The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Mobile monitoring with wearable photoplethysmographic biosensors
Abstract
We address both technical and clinical issues of wearable biosensors (WBS). First, design concepts of a WBS are presented, with emphasis on the ring sensor developed by the author's group at MIT. The ring sensor is an ambulatory, telemetric, continuous health-monitoring device. This WBS combines miniaturized data acquisition features with advanced photoplethysmographic (PPG) techniques to acquire data related to the patient's cardiovascular state using a method that is far superior to existing fingertip PPG sensors. In particular, the ring sensor is capable of reliably monitoring a patient's heart rate, oxygen saturation, and heart rate variability. Technical issues, including motion artifact, interference with blood circulation, and battery power issues, are addressed, and effective engineering solutions to alleviate these problems are presented. Second, based on the ring sensor technology the clinical potentials of WBS monitoring are addressed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, Asada et al. [22] presented a ring sensor design for measuring blood oxygen saturation (SpO2) and heart rate.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Worn on the base of the finger (like a ring), it integrated techniques for motion artifact reduction, which were designed to improve measurement accuracy.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Applications of the ring sensor ranged from the diagnosis of hypertension to the management of congestive heart failure.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“The ring sensor was completely self-contained.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
Citations
Cites
Hansson, L., Zanchetti, A., Carruthers, S. G., Dahlöf, B., Elmfeldt, D., Julius, S., Ménard, J., Rahn, K. H., Wedel, H., & Westerling, S. (1998) · The Lancet · doi:10.1016/s0140-6736(98)04311-6 · Cited by 5,728
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Hu, F. B., Sigal, R. J., Rich-Edwards, J. W., Colditz, G. A., Solomon, C. G., Willett, W. C., Speizer, F. E., & Manson, J. E. (1999) · JAMA · doi:10.1001/jama.282.15.1433 · Cited by 914
Economic impact of heart failure in the United States: time for a different approach.
O'Connell, J. B., & Bristow, M. R. (1994) · PubMed · Cited by 659
Prognostic Value of Ambulatory Blood Pressure
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 616
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Massie, B. M., & Shah, N. B. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70173-x · Cited by 547
Treatment adherence in chronic disease
Dunbar‐Jacob, J. M., & Mortimer-Stephens, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00457-7 · Cited by 440
Precipitating factors leading to decompensation of heart failure. Traits among urban blacks
Ghali, J. K. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.148.9.2013 · Cited by 414
Rich, M. W. (1997) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1997.tb02968.x · Cited by 381
Etiologic factors in pressure sores: an experimental model.
Daniel, R. K., Priest, D., & Wheatley, D. (1981) · PubMed · Cited by 374
Cardiorespiratory Events Recorded on Home Monitors
Ramanathan, R., Corwin, M. J., Hunt, C. E., Lister, G., Tinsley, L. R., Baird, T. M., Silvestri, J. M., Crowell, D. H., Hufford, D. R., Martin, R. J., et al. (2001) · JAMA · doi:10.1001/jama.285.17.2199 · Cited by 348
Medication Compliance in the Elderly
Stewart, R. B., & Caranasos, G. J. (1989) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30616-2 · Cited by 297
Mortality in Patients of the Glasgow Blood Pressure Clinic
Isles, C., Walker, L. M., Beevers, G., Brown, I., Cameron, H. L., Clarke, J. M., Hawthorne, V. M., Hole, D. J., Lever, A. F., Robertson, J. W. K., et al. (1986) · Journal of Hypertension · doi:10.1097/00004872-198604000-00003 · Cited by 261
Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography
Mendelson, Y., & Ochs, B. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7286 · Cited by 251
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Self-citationPhysiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Do Hospital Fall Prevention Programs Work? A Systematic Review
Oliver, D., Hopper, A., & Seed, P. T. (2000) · Journal of The American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb03883.x · Cited by 211
Photon migration in the presence of a single defect: a perturbation analysis
Feng, S. C., Zeng, F., & Chance, B. (1995) · Applied Optics · doi:10.1364/ao.34.003826 · Cited by 195
Epidemiology of SIDS and Explained Sudden Infant Deaths
Leach, C. E. A., Blair, P. S., Fleming, P., Smith, I. J., Platt, M. W., Berry, P. J., BCH, F., & Golding, J. (1999) · PEDIATRICS · doi:10.1542/peds.104.4.e43 · Cited by 180
Treatment-Induced Blood Pressure Reduction and the Risk of Myocardial Infarction
Alderman, M. H. (1989) · JAMA · doi:10.1001/jama.1989.03430070068032 · Cited by 173
