The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Mobile monitoring with wearable photoplethysmographic biosensors
Abstract
We address both technical and clinical issues of wearable biosensors (WBS). First, design concepts of a WBS are presented, with emphasis on the ring sensor developed by the author's group at MIT. The ring sensor is an ambulatory, telemetric, continuous health-monitoring device. This WBS combines miniaturized data acquisition features with advanced photoplethysmographic (PPG) techniques to acquire data related to the patient's cardiovascular state using a method that is far superior to existing fingertip PPG sensors. In particular, the ring sensor is capable of reliably monitoring a patient's heart rate, oxygen saturation, and heart rate variability. Technical issues, including motion artifact, interference with blood circulation, and battery power issues, are addressed, and effective engineering solutions to alleviate these problems are presented. Second, based on the ring sensor technology the clinical potentials of WBS monitoring are addressed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, Asada et al. [22] presented a ring sensor design for measuring blood oxygen saturation (SpO2) and heart rate.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Worn on the base of the finger (like a ring), it integrated techniques for motion artifact reduction, which were designed to improve measurement accuracy.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“Applications of the ring sensor ranged from the diagnosis of hypertension to the management of congestive heart failure.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
In the citing paper
“The ring sensor was completely self-contained.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [22]
Citations
Cites
Hansson, L., Zanchetti, A., Carruthers, S. G., Dahlöf, B., Elmfeldt, D., Julius, S., Ménard, J., Rahn, K. H., Wedel, H., & Westerling, S. (1998) · The Lancet · doi:10.1016/s0140-6736(98)04311-6 · Cited by 5,728
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Hu, F. B., Sigal, R. J., Rich-Edwards, J. W., Colditz, G. A., Solomon, C. G., Willett, W. C., Speizer, F. E., & Manson, J. E. (1999) · JAMA · doi:10.1001/jama.282.15.1433 · Cited by 914
Economic impact of heart failure in the United States: time for a different approach.
O'Connell, J. B., & Bristow, M. R. (1994) · PubMed · Cited by 659
Prognostic Value of Ambulatory Blood Pressure
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 616
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Massie, B. M., & Shah, N. B. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70173-x · Cited by 547
Treatment adherence in chronic disease
Dunbar‐Jacob, J. M., & Mortimer-Stephens, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00457-7 · Cited by 440
Precipitating factors leading to decompensation of heart failure. Traits among urban blacks
Ghali, J. K. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.148.9.2013 · Cited by 414
Research works printed but not linked: 6
- Lictenthal, 1996, Evaluation of signal extraction technology (SET) in preventing false alarms when using pulse oximetry in the recovery room, Anesthesiology, 86, S278
- Guyton, 1996, Textbook of Medical Physiology, 187
- Shaltis, 2001, Artifact resistant, power efficient, high speed modulation design for photo plethysmographic ring sensors, Ann. Biomed. Eng., 29, S
- Kahveci, 2000, A rare complication due to pulse oximetry in intensive care unit, Ann. Med. Sci., 9, 36
- 1999, American Heart Association, Heart and Stroke Statistical Update
- 10.5694/j.1326-5377.2002.tb04590.x · DOI
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Heron, K. E., & Smyth, J. M. (2010) · British Journal of Health Psychology · doi:10.1348/135910709x466063 · Cited by 1,438
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
A review of smart homes—Present state and future challenges
Chan, M., Estève, D., Escriba, C., & Campo, E. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.001 · Cited by 1,007
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 828
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G., Zhao, N., & Zhang, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 725
Pervasive Healthcare and Wireless Health Monitoring
Varshney, U. (2007) · Mobile Networks and Applications · doi:10.1007/s11036-007-0017-1 · Cited by 680
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
Classification of basic daily movements using a triaxial accelerometer
Mathie, M. J., Celler, B. G., Lovell, N. H., & Coster, A. C. F. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347551 · Cited by 451
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
A Cloud Computing Solution for Patient's Data Collection in Health Care Institutions
Rolim, C. O., Koch, F. L., Westphall, C. B., Werner, J., Fracalossi, A., & Salvador, G. S. (2010) · International Conference on eHealth, Telemedicine, and Social Medicine · doi:10.1109/etelemed.2010.19 · Cited by 413
