álvarez-Romero, C., Polo-Molina, A., Sánchez-Úbeda, E. F., Jiménez-Juan, C., Cuadri-Benitez, M. P., Rivas-González, J. A., Portela, J., Palacios, R., García, C. R.-M., Roque, A. M. S., et al. (2024) · JMIR Formative Research · doi:10.2196/52344
Son, C.-W., Koh, S.-T., & Jeon, H. (2025) · Micromachines · doi:10.3390/mi16040398
A Low-Power, Wide-DR PPG Readout IC with VCO-Based Quantizer Embedded in Photodiode Driver Circuits
Noh, H., Kim, W., Kim, Y., Koh, S.-T., & Jeon, H. (2025) · Electronics · doi:10.3390/electronics14193834
Estimation of Noise Threshold of Pulse Sensor Signal Using Wavelet Transform
Kour, G., & Sambyal, P. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-11491-4_17
Habla, A. F., Soleim, S. B., Due, A. S., Tinglef, T. H., Eskelund, K., Díaz-i-Calvete, J., Larsen, K. M., Kristensen, T. D., Ebdrup, B. H., Nordentoft, M., et al. (2026) · PLoS ONE · doi:10.1371/journal.pone.0333716
Essays on individual, team, and artificial creativity : an experimental approach
Maltese, A.-G. (2024) · theses.fr (ABES) · doi:10.70675/76ddb35bz013bz4190z8a06ze36e259983b5
Electrically Conductive Textiles for Health Applications by Carbon Nanotube Coatings on Cotton
Trovato, V., Rosa, R. P., D’Agostino, A., Teblum, E., Kostikov, Y., Re, V., Nessim, G. D., & Rosace, G. (2026) · Springer Proceedings in Materials · doi:10.1007/978-3-032-20865-1_1
Dehghandar, M., Maryam, N., & Yousefi, N. F. (2026) · Digital Chinese Medicine · doi:10.1016/j.dcmed.2026.05.008
Yan, R., Rangarajan, E., Xu, Z., Orini, M., Clough, R. E., Rhode, K., & Alastruey, J. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118132
Biswas, R., & Sarkar, S. (2026) · Journal of Biophotonics · doi:10.1002/jbio.70340
Ţiţoc, O.-A., & Tudose, D. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.113072
Implementasi Algoritma Moving Average untuk Penapisan Noise pada Output Sensor MAX30102
Sari, C., Putra, R. P., Syufrijal, S., Yuninda, N. H., & Lubis, P. (2026) · ELECTRA Electrical Engineering Articles · doi:10.25273/electra.v7i1.25730
From organic photodetectors to monolithic skin-conformal photoplethysmography systems
Kim, J.-H., Chae, S., Yokota, T., Sun, L., Jeong, J., Lee, S., Lee, J., Lee, J., Heo, J. H., Lee, S., et al. (2026) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2026.101313
A Study on H.264 Live Video Technology with Android System
Dong, J., Xin, J., & Zhuang, P. (2015) · Communications in computer and information science · doi:10.1007/978-3-662-47791-5_15
Kim, M.-H., & Kim, H.-J. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40852-6_3
Metadata
- Authors
- Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C.
- Affiliations
- Massachusetts Institute of Technology (US)
- Albion College (US)
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2003-05
- Volume
- 22
- Issue
- 3
- Pages
- 28-40
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2019882679
- Cited by
- 466
- References
- 67
- Citations by year
- 2026: 13 · 2025: 10 · 2024: 11 · 2023: 13 · 2022: 13 · 2021: 19 · 2020: 31 · 2019: 22 · 2018: 21 · 2017: 19 · 2016: 24 · 2015: 34 · 2014: 42 · 2013: 18 · 2012: 29
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable biosensors, photoplethysmography, telemetry monitoring, heart rate monitoring, oxygen saturation, heart rate variability, motion artifacts, battery power, cardiovascular monitoring
- MeSH terms
- Cardiovascular Diseases, Chronic Disease, Equipment Design, Fingers, Heart Failure, Heart Rate, Humans, Hypertension, Oxygen Consumption, Biosensing Techniques, Electrocardiography, Ambulatory, Photoplethysmography, Blood Pressure Monitoring, Ambulatory, Monitoring, Ambulatory, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review