The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Dynamic magnetic resonance imaging of tumor perfusion
Abstract
This work presents approaches and biomedical challenges of dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). DCE-MRI using small molecular weight gadolinium chelates enables noninvasive imaging characterization of tissue vascularity. Depending on the technique used, data reflecting tissue perfusion (blood flow, blood volume, mean transit time), microvessel permeability surface area product, and extracellular leakage space can be obtained. Insights into these physiological processes can be obtained from inspection of kinetic enhancement curves or by the application of complex compartmental modeling techniques. Potential clinical applications include screening for malignant disease, lesion characterization, monitoring lesion response to treatment, and assessment of residual disease. Newer applications include prognostication, pharmacodynamic assessments of antivascular anticancer drugs, and predicting efficacy of treatment. For dynamic MRI to enter into widespread clinical practice, it will be necessary to develop standardized approaches to measurement and robust analysis approaches. These include the need for commercial equipment manufacturers to provide robust methods for rapidly measuring time-varying change in T1 relaxation rates, incorporation of arterial input function into kinetic modeling processes, robust analysis software that allows input from a variety of MRI devices, and validated statistical tools for the evaluation of heterogeneity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Dvorak, H. F., Nagy, J. A., Feng, D., Brown, L. F., & Dvorak, A. M. (1999) · Current Topics in Microbiology and Immunology · doi:10.1007/978-3-642-59953-8_6 · Cited by 743
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Wenz, F., Rempp, K., Brix, G., Knopp, M. V., Gückel, F., Heß, T., & van Kaick, G. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02058-2 · Cited by 57
Cited by
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Self-citationShin, H.-C., Orton, M. R., Collins, D. J., Doran, S. J., & Leach, M. O. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.277 · Cited by 488
Self-citationImaging oxygenation of human tumours
Padhani, A. R., Krohn, K. A., Lewis, J. S., & Alber, M. (2007) · European Radiology · doi:10.1007/s00330-006-0431-y · Cited by 328
Self-citationLarge-scale retrieval for medical image analytics: A comprehensive review
Li, Z., Zhang, X., Müller, H., & Zhang, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2017.09.007 · Cited by 262
Metadata
- Authors
- Collins, D. J., & Padhani, A. R.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2004-09
- Volume
- 23
- Issue
- 5
- Pages
- 65-83
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2072246398
- Cited by
- 169
- References
- 4
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).