On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper examines winding faults as short circuit for permanent magnet synchronous motor (PMSM). The study is carried out by means of stator current harmonic analysis. dq0 current transformation is also used to diagnose the state of the machine, and Wavelet approach is proposed to extend the analysis to the transitory of the failure. Experimental results for the full range of speeds have been obtained, which demonstrate the claims of the paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [41]
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227 · cited 1×
“As it has been well demonstrated [ 9 ] [10] this transformation is useful in case of variations of base frequency or current amplitude.”
ResultCondition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 1×
“Short circuit failures are the most important in PMSM [ 4 ], thus, that is the biggest failure cause and also for the damages that it would make in the applications of PMSM.”
BackgroundDetection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394 · cited 1×
“The harmonic order is directly related with the slot number twice the polar step, and his magnitude depends on the distribution winding factor [ 6 ], [7].”
BackgroundHenao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“The harmonic order is directly related with the slot number twice the polar step, and his magnitude depends on the distribution winding factor [6], [ 7 ].”
BackgroundPerformance of interior permanent magnet motor drive over wide speed range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/60.986441 · Cited by 185
Performance of Interior Permanent Magnet Motor Drive over Wide Speed Range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4311984 · Cited by 117 · cited 1×
“Yet, the speed oscillations will depend on the bandwidth of speed controllers [ 8 ], which can attenuate or modify the effect of the failure.”
BackgroundOperation of a fault tolerant PM drive for an aerospace fuel pump application
Haylock, J. A. (1997) · Eighth International Conference on Electrical Machines and Drives · doi:10.1049/cp:19971053 · Cited by 101 · cited 2×
“In high security applications short circuit fault current in the machine is limited to rated value by designing the machine with a high. phase inductance [ 1 ].”
BackgroundOperation of a fault tolerant PM drivefor an aerospace fuel pump application
Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1998) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19982164 · Cited by 95
Investigation of a fault tolerant and high performance motor drive for critical applications
Ertuğrul, N., Soong, W. L., Valtenbergs, S., & Chye, H. (2002) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2001.949653 · Cited by 26 · cited 1×
“In such applications it is advantageous to use a drive capable of continuing to operate in the presence of any single point failure [1], [ 2 ].”
BackgroundOjo, O., Osaloni, O. O., & Kshirsagar, P. (2003) · Conference record · doi:10.1109/ias.2002.1043738 · Cited by 18 · cited 1×
“In many of these critical drive applications, it is required that the drive comprising the motor and the converter, under fault conditions, operates stably and meets base drive needs for a period of time before the system can be (self) – repaired [ 3 ].”
Background
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
“In [ 19 ], for a wide speed range of operation, it has been found that rms values of the lower detail levels (levels 1–3) reflected the fault unambiguously.”
BackgroundMethodFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
“Recently, this analysis has been extended to PMSM machines, which present the additional problem of the synchronism of the faulty frequencies regarding the motor speed [11].”
MethodSelf-citationZafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“Stator current sequences and the impact of different faults on these components are investigated in [24] and [41].”
BackgroundFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
“It can clearly show the frequency distribution of the signal, where the amplitude and frequency of harmonic components can be used as the features of different faults [54].”
Background
Metadata
- Authors
- Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Ortega, J.A.
- Venue
- 2007 IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 2007
- Pages
- 1936-1941
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2136389802
- Cited by
- 63
- References
- 11
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 4
- FWCI
- 5.72
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Electronics Specialists Conference (PESC) (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, short circuit detection, winding faults, wavelet analysis, fault transients, condition monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.