On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper examines winding faults as short circuit for permanent magnet synchronous motor (PMSM). The study is carried out by means of stator current harmonic analysis. dq0 current transformation is also used to diagnose the state of the machine, and Wavelet approach is proposed to extend the analysis to the transitory of the failure. Experimental results for the full range of speeds have been obtained, which demonstrate the claims of the paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [41]
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227 · cited 1×
“As it has been well demonstrated [ 9 ] [10] this transformation is useful in case of variations of base frequency or current amplitude.”
ResultCondition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 1×
“Short circuit failures are the most important in PMSM [ 4 ], thus, that is the biggest failure cause and also for the damages that it would make in the applications of PMSM.”
BackgroundDetection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394 · cited 1×
“The harmonic order is directly related with the slot number twice the polar step, and his magnitude depends on the distribution winding factor [ 6 ], [7].”
BackgroundHenao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“The harmonic order is directly related with the slot number twice the polar step, and his magnitude depends on the distribution winding factor [6], [ 7 ].”
BackgroundPerformance of interior permanent magnet motor drive over wide speed range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/60.986441 · Cited by 185
Performance of Interior Permanent Magnet Motor Drive over Wide Speed Range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4311984 · Cited by 117 · cited 1×
“Yet, the speed oscillations will depend on the bandwidth of speed controllers [ 8 ], which can attenuate or modify the effect of the failure.”
BackgroundOperation of a fault tolerant PM drive for an aerospace fuel pump application
Haylock, J. A. (1997) · Eighth International Conference on Electrical Machines and Drives · doi:10.1049/cp:19971053 · Cited by 101 · cited 2×
“In high security applications short circuit fault current in the machine is limited to rated value by designing the machine with a high. phase inductance [ 1 ].”
BackgroundOperation of a fault tolerant PM drivefor an aerospace fuel pump application
Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1998) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19982164 · Cited by 95
Investigation of a fault tolerant and high performance motor drive for critical applications
Ertuğrul, N., Soong, W. L., Valtenbergs, S., & Chye, H. (2002) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2001.949653 · Cited by 26 · cited 1×
“In such applications it is advantageous to use a drive capable of continuing to operate in the presence of any single point failure [1], [ 2 ].”
BackgroundOjo, O., Osaloni, O. O., & Kshirsagar, P. (2003) · Conference record · doi:10.1109/ias.2002.1043738 · Cited by 18 · cited 1×
“In many of these critical drive applications, it is required that the drive comprising the motor and the converter, under fault conditions, operates stably and meets base drive needs for a period of time before the system can be (self) – repaired [ 3 ].”
Background
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
“In [ 19 ], for a wide speed range of operation, it has been found that rms values of the lower detail levels (levels 1–3) reflected the fault unambiguously.”
BackgroundMethodFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
“Recently, this analysis has been extended to PMSM machines, which present the additional problem of the synchronism of the faulty frequencies regarding the motor speed [11].”
MethodSelf-citationZafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“Stator current sequences and the impact of different faults on these components are investigated in [24] and [41].”
BackgroundFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
“It can clearly show the frequency distribution of the signal, where the amplitude and frequency of harmonic components can be used as the features of different faults [54].”
BackgroundAubert, B., Regnier, J., Caux, S., & Alejo, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348934 · Cited by 137
Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Wang, C., Liu, X., & Chen, Z. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2318207 · Cited by 85
Chen, Z., Liang, D., Jia, S., Yang, L., & Yang, S. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3255249 · Cited by 72
“Fourier transform [1], wavelet transform [2], Hilbert Huang”
BackgroundMethodUllah, Z., & Hur, J. (2018) · Energies · doi:10.3390/en11123309 · Cited by 77
“The impacts of ITSF on stator-current-sequences components are investigated in various studies, such as [23,41,42].”
BackgroundMethodAnalysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
Yuan, Q., Zafarani, M., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626264 · Cited by 51
“back, the continuous wavelet transform is used to analyze the phase current [22], phase voltage [23], q-axis voltage reference [24] for diagnosis in transient states.”
MethodMaraaba, L. S., Al‐Hamouz, Z., Milhem, A. S., & Abido, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2923746 · Cited by 47
Pietrzak, P., & Wolkiewicz, M. (2021) · Energies · doi:10.3390/en14061630 · Cited by 40
“Additionally, damage to the stator winding may result in an increase in the slot harmonics, calculated using the following equation [39]:”
MethodZeng, C., Huang, S., Yang, Y., & Wu, D. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0865 · Cited by 38
Stator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29
Self-citationGarcía, J. R., Romeral, L., Ortega, J. A., & Rosero, E. (2008) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2008.4522706 · Cited by 31
“Now, the biggest harmonic of FFT is the 9th harmonic (900 Hz in this case).”
BackgroundInfluentialSelf-citationRosero, J., Espinosa, A. G., Cusido, J., Ortega, J. A., & Romeral, L. (2008) · 2008 IEEE Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2008.4547070 · Cited by 25
“From years ago, the failure detection in a motor is studied by analyzing the stator current harmonic by means of FFT [5].”
