Cited by 2Neuroscience and Neural EngineeringTactile and Sensory InteractionsAnalog and Mixed-Signal Circuit Design

Efficient Modeling and Calibration of Multi-Electrode Stimuli for Epiretinal Implants

Vasireddy, Praful K., Gogliettino, Alex R., Brown, Jeff B., Vilkhu, Ramandeep S., Madugula, Sasi S., Phillips, A. J., Mitral, Subhasish, Hottowy, Pawel +4 more·2023·2023 11th International IEEE/EMBS Conference on Neural Engineering (NER)

Abstract

Epiretinal implants are designed to restore visual function by direct stimulation of retinal ganglion cells (RGCs) with a multi-electrode array. However, the efficacy of present-day epiretinal implants is limited by indiscriminate, simultaneous activation of many RGCs of different types that normally convey distinct visual information, resulting in highly unnatural visual signals. Even with high-density multi-electrode arrays in a laboratory setting, single-electrode stimulation often cannot target an individual cell selectively. A possible solution is to use spatially patterned multi-electrode stimulation. Previous studies have demonstrated enhanced selectivity using such stimuli, but a general framework for characterizing the responses of RGCs to stimulation by multiple electrodes has yet to be realized. Here we propose a generalizable model for the response of a neuron to multi-electrode stimuli, and demonstrate that it can be used to systematically and efficiently improve the selectivity of epiretinal stimulation. The efficacy of the model and of multi-electrode stimuli is validated using three-electrode triplet stimulation. The model assumes that there are several possible activation sites on each cell where a spike can originate, and that the probability of activation at each site is determined by a weighted sum of the currents applied on the electrodes. The multi-site model provides excellent fits to experimental data as well as an interpretable mechanism of multi-electrode activation. Additionally, since the model has few parameters, it permits efficient closed-loop calibration. An optimal experimental design is presented and validated for quickly learning the model parameters and identifying multi-electrode stimuli that are more selective than can be achieved with single-electrode stimuli. The model and closed-loop algorithm could potentially be used to optimize the selectivity of other neural interfaces.

Integrity signals

Registry

Crossref · 10.1109/ner52421.2023.10123907

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Alternative stimulation strategies have not been validated in vivo in humans using perceptually relevant pulse-train stimulation, and most do not address the substantial day-to-day variability in cortical responses that limits clinical reliability.

    “While alternative stimulation strategies have been proposed [25–39], none have been validated in vivo in humans using perceptually relevant pulse-train stimulation, and most do not address the substantial day-to-day variability in cortical responses that limits clinical reliability.”
  • Although the greedy algorithm is nearly optimal for a single-electrode dictionary, the reconstruction performance of an artificial retina could be improved by enhancing the dictionary (e.g. by using calibrated, optimized multi-electrode stimulation patterns).

    “Thus, although the greedy algorithm is nearly optimal for a single-electrode dictionary, the reconstruction performance of an artificial retina could be improved by enhancing the dictionary (e.g. by using calibrated, optimized multi-electrode stimulation patterns; Jepson et al., 2014; Vasireddy et al., 2023).”

    From Precise control of neural activity using dynamically optimized electrical stimulation (2024) · cites this paper as Vasireddy et al., 2023

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Vasireddy, P. K., Gogliettino, A. R., Brown, J. B., Vilkhu, R. S., Madugula, S. S., Phillips, A. J., Mitral, S., Hottowy, P., Sher, A., Litke, A., Shah, N. P., & Chichilnisky, E. J.
Affiliations
  • Stanford University (US)
  • Stanford University
  • AGH University of Science and Technology
  • University of California, Santa Cruz (US)
Venue
2023 11th International IEEE/EMBS Conference on Neural Engineering (NER)
Publisher
IEEE
Published
2023-04-24
Pages
1-4
ISSN
1948-3554 (ISSN-L)
OpenAlex
W4377089391
Cited by
2
References
22
Citations by year
2026: 1 · 2024: 1
FWCI
2.39
Type
conference paper
Language
en
Open access
closed
Locations
International IEEE/EMBS Conference on Neural Engineering (publishedVersion)
Funders
  • NSF (1828993)
  • NIH (EY021271 (EJC))
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
epiretinal implants, multi-electrode stimulation, retinal ganglion cells, stimulation selectivity, closed-loop calibration, optimal experimental design, neural interfaces, visual prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review