The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Compliant actuation of rehabilitation robots
Abstract
This article discusses the pros and cons of compliant actuation for rehabilitation robots on the example of LOPES, focusing on the cons. After illustrating the bandwidth limitations, a new result has been derived: if stability in terms of passivity of the haptic device is desired, the renderable stiffness is bounded by the stiffness of the SEA's elastic component. In practical experiments with the VMC, the aforementioned limitations affected the control performance. Desired gait modifications were not tracked exactly, because the subjects were able to deviate from the prescribed pattern even in the stiffest possible configuration. Despite the limitations, the practical experiments also demonstrated the general effectiveness of the realization. Manipulation of selected gait parameters is possible, whereby other parameters are left unaffected. This high selectivity is made possible by the low level of undesired interaction torques, which is achieved by elastic decoupling of motor mass and a lightweight exoskeleton. The discrepancy between theoretical bounds and rendered stiffness indicated that healthy subjects might represent a stabilizing component of the coupled system, which could be different for patients. In light of the theoretical stability analysis and with the focus on patients, the LOPES actuation was slightly modified. The robot was equipped with stiffer springs to obtain sufficient stiffness and to ensure stability without relying on stabilizing effects of the human. For this application, the disadvantages of compliant actuation can thus be tolerated or dealt with, and they are small compared with the advantages. Given that a rehabilitation robot, in the first place, is supposed to imitate therapist action, the limitations of bandwidth and stiffness do not pose severe problems. In contrast, safety and backdrivability are highly relevant, and they can be ensured easier with a compliant actuator. Therefore, we conclude that compliant actuation and a lightweight exoskeleton provide effective means to accomplish the desired AAN behavior of a rehabilitation robot. The next step is to evaluate the robot behavior, control performance, and therapeutic effectiveness in patient studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to robotics: Mechanics and control
Merat, F. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087086 · Cited by 2,398
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Self-citationTreadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Effects of Intensity of Rehabilitation After Stroke: A Research Synthesis
Kwakkel, G., Wagenaar, R. C., Koelman, T. W., Lankhorst, G. J., & Koetsier, J. C. (1997) · Stroke · doi:10.1161/01.str.28.8.1550 · Cited by 589
Virtual Model Control: An Intuitive Approach for Bipedal Locomotion
Pratt, J., Chew, C.-M., Torres, A., Dilworth, P., & Pratt, G. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067309 · Cited by 548
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 2×
“The concept, construction, and functionality of these joints are described extensively in [9].”
BackgroundMethodHusemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374
Cai, L. L., Fong, A. J., Otoshi, C. K., Liang, Y., Burdick, J. W., Roy, R. R., & Edgerton, V. R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2266-06.2006 · Cited by 344
Pohl, M., Werner, C., Holzgraefe, M., Kroczek, G., Wingendorf, I., Hoölig, G., Koch, R., & Hesse, S. (2007) · Clinical Rehabilitation · doi:10.1177/0269215506071281 · Cited by 340
Israel, J. F., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2006) · Physical Therapy · doi:10.2522/ptj.20050266 · Cited by 322
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
Design and analysis of series elasticity in closed-loop actuator force control
Robinson, D. W. (2000) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 265
Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903922 · Cited by 249
Robot-aided sensorimotor arm training improves outcome in patients with chronic stroke
Ferraro, M., Palazzolo, J. J., Krol, J., Krebs, H. I., Hogan, N., & Volpe, B. T. (2003) · Neurology · doi:10.1212/01.wnl.0000095963.00970.68 · Cited by 242
Control law design for haptic interfaces to virtual reality
Adams, R. J., & Hannaford, B. (2002) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.974333 · Cited by 172
Passive and accurate torque control of series elastic actuators
Vallery, H., Ekkelenkamp, R., van der Kooij, H., & Buss, M. (2007) · 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2007.4399172 · Cited by 169
Self-citationKineAssist: A Robotic Overground Gait and Balance Training Device
Peshkin, M. A., Brown, D. A., Santos-Munné, J. J., Makhlin, A., Lewis, E., Colgate, J. E., Patton, J. L., & Schwandt, D. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501094 · Cited by 157
Tools for understanding and optimizing robotic gait training
Reinkensmeyer, D. J., Aoyagi, D., Emken, J. L., Galvez, J. A., Ichinose, W. E., Kerdanyan, G., Maneekobkunwong, S., Minakata, K., Nessler, J. A., Weber, R., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0073 · Cited by 150
The Role of Timing and Intensity of Rehabilitation Therapies
Teasell, R. W., Bitensky, J., Salter, K. L., & Bayona, N. A. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/etdp-6dr4-d617-vmvf · Cited by 139
Late motor processing in low-impedance robots: impedance control of series-elastic actuators
Pratt, G. A., Willisson, P., Bolton, C., & Hofman, A. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1384410 · Cited by 128
LOPES : Selective Control of Gait Functions During the Gait Rehabilitation of CVA Patients
Ekkelenkamp, R., Veneman, J. F., & van der Kooij, H. (2005) · doi:10.1109/icorr.2005.1501120 · Cited by 70
Self-citationSelective control of a subtask of walking in a robotic gait trainer(LOPES)
van Asseldonk, E. H. F., Ekkelenkamp, R., Veneman, J. F., van der Helm, F. C. T., & van der Kooij, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428522 · Cited by 58
Self-citationComplementary Limb Motion Estimation based on Interjoint Coordination: Experimental Evaluation
Vallery, H., Ekkelenkamp, R., Buss, M., & van der Kooij, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428516 · Cited by 30
Self-citationVallery, H., & BUSS, M. J. (2007) · at - Automatisierungstechnik · doi:10.1524/auto.2007.55.10.503 · Cited by 4
Self-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“…user intent or invalid sensor inputs [24,67,116,118,121, 136,176,214,239], unstable interactions with the user and environment [60,107,138,181,184,202], actuation failures due to overloading/saturating the actuator [136,170,214], failure of an underactuated system to achieve its desired state,…”
InfluentialSelf-citationA Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Human–Robot Interaction Control of Rehabilitation Robots With Series Elastic Actuators
Yu, H., Huang, S., Chen, G., Pan, Y., & Guo, Z. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2457314 · Cited by 356
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
A Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance Robots
Calanca, A., Muradore, R., & Fiorini, P. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2465849 · Cited by 320
Metadata
- Authors
- Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H.
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2008-09
- Volume
- 15
- Issue
- 3
- Pages
- 60-69
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W2116767351
- Cited by
- 448
- References
- 26
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.