Robust heart rate estimation using wrist-based PPG signals in the presence of intense physical activities
Abstract
Heart rate tracking from a wrist-type photoplethysmogram (PPG) signal during intensive physical activities is a challenge that is attracting more attention thanks to the introduction of wrist-worn wearable computers. Commonly-used motion artifact rejection methods coupled with simple periodicity-based heart rate estimation techniques are incapable of achieving satisfactory heart rate tracking performance during intense activities. In this paper, we propose a two-stage solution. Firstly, we introduce an improved spectral subtraction method to reject the spectral components of motion artifacts. Secondly, instead of using heuristic mechanisms, we formalize the spectral peaks selection process as the shortest path search problem and validate its effectiveness. Analysis on the experimental results based on a published database shows that: (1) Our proposed method outperforms three other comparable methods with regards to heart rate estimation error. (2) The proposed method is a promising candidate for both offline cardiac health analysis and online heart rate tracking in daily life, even during intensive physical motions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Heart rate measurements from wearable devices are often less accurate during physical activity or cyclic wrist motions.
“Several studies have demonstrated that HR measurements from wearable devices are often less accurate during physical activity or cyclic wrist motions.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [38]
Wearable devices have higher error during activity than at rest.
“Our analyses reinforces the growing body of research demonstrating that wearable devices have higher error during activity than at rest.8,11,35,38,39”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [38]
All these motions range between 0.1 and 20 Hz, which is within the frequency range for heart rate (1-4 Hz).
“All these motions range between 0.1 and 20 Hz, which is within the frequency range for heart rate (1–4 Hz) [163].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [163]
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,748 · see citing works
A fast two-dimensional median filtering algorithm
Huang, T. S., Yang, G., & Tang, G. (1979) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1979.1163188 · Cited by 1,398 · see citing works
Zhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400 · see citing works
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Yousefi, R., Nourani, M., Ostadabbas, S., & Panahi, I. M. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2264358 · Cited by 229 · see citing works
Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running
Fukushima, H., Kawanaka, H., Bhuiyan, M. S., & OGURI, K. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346570 · Cited by 129 · see citing works
Chan, K. W., & Zhang, Y. (2003) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2002.1037314 · Cited by 104 · see citing works
Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography
Han, H., Kim, M.-J., & Kim, J. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352596 · Cited by 101 · see citing works
Role of Heart Rate Variability in the Early Diagnosis of Diabetic Autonomic Neuropathy in Children
Chessa, M., Butera, G., Lanza, G. A., Bossone, E., Delogu, A. B., Rosa, G. D., Marietti, G., Rosti, L., & Carminati, M. (2002) · Herz · doi:10.1007/s00059-002-2340-4 · Cited by 96 · see citing works
Yao, J., & Warren, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1617256 · Cited by 83 · see citing works
Cancellation of motion artifact induced by exercise for PPG-based heart rate sensing
Shimazaki, T., Hara, S., Okuhata, H., Nakamura, H., & Kawabata, T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944307 · Cited by 44 · see citing works
Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test
Silva, S. M. L. (2011) · Journal of Medical and Biological Engineering · doi:10.5405/jmbe.898 · Cited by 41 · see citing works
Flagged first, then by citations
1 of the 13 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
“Our analyses reinforces the growing body of research demonstrating that wearable devices have higher error during activity than at rest.(8,11,35,38,39) We further demonstrate that the directionality of the HR error is dependent on the activity type.”
BackgroundResultShcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
Military applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194 · see citing works
Mashhadi, M. B., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 144 · see citing works
Jarchi, D., & Casson, A. J. (2016) · Data · doi:10.3390/data2010001 · Cited by 120 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Thomson, E. A., Nuss, K. J., Comstock, A., Reinwald, S., Blake, S., Pimentel, R. E., Tracy, B. L., & Li, K. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1560644 · Cited by 112 · see citing works
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101 · see citing works
A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things
Naeini, E. K., Azimi, I., Rahmani, A. M., Liljeberg, P., & Dutt, N. D. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.04.074 · Cited by 90 · see citing works
Kwon, S., Kwon, Y., Kim, Y., Lim, H., Mahmood, M., & Yeo, W. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111981 · Cited by 76 · see citing works
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity
Jarchi, D., & Casson, A. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668763 · Cited by 58 · see citing works
Design, development and clinical validation of a wrist-based optical heart rate monitor
Preejith, S. P., Alex, A., Joseph, J., & Sivaprakasam, M. (2016) · 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533786 · Cited by 41 · see citing works
Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?