The adoption of mobile healthcare by hospital's professionals: An integrative perspective
Wu, I., Li, J.-Y., & Fu, C.-Y. (2011) · Decision Support Systems · doi:10.1016/j.dss.2011.03.003 · Cited by 429
Flexible Molybdenum Disulfide (MoS 2 ) Atomic Layers for Wearable Electronics and Optoelectronics
Singh, E. J., Singh, P., Kim, K. S., Yeom, G. Y., & Nalwa, H. S. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b19859 · Cited by 406
Flexible Electronics: Status, Challenges and Opportunities
Corzo, D., Tostado‐Blazquez, G., & Baran, D. (2020) · Frontiers in Electronics · doi:10.3389/felec.2020.594003 · Cited by 414
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2019) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2019.100523 · Cited by 391
Stress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., Lords, A. O., Raŝković, D., Cox, P. G., Adhami, R. R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 372
Wearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
Flexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galán, T., Gupta, S., Marques, M. M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 301
A Review of Approaches to Mobility Telemonitoring of the Elderly in Their Living Environment
Scanaill, C. N., Carew, S., Barralon, P., Noury, N., Lyons, D., & Lyons, G. M. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9068-2 · Cited by 265
Wireless Sensor Networks and Chemo-/Biosensing
Diamond, D., Coyle, S. M., Scarmagnani, S., & Hayes, J. (2008) · Chemical Reviews · doi:10.1021/cr0681187 · Cited by 265
Wireless Health Care Service System for Elderly With Dementia
Lin, C.-C., Chiu, M., Hsiao, C.-C., Lee, R.-G., & Tsai, Y.-S. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.874196 · Cited by 260
Webb, R. C., Ma, Y., Krishnan, S. R., Li, Y., Yoon, S. P., Guo, X., Feng, X., Shi, Y., Seidel, M., Cho, N. H., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500701 · Cited by 247
Hiremath, S., Yang, G., & Mankodiya, K. (2014) · Wireless Mobile Communication and Healthcare · doi:10.4108/icst.mobihealth.2014.257440 · Cited by 244
A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications
Wu, T., Wu, F., Qiu, C., Redouté, J., & Yuce, M. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977164 · Cited by 230
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Yousefi, R., Nourani, M., Ostadabbas, S., & Panahi, I. M. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2264358 · Cited by 229
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
Systems biology primer: the basic methods and approaches
Tavassoly, I., Goldfarb, J., & Iyengar, R. (2018) · Essays in Biochemistry · doi:10.1042/ebc20180003 · Cited by 228
Mobile health: Four emerging themes of research
Varshney, U. (2014) · Decision Support Systems · doi:10.1016/j.dss.2014.06.001 · Cited by 216
Wearable medical devices for tele-home healthcare
Hung, K., Zhang, Y. T., & Tai, B. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404503 · Cited by 211
The advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209
Mihailidis, A., Carmichael, B., & Boger, J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.834386 · Cited by 208
Zeagler, C. (2017) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3123021.3123042 · Cited by 215
Colombo, D., Fernández-Álvarez, J., Patané, A., Semonella, M., Kwiatkowska, M., García-Palacios, A., Cipresso, P., Riva, G., & Botella, C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8040465 · Cited by 194
Singh, R. R., Conjeti, S., & Banerjee, R. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.06.014 · Cited by 199
Skin-electrode iontronic interface for mechanosensing
Zhu, P., Du, H., Hou, X., Lü, P., Wang, L., Huang, J., Bai, N., Wu, Z., Fang, N. X., & Guo, C. F. (2021) · Nature Communications · doi:10.1038/s41467-021-24946-4 · Cited by 194
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189
Hiemath, S., Yang, G., & Mankodiya, K. (2014) · Journal of Media Literacy Education · doi:10.1109/mobihealth.2014.7015971 · Cited by 174
Poongodi, T., Krishnamurthi, R., Indrakumari, R., Suresh, P., & Balusamy, B. (2019) · Intelligent systems reference library · doi:10.1007/978-3-030-23983-1_10 · Cited by 161
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Lee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 155
Wireless Body Area Networks for Healthcare: A Survey
Crosby, G. V. (2012) · International Journal of Ad hoc Sensor & Ubiquitous Computing · doi:10.5121/ijasuc.2012.3301 · Cited by 155
A mobile data collection platform for mental health research
Gaggioli, A., Pioggia, G., Tartarisco, G., Baldus, G., Corda, D., Cipresso, P., & Riva, G. (2011) · Personal and Ubiquitous Computing · doi:10.1007/s00779-011-0465-2 · Cited by 165
Recent developments and trends in biomedical sensors
Engin, M., Demirel, A., Engın, E. Z., & Fedakar, M. (2004) · Measurement · doi:10.1016/j.measurement.2004.11.002 · Cited by 140