Hint for squint: a computer reliant diagnostic aid for strabismus
Gieszl, L. R., Morris, J. V., & Guyton, D. L. (2005) · Symposium on Computer Applications in Medical Care (SCAMC) · doi:10.1109/scamc.1983.764787 · Cited by 157
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442797 · Cited by 129
Auditory Alarms during Anesthesia Monitoring
Kestin, I. G., Miller, B. R., & Lockhart, C. H. (1988) · Anesthesiology · doi:10.1097/00000542-198807000-00018 · Cited by 110
Ambulatory Blood Pressure Monitoring and Echocardiographic Left Ventricular Wall Thickness and Mass
Prisant, L. M., & Carr, A. A. (1990) · American Journal of Hypertension · doi:10.1093/ajh/3.2.81 · Cited by 109
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442798 · Cited by 104
Clayton, D. G., Webb, R. K., Ralston, A., DUTHIE, D., & Runciman, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb11492.x · Cited by 90
Wave-velocity in the proximal aorta
Nichols, W. W., & McDonald, D. A. (1972) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474213 · Cited by 88
Ambulatory blood pressure monitoring
McGrath, B. P. (2002) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2002.tb04590.x · Cited by 85
Optimal probe geometry for near-infrared spectroscopy of biological tissue
Kumar, G., & Schmitt, J. M. (1997) · Applied Optics · doi:10.1364/ao.36.002286 · Cited by 83
Mejia, A. D., Egan, B. M., Schork, N. J., & Zweifler, A. J. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-4-270 · Cited by 81
Verdecchia, P., Clement, D. L., Fagard, R. H., Palatini, P., & Parati, G. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900460-00004 · Cited by 77
Transmission characteristics of axial waves in blood vessels
Anliker, M., Moritz, W. E., & Ogden, E. (1968) · Journal of Biomechanics · doi:10.1016/0021-9290(68)90019-5 · Cited by 76
Task Force III: Target-organ damage, morbidity and mortality
Verdecchia, P., Clement, D., Fagard, R., Palatini, P., & Parati, G. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199912000-00004 · Cited by 75
Toe temperature versus transcutaneous oxygen tension monitoring during acute circulatory failure
Vincent, J., Moraine, J.-J., & van der Linden, P. (1988) · Intensive Care Medicine · doi:10.1007/bf00254125 · Cited by 59
Feng, W., Haishu, D., Fenghua, T., Zhao, J., Xia, Q. L., & Xianwu, T. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/1/323 · Cited by 53
AN EPIDEMIOLOGICAL STUDY OF FALLS ON INTEGRATED GENERAL MEDICAL WARDS
Vassallo, M., Azeem, T. A. E., Pirwani, M., Sharma, J., & Allen, S. (2000) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2000.tb10951.x · Cited by 47
Home monitoring of infants considered at risk for the sudden infant death syndrome
Kahn, A., & Blum, D. (1982) · European Journal of Pediatrics · doi:10.1007/bf00441489 · Cited by 42
Measurement of toe temperature for assessing the severity of acute circulatory failure.
Henning, R. J., Wiener, F., Valdes, S., & Weil, M. H. (1979) · PubMed · Cited by 41
Treatment-induced blood pressure reduction and the risk of myocardial infarction
Alderman, M. H. (1989) · JAMA · doi:10.1001/jama.262.7.920 · Cited by 38
Near Miss Sudden Infant Death Syndrome Episodes? A Clinical and Electrocardiographic Correlation
Krongrad, E., & O’Neill, L. D. (1986) · PEDIATRICS · doi:10.1542/peds.77.6.811 · Cited by 37
Froom, P., Bar-David, M., Ribak, J., Dyk, D. V., Kallner, B., & Benbassat, J. (1983) · Circulation · doi:10.1161/01.cir.68.3.467 · Cited by 34
Second Derivative of Photoplethysmogram in Children and Young People
IKETANI, Y., Iketani, T., Takazawa, K., & Murata, M. (2000) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.64.110 · Cited by 29
Home Monitoring for the Sudden Infant Death Syndrome
Hodgman, J. E., & HOPPENBROUWERS, T. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb37246.x · Cited by 28
Forearm arterial compliance: a new measure of arterial compliance?
Dh, F. (1984) · Cardiovascular Research · doi:10.1093/cvr/18.11.651 · Cited by 28
Shimazu, H., KAWARADA, A., Ito, H., & Yamakoshi, K.-I. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441465 · Cited by 24
How Far Should Blood Pressure Be Lowered?: What Is the Role of the J-Curve?
Hansson, L. (1990) · American Journal of Hypertension · doi:10.1093/ajh/3.9.726 · Cited by 24
SIDS, ALTE, Apnea, and the Use of Home Monitors
Farrell, P. A., Weiner, G. M., & Lemons, J. A. (2002) · Pediatrics in Review · doi:10.1542/pir.23-1-3 · Cited by 22
Rhee, S., Yang, B., & Asada, H. H. (2002) · doi:10.1109/iembs.2000.901443 · Cited by 20
Self-citationHow prevalence of hypertension varies as diagnostic criteria change
Alderman, M. H., & Yano, K. (1976) · The American Journal of the Medical Sciences · doi:10.1097/00000441-197605000-00010 · Cited by 17
Ischemic and pressure-induced hyperemia: A comparison
Rendell, M., & Wells, J. M. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90243-x · Cited by 17
Why ambulatory blood pressure monitoring?