Martín-Escudero, P., Cabanas, A. M., Dotor-Castilla, M. L., Galindo-Canales, M., Miguel‐Tobal, F., Fernández, C., Fuentes, M. E., & Giannetti, R. (2023) · Bioengineering · doi:10.3390/bioengineering10020254 · Cited by 40 · see citing works
Cicone, A., & Wu, H. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00701 · Cited by 40 · see citing works
Rehman, R. Z. U., Chatterjee, M., Manyakov, N. V., Daans, M., Jackson, A., O’Brisky, A., Telesky, T., Smets, S., Berghmans, P.-J., Yang, D., et al. (2024) · Sensors · doi:10.3390/s24216826 · Cited by 36 · see citing works
Accuracy of wrist-worn wearable devices for determining exercise intensity
Ho, W.-T., Yang, Y.-J., & Li, T.-C. (2022) · Digital Health · doi:10.1177/20552076221124393 · Cited by 18 · see citing works
Reply: Matters Arising ‘Investigating sources of inaccuracy in wearable optical heart rate sensors’
Bent, B., Enache, O. M., Goldstein, B., Kibbe, W., & Dunn, J. P. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00409-4 · Cited by 17 · see citing works
Analysis of the Radial Pulse Wave and its Clinical Applications: A Survey
Yang, J., Yang, L., Liu, W., Du, S., Xu, L., He, G., Avolio, A. P., & Yao, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3128916 · Cited by 17 · see citing works
Masinelli, G., Dell’Agnola, F., Arza, A., & Atienza, D. (2021) · Sensors · doi:10.3390/s21082725 · Cited by 15 · see citing works
Vargas, J. M., Bahloul, M. A., & Laleg‐Kirati, T. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1100570 · Cited by 12 · see citing works
Accurate Heart Rate Monitoring Method During Physical Exercise From Photoplethysmography Signal
Thomas, A., & Gopi, V. P. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2886001 · Cited by 9 · see citing works
Intra-beat biomarker for accurate continuous non-invasive blood pressure monitoring
Abiri, A., Chou, E., Qian, C., Rinehart, J. B., & Khine, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-19096-6 · Cited by 10 · see citing works
Multi-parameter health monitoring watch
Fang, L., Chen, X., Fang, Z., Tong, K., Liu, J., Zheng-ling, H., & Li, J. (2017) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2017.8210807 · Cited by 7 · see citing works
Direct-Global Separation for Improved Imaging Photoplethysmography
Park, J., Sabharwal, A., & Veeraraghavan, A. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00186 · Cited by 7 · see citing works
Heart Rate Detection Using SVM Based on Video Imagery
Zeng, W., Sheng, Y., Hu, Q., Huo, Z., Zhang, Y., & Xie, Y. R. (2021) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2022.017748 · Cited by 7 · see citing works
Accuracy of Heart Rate and Energy Expenditure Estimations of Wrist-Worn and Arm-Worn Apple Watches
Nuss, K. J., Sanford, J. L., Archambault, L. J., Schlemer, E. J., Blake, S., Courtney, J. B., Hulett, N. A., & Li, K. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0061 · Cited by 5 · see citing works
Farhadi, M., Mashhadi, M. B., Essalat, M., & Marvasti, F. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/092627 · Cited by 5 · see citing works
An Adaptive Heart Rate Monitoring Algorithm for Wearable Healthcare Devices
Kuo, T.-H., Teng, C.-M., Wu, M., & Wen, C.-Y. (2021) · Electronics · doi:10.3390/electronics10172092 · Cited by 4 · see citing works
Prediction of Cardiovascular Diseases from Radial Pulse Wave Analysis
Kumar, S., Tayade, A., Shrivastava, A., & Ravi, B. (2024) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm62325.2024.10822076 · Cited by 2 · see citing works
Innovative Pulse Monitoring: Exploring Auscultation-Based Diagnostic Technique
Kumar, S., Tayade, A., Kumar, P., & Ravi, B. (2024) · International Conference on Biomedical and Bioinformatics Engineering (ICBBE) · doi:10.1145/3707127.3707146 · Cited by 2 · see citing works
Cicone, A., & Wu, H. (2017) · arXiv (Cornell University) · Cited by 1 · see citing works
Pulse controlled driver safety awareness system: A pilot study
Çeliker, D., Erçelik, C., & Duru, D. G. (2018) · Electric Electronics, Computer Science, Biomedical Engineerings' Meeting (EBBT) · doi:10.1109/ebbt.2018.8391435
Investigating Sources of Inaccuracy in Wearable Optical Heart Rate Sensors (Preprint)Preprint
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. (2020) · doi:10.2196/preprints.18126
Ramadhan, R., & Akbar, I. A. (2024) · International Seminar on Intelligent Technology and Its Applications · doi:10.1109/isitia63062.2024.10668366
Heart Rate Imputation Using Accelerometers for Wearable Devices
Choe, B., Kim, H. Y., & Uhm, J. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781795
Wavelet Decomposition with Machine Learning for PPG Signal Quality Detection
Qaisar, S. M., Triantafyllopoulos, A., Khalifa, T., & Kulaglić, A. (2025) · International Women in Data Science Conference at Prince Sultan University (WiDS PSU) · doi:10.1109/wids-psu64963.2025.00049
Noninvasive Estimation of Glycated Hemoglobin: A Comprehensive Review of Emerging Technologies
Saini, S. K., Tiwari, S., Joshi, A. M., & Maddila, R. K. (2026) · IETE Technical Review · doi:10.1080/02564602.2026.2701257
- Authors
- Zong, C., & Jafari, R.
- Affiliations
- The University of Texas at Dallas (US)
- Venue
- 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2015-08
- Volume
- 2015
- Pages
- 8078-8082
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2294523693
- Cited by
- 39
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 7 · 2020: 2 · 2019: 5 · 2018: 4 · 2017: 5 · 2016: 3 · 2015: 1
- FWCI
- 8.34
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart rate estimation, photoplethysmography, wrist-worn sensors, motion artifact rejection, spectral subtraction, shortest path search, wearable devices, physical activity, cardiac health monitoring
- MeSH terms
- Algorithms, Heart Rate, Humans, Signal Processing, Computer-Assisted, Wrist, Exercise, Artifacts, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review