MEDIC: Medical embedded device for individualized care
Wu, W. H., Bui, A. A. T., Batalin, M. A., Au, L. K., Binney, J., & Kaiser, W. J. (2008) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2007.11.006 · Cited by 143
Peng, F., Zhang, Z., Gou, X., Liu, H., & Wang, W. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-50 · Cited by 136
Body Sensor Networks: In the Era of Big Data and Beyond
Poon, C. C. Y., Lo, B. P. L., Yuce, M. R., Alomainy, A., & Hao, Y. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2427254 · Cited by 135
Ali, S. M., Cheab, S., Imran, M. A., Soeung, S., Abbasi, Q., & Abidin, Z. (2020) · Micromachines · doi:10.3390/mi11100888 · Cited by 127
Kroll, R. R., Boyd, J. G., & Maslove, D. M. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.6025 · Cited by 123
Sun, B., & Zhang, Z. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473697 · Cited by 115
Khan, A., Siddiqi, M., & Lee, S. W. (2013) · Sensors · doi:10.3390/s131013099 · Cited by 114
Active noise cancellation using MEMS accelerometers for motion-tolerant wearable bio-sensors
Asada, H. H., Jiang, H.-H., & Gibbs, P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403631 · Cited by 113
Self-citationHeart rate monitoring via remote photoplethysmography with motion artifacts reduction
Cennini, G., Arguel, J., Akşit, K., & van Leest, A. J. (2010) · Optics Express · doi:10.1364/oe.18.004867 · Cited by 111
The Agenda of Wearable Healthcare
Tröster, G. (2005) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638446 · Cited by 109
Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor
Park, J.-H., Jang, D.-G., Park, J., & Youm, S. (2015) · Sensors · doi:10.3390/s150923402 · Cited by 105
An intelligent mobile based decision support system for retinal disease diagnosis
Bourouis, A., Feham, M., Hossain, M. A., & Zhang, L. (2014) · Decision Support Systems · doi:10.1016/j.dss.2014.01.005 · Cited by 103
Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography
Han, H., Kim, M.-J., & Kim, J. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352596 · Cited by 101
Khan, A., Lee, Y.-K., Lee, S., & Kim, T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0701-3 · Cited by 91
Telemetric monitoring in the behavior sciences
Goodwin, M. S., Velicer, W. F., & Intille, S. S. (2008) · Behavior Research Methods · doi:10.3758/brm.40.1.328 · Cited by 91
Paoletti, M., & Marchesi, C. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.01.005 · Cited by 89
Kazanskiy, N. L., Butt, M. A., & Khonina, S. N. (2022) · Nanomaterials · doi:10.3390/nano12030334 · Cited by 92
Heart failure patients monitoring using IoT-based remote monitoring system
Umer, M., Aljrees, T., Karamti, H., Ishaq, A., Alsubai, S., Omar, M., Bashir, A. K., & Ashraf, I. (2023) · Scientific Reports · doi:10.1038/s41598-023-46322-6 · Cited by 87
Smyth, J. M., & Heron, K. E. (2016) · Wireless Health · doi:10.1109/wh.2016.7764561 · Cited by 94
Estimation of blood glucose by non-invasive method using photoplethysmography
Habbu, S. K., Dale, M. P., & Ghongade, R. (2019) · Sadhana · doi:10.1007/s12046-019-1118-9 · Cited by 85
Acceptance of pervasive healthcare systems: A comparison of different implementation concepts
Ziefle, M., & Röcker, C. (2010) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth2010.8915 · Cited by 85
Fluorescence analyzer based on smartphone camera and wireless for detection of Ochratoxin A
Bueno, D., Muñoz, R., & Marty, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.140 · Cited by 84
Low-Power Analog Integrated Circuits for Wireless ECG Acquisition Systems
Tsai, T., Hong, J.-H., Wang, L.-H., & Lee, S.-Y. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188412 · Cited by 82
Advances in wearable technology and its medical applications
Bonato, P. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5628037 · Cited by 81
Ubiquitous wireless telemedicine
Rashvand, H. F., Traver, V., Sanchez, E. M., & Iliescu, D. D. (2008) · IET Communications · doi:10.1049/iet-com:20070361 · Cited by 80
Lifeguard - a personal physiological monitor for extreme environments
Montgomery, K. N., Mundt, C. W., Thonier, G., Tellier, A., Udoh, U. E., Barker, V., Ricks, R., Giovangrandi, L., Davies, P., Cagle, Y. D., et al. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403640 · Cited by 78
Sun, X., Yang, P., Li, Y., Gao, Z., & Zhang, Y. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211698 · Cited by 75
Li, K., & Warren, S. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2167717 · Cited by 73
Technological Innovations Enabling Automatic, Context-Sensitive Ecological Momentary Assessment
Intille, S. S. (2007) · The Science of Real-Time Data Capture · doi:10.1093/oso/9780195178715.003.0016 · Cited by 72
A Low-Power RFID Integrated Circuits for Intelligent Healthcare Systems
Lee, S.-Y., Wang, L.-H., & Fang, Q. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2053942 · Cited by 71
What Planner for Ambient Intelligence Applications?