Punzi, H. A. (1998) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/55.suppl_3.s12 · Cited by 15
McGrath, B. P., Langton, D., Matthews, P. G., SYME, S. L., Treloar, K. L., & McNeil, J. J. (1989) · Journal of Hypertension · doi:10.1097/00004872-198908000-00008 · Cited by 14
Severe Injury and Death Associated With Home Infant Cardiorespiratory Monitors
Katcher, M. L., Shapiro, M. M., & Guist, C. (1986) · PEDIATRICS · doi:10.1542/peds.78.5.775 · Cited by 12
Accuracy and utility of pulse oximetry in the surgical intensive care unit.
Bentt, L., Santora, T. A., Bj, L., LoBue, M., & Shabot, M. M. (1990) · PubMed · Cited by 12
Quantitative evaluation of photoplethysmographic artifact reduction for pulse oximetry
Hayes, M. J., & Smith, P. R. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.336924 · Cited by 11
Home Monitoring for the Sudden Infant Death Syndrome
Kelly, D. H. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb37245.x · Cited by 10
ACCURACY AND UTILITY OF PULSE OXIMETRY IN A SURGICAL INTENSIVE CARE UNIT
Bentt, L., Sanlora, T. A., Leyerle, B. J., LoBue, M., & Shabot, M. M. (1990) · Critical Care Medicine · doi:10.1097/00003246-199012001-00031 · Cited by 8
Accuracy in clinical arrhythmia detection of a real-time Holter system (Oxford Medilog 4500)
Lanza, G. A., Lucente, M., Rebuzzi, A. G., Cortellessa, M. C., Tamburi, S., Mancuso, P., Neri, R., & Manzoli, U. C. (1990) · Journal of Electrocardiology · doi:10.1016/0022-0736(90)90119-m · Cited by 8
Adaptive pre-processing of photoplethysmographic blood volume pulse measurements
Vicente, L., Barreto, A. B., & Taberner, A. M. (2002) · Proceedings of the ... Southern Biomedical Engineering Conference · doi:10.1109/sbec.1996.493126 · Cited by 6
Blood Pressure as a Surrogate End Point for Hypertension
Carter, B. L. (2002) · Annals of Pharmacotherapy · doi:10.1345/aph.1a069 · Cited by 6
Holter triage ambulatory ECG analysis
Cooper, D. H., Kennedy, H. L., Lyyski, D. S., & Sprague, M. K. (1996) · Journal of Electrocardiology · doi:10.1016/s0022-0736(96)80109-9 · Cited by 6
Design of a artifact-free wearable plethysmographic sensor
Rhee, S., Yang, B.-H., & Asada, H. H. (2003) · doi:10.1109/iembs.1999.803941 · Cited by 4
Self-citationCost effectiveness analyses have been carried out in Sweden: Table 1
Lindholm, L. H., & Werkö, L. (1996) · BMJ · doi:10.1136/bmj.313.7066.1203b · Cited by 3
Flagged first, then by citations
Research works printed but not linked: 6
- Lictenthal, 1996, Evaluation of signal extraction technology (SET) in preventing false alarms when using pulse oximetry in the recovery room, Anesthesiology, 86, S278
- Guyton, 1996, Textbook of Medical Physiology, 187
- Shaltis, 2001, Artifact resistant, power efficient, high speed modulation design for photo plethysmographic ring sensors, Ann. Biomed. Eng., 29, S
- Kahveci, 2000, A rare complication due to pulse oximetry in intensive care unit, Ann. Med. Sci., 9, 36
- 1999, American Heart Association, Heart and Stroke Statistical Update
- 10.5694/j.1326-5377.2002.tb04590.x · DOI
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Heron, K. E., & Smyth, J. M. (2010) · British Journal of Health Psychology · doi:10.1348/135910709x466063 · Cited by 1,438
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Metadata
- Authors
- Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C.
- Affiliations
- Massachusetts Institute of Technology (US)
- Albion College (US)
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2003-05
- Volume
- 22
- Issue
- 3
- Pages
- 28-40
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2019882679
- Cited by
- 466
- References
- 67
- Citations by year
- 2026: 13 · 2025: 10 · 2024: 11 · 2023: 13 · 2022: 13 · 2021: 19 · 2020: 31 · 2019: 22 · 2018: 21 · 2017: 19 · 2016: 24 · 2015: 34 · 2014: 42 · 2013: 18 · 2012: 29
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable biosensors, photoplethysmography, telemetry monitoring, heart rate monitoring, oxygen saturation, heart rate variability, motion artifacts, battery power, cardiovascular monitoring
- MeSH terms
- Cardiovascular Diseases, Chronic Disease, Equipment Design, Fingers, Heart Failure, Heart Rate, Humans, Hypertension, Oxygen Consumption, Biosensing Techniques, Electrocardiography, Ambulatory, Photoplethysmography, Blood Pressure Monitoring, Ambulatory, Monitoring, Ambulatory, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review