Walking Faster and Farther With a Soft Robotic Exosuit: Implications for Post-Stroke Gait Assistance and Rehabilitation

Open access
Awad, Louis N., Kudzia, Pawel, Revi, Dheepak Arumukhom, Ellis, Terry D., Walsh, Conor J.·2020·IEEE Open Journal of Engineering in Medicine and Biology

Abstract

OBJECTIVE: Soft robotic exosuits can improve the mechanics and energetics of walking after stroke. Building on this prior work, we evaluated the effects of the first prototype of a portable soft robotic exosuit. METHODS: Exosuit-induced changes in the overground walking speed, distance, and energy expenditure of individuals post-stroke were evaluated statistically with alpha set to 0.05 and compared to minimal clinically important difference scores. RESULTS: 5kg exosuit did not substantially modify walking speed, distance, or energy expenditure when worn unpowered. In contrast, when the exosuit was powered on to provide an average 22.87±0.58 %bodyweight of plantarflexor force assistance during the paretic limb's stance phase and assist the paretic dorsiflexors during swing phase to reduce drop-foot, study participants walked a median 0.14±0.06 m/s faster during the 10-meter walk test and traveled 32±8 m farther during the six minute walk test. CONCLUSIONS: Individuals post-stroke can leverage the paretic plantarflexor and dorsiflexor assistance provided by soft robotic exosuits to achieve clinically-meaningful increases in speed and distance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ojemb.2020.2984429

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. (A) Total 6-minute walk test (6MWT) distances for each condition. Right – Difference in 6MWT distance between the no exosuit condition and each of the two unpowered exosuit conditions and the powered exosuit condition. Circles represent individual study participants. (B) Distance per minute of the 6MWT for each condition. The minimal clinically important difference (MCID) is depicted in each plot with the dashed horizontal lines. Significance (}{}$P < 0.05$) relative to }{}$^\ast$no exosuit and }{}$^\dagger$unpowered exosuit conditions. Medians and sIQR are reported.
Figure 1. (A) Total 6-minute walk test (6MWT) distances for each condition. Right – Difference in 6MWT distance between the no exosuit condition and each of the two unpowered exosuit conditions and the powered exosuit condition. Circles represent individual study participants. (B) Distance per minute of the 6MWT for each condition. The minimal clinically important difference (MCID) is depicted in each plot with the dashed horizontal lines. Significance (}{}$P < 0.05$) relative to }{}$^\ast$no exosuit and }{}$^\dagger$unpowered exosuit conditions. Medians and sIQR are reported.CC BY · PubMed Central
Figure 2. (A) Usual and (B) Maximum walking speeds, as measured using the 10-meter walk test, are shown for each condition tested. Right – The difference in each speed between the no exosuit condition and each of the two unpowered exosuit conditions and the powered exosuit condition. Circles represent individual study participants. The minimal clinically important difference (MCID) is depicted in each plot with the dashed horizontal lines. Significance (}{}$P < 0.05$) relative to }{}$^\ast$no exosuit and }{}$^\dagger$unpowered exosuit conditions. Medians and sIQR are reported.
Figure 2. (A) Usual and (B) Maximum walking speeds, as measured using the 10-meter walk test, are shown for each condition tested. Right – The difference in each speed between the no exosuit condition and each of the two unpowered exosuit conditions and the powered exosuit condition. Circles represent individual study participants. The minimal clinically important difference (MCID) is depicted in each plot with the dashed horizontal lines. Significance (}{}$P < 0.05$) relative to }{}$^\ast$no exosuit and }{}$^\dagger$unpowered exosuit conditions. Medians and sIQR are reported.CC BY · PubMed Central
Figure 3. (A) Energy expenditure, measured with indirect calorimetry as oxygen utilization per kilogram of bodyweight and minute and (B) energy cost of walking, measured as oxygen utilization per kilogram of bodyweight and meter walked are presented for each condition. Medians and sIQR are reported.
Figure 3. (A) Energy expenditure, measured with indirect calorimetry as oxygen utilization per kilogram of bodyweight and minute and (B) energy cost of walking, measured as oxygen utilization per kilogram of bodyweight and meter walked are presented for each condition. Medians and sIQR are reported.CC BY · PubMed Central
Figure 4. (A) Overview of the soft robotic exosuit used to augment paretic ankle plantarflexion (PF) and dorsiflexion (DF) function during post-stroke hemiparetic walking. (B) Exemplar force profiles for PF and DF assistance are shown. The onset timing and peak magnitude of PF assistance and the onset and off timing of DF assistance were commanded as described in previous work [5]. Assistance timing was delivered as a function of the paretic and nonparetic gait cycles defined by the detection of paretic (green) and nonparetic (red) foot strike and foot off. Photo in panel A courtesy of Rolex Foundation.
Figure 4. (A) Overview of the soft robotic exosuit used to augment paretic ankle plantarflexion (PF) and dorsiflexion (DF) function during post-stroke hemiparetic walking. (B) Exemplar force profiles for PF and DF assistance are shown. The onset timing and peak magnitude of PF assistance and the onset and off timing of DF assistance were commanded as described in previous work [5]. Assistance timing was delivered as a function of the paretic and nonparetic gait cycles defined by the detection of paretic (green) and nonparetic (red) foot strike and foot off. Photo in panel A courtesy of Rolex Foundation.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 36 references

Research works printed but not linked: 1

  1. mcdonald, 2014, Multiple Comparisons - Handbook of Biological Statistics

Cited by

Sorted by citations

Items 101–111 of 111

Metadata

Authors
Awad, L. N., Kudzia, P., Revi, D. A., Ellis, T. D., & Walsh, C. J.
Affiliations
  • Boston University (US)
  • Harvard University (US)
Corresponding author
  • Awad, Louis N.
  • Walsh, Conor J.
Venue
IEEE Open Journal of Engineering in Medicine and Biology
Published
2020
Volume
1
Pages
108-115
ISSN
2644-1276 (ISSN-L)
OpenAlex
W3014201768
Cited by
111
References
36
Citations by year
2026: 9 · 2025: 19 · 2024: 17 · 2023: 19 · 2022: 23 · 2021: 18 · 2020: 6
FWCI
5.18
Type
journal article
Language
en
Open access
Locations
  • IEEE Open Journal of Engineering in Medicine and Biology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Institutes of Health (R01HD088619)
  • American Heart Association (18TPA34170171)
  • Wyss Institute at Harvard University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
stroke rehabilitation, gait assistance, walking speed, walking distance, energy expenditure, foot drop, paretic limb, powered exoskeleton, overground walking

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review