Francesco Amigoni, A., Gatti, N., Pinciroli, C., & Roveri, M. (2004) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2004.838465 · Cited by 71
Adaptive Noise Cancellation Using Accelerometers for the PPG Signal from Forehead
Kim, S. H., Ryoo, D. W., & Bae, C. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352852 · Cited by 70
Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study
for the WEARable Information Technology for hospital INpatients (WEARIT-IN) study group, Kroll, R. R., McKenzie, E. D., Boyd, J. G., Sheth, P., Howes, D., Wood, M., & Maslove, D. M. (2017) · Journal of Intensive Care · doi:10.1186/s40560-017-0261-9 · Cited by 69
IoT Based Heart Activity Monitoring Using Inductive Sensors
Brezulianu, A., Geman, O., Zbancioc, M. D., Hăgan, M., Aghion, C., Hemanth, D. J., & Sơn, L. H. (2019) · Sensors · doi:10.3390/s19153284 · Cited by 69
In-Ear Vital Signs Monitoring Using a Novel Microoptic Reflective Sensor
Vogel, S., Hülsbusch, M., Hennig, T., Blažek, V., & Leonhardt, S. K. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033268 · Cited by 68
Success factors in developing iHeart as a patient-centric healthcare system: A multi-group analysis
Keikhosrokiani, P., Mustaffa, N., & Zakaria, N. (2017) · Telematics and Informatics · doi:10.1016/j.tele.2017.11.006 · Cited by 66
Hu, Q., Tang, X., & Tang, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3043416 · Cited by 65
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Chua, C. P., & Heneghan, C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259612 · Cited by 65
Reduction of Periodic Motion Artifacts in Photoplethysmography
Wijshoff, R. W. C. G. R., Mischi, M., & Aarts, R. M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2553060 · Cited by 66
M-Health: Skin Disease Analysis System Using Smartphone's Camera
Bourouis, A., Zerdazi, A., Feham, M., & Bouchachia, A. (2013) · Procedia Computer Science · doi:10.1016/j.procs.2013.06.157 · Cited by 62
Gibbs, P., & Asada, H. H. (2005) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2005.1470193 · Cited by 62
Self-citationSherrill, D. M., Moy, M. L., Reilly, J. J., & Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-16 · Cited by 63
Leonhardt, S. K. (2006) · Philips Research · doi:10.1007/1-4020-4198-5_17 · Cited by 60
Data mining of motor patterns recorded with wearable technology
Bonato, P., Mork, P. J., Sherrill, D. M., & Westgaard, R. H. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213634 · Cited by 59
Powell, L., Parker, J., James, M. M., & Mawson, S. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5891 · Cited by 58
Physical Workload Tracking Using Human Activity Recognition with Wearable Devices
Manjarrés, J., Narváez, P., Gasser, K., Percybrooks, W., & Pardo, M. (2019) · Sensors · doi:10.3390/s20010039 · Cited by 58
Cao, Y., Chen, H., Li, F., & Wang, Y. (2021) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3447993.3483241 · Cited by 57
Abdelbasset, W. K., Savina, S. V., Mavaluru, D., SHICHIYAKH, R. A., Bokov, D. O., & Mustafa, Y. F. (2022) · Talanta · doi:10.1016/j.talanta.2022.123769 · Cited by 54
Local Dynamic Stability Assessment of Motion Impaired Elderly Using Electronic Textile Pants
Liu, J., Lockhart, T. E., Jones, M., & Martin, T. L. (2008) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2008.923821 · Cited by 53
Bidirectional Recurrent Auto-Encoder for Photoplethysmogram Denoising
Lee, J., Sun, S., Yang, S.-M., Sohn, J., Park, J., Lee, S., & Kim, H. C. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2885139 · Cited by 54
Metadata
- Authors
- Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C.
- Affiliations
- Massachusetts Institute of Technology (US)
- Albion College (US)
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2003-05
- Volume
- 22
- Issue
- 3
- Pages
- 28-40
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2019882679
- Cited by
- 466
- References
- 67
- Citations by year
- 2026: 13 · 2025: 10 · 2024: 11 · 2023: 13 · 2022: 13 · 2021: 19 · 2020: 31 · 2019: 22 · 2018: 21 · 2017: 19 · 2016: 24 · 2015: 34 · 2014: 42 · 2013: 18 · 2012: 29
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable biosensors, photoplethysmography, telemetry monitoring, heart rate monitoring, oxygen saturation, heart rate variability, motion artifacts, battery power, cardiovascular monitoring
- MeSH terms
- Cardiovascular Diseases, Chronic Disease, Equipment Design, Fingers, Heart Failure, Heart Rate, Humans, Hypertension, Oxygen Consumption, Biosensing Techniques, Electrocardiography, Ambulatory, Photoplethysmography, Blood Pressure Monitoring, Ambulatory, Monitoring, Ambulatory, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review