Self-citationAn effective method for detection of stator fault in PMSM with 1D-LBP
Mi̇naz, M. R. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.07.013 · Cited by 23
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883929 · Cited by 26
“In order to compromise on the long computation time and cost effectiveness of the tool, there has been tremendous work done in fault modeling of PMSM using analytical or equivalent electric/magnetic circuit approach which includes Clarke-Park transformation methods [10]-[12].”
MethodStator Short Circuits Detection in PMSM by means of Higher Order Spectral Analysis (HOSA)
Rosero, J., Ortega, J., Urresty, J., Cardenas, J., & Romeral, L. (2009) · 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802779 · Cited by 22
“But, FFT cannot be applied in no-stationary signals [1, 10].”
BackgroundSelf-citationAlvarez‐Gonzalez, F., Griffo, A., & Wang, B. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591661 · Cited by 17
Current Signature Modeling of Surface-Mounted PMSM Drives With Current Sensors Faults
Attaianese, C., D’Arpino, M., Monaco, M. D., & Noia, L. P. D. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3282314 · Cited by 17
“Theyhaveapproachedmainlythe detectionofopenphasefault[6],[7],statorwindinginter-turn shortcircuit[8],[9],[10],[11],[12],rotordemagnetization[13], [14],[15],airgapeccentricity[16],[17],[18],[19].”
Shen, T., Kılıç, A., Thulfaut, C., & Reuss, H.-C. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915161 · Cited by 16
“The reason of this effect is discussed in [12].”
BackgroundMethodNavarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Detection and analysis of winding and demagnetization faults in PMSM based marine propulsion motors
Ahsanullah, K., Jeyasankar, E., Panda, S. K., Ramakrishna, S., & Nadarajan, S. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8002050 · Cited by 15
“To overcome this disadvantage, researchers developed short-time Fourier transform (STFT) [5] or a more sophisticated wavelet transform [6] to determine faults.”
MethodJeong, H., Moon, S., Lee, J., & Kim, S. W. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474745 · Cited by 13
“The MCSA uses frequency analysis such as fast Fourier transform (FFT), short time Fourier transform (STFT), and wavelet transform (WT) [15]-[17].”
MethodHenriques, K., Laadjal, K., & Cardoso, A. J. M. (2022) · International Electronic Conference on Machines and Applications (IECMA) · doi:10.3390/iecma2022-12884 · Cited by 14
“This represents a signal as a combination of multiple sinusoidal functions, and clearly shows the frequency distribution of a signal, representing the amplitude and frequency of the components of harmonics, which can be used to define machine malfunctions [13].”
BackgroundModeling and harmonic analysis of a permanent magnet synchronous machine with turn-to-turn fault
Härsjö, J., & Bongiorno, M. (2015) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2015.7309189 · Cited by 9
Sensitive Inter-Tum Fault Identifcation in Induction Motors Using Deep Learning Based Methods
Husari, F., & Seshadrinath, J. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070334 · Cited by 9
“Some of these techniques from the traditional ones to the most recent are Fast Fourier Transform (FFT) [3], Short Time Fourier Transform (STFT) [4], Wavelet family [5-7], Winding Function Approach (WFA), Dynamic Mesh Reluctance Approach and Magnet Equivalent Circuit [8-10].”
MethodFault Detection in a Current Controlled PM Drive Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., & Meibody‐Tabar, F. (2010) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2010.5616894 · Cited by 8
An approach for on-line electrical machine winding inter-turn fault detection
Zhang, M. Q., & Tseng, K. J. (2014) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2014.6939379 · Cited by 8
“To broaden the fault detection range, the extensive time-frequency techniques such as short-time Fourier transform (STFT) [5] or more sophisticated wavelet transform [6] are developed.”
MethodRefaat, S. S., Abu‐Rub, H., Mohamed, A., & Trabelsi, M. (2017) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2017.7913102 · Cited by 8
Upadhyay, A., Alaküla, M., & Márquez-Fernández, F. J. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926678 · Cited by 10
Yuan, Q., Zafarani, M., & Akin, B. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854673 · Cited by 7
Interturn short fault diagnosis of a PMSM using voltage residual components
Moon, S., Jeong, H., & Kim, S. W. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793572 · Cited by 6
Zhao, C., Li, Y., Wessner, M., Rathod, C., & Pisu, P. (2020) · Annual Conference of the PHM Society · doi:10.36001/phmconf.2020.v12i1.1291 · Cited by 9
Inter-turns fault diagnosis for surface permanent magnet based marine propulsion motors
Ahsanullah, K., Panda, S. K., Ramakrishna, S., & Nadarajan, S. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846131 · Cited by 8
“To overcome this disadvantage, researchers developed short-time Fourier transform (STFT) [6] or a more sophisticated wavelet transform [7] to determine faults.”
MethodAfshar, M., Abdi, S., Mortazavizadeh, S. A., Fajri, P., & Ebrahimi, M. (2020) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie45063.2020.9152557 · Cited by 5
“It can also be adapted to a wide range of frequency and temporal resolution and has recently been used for detecting the ITSC faults in the stator winding of permanent magnet synchronous machines [10].”
MethodFailure diagnosis of brushless DC motor with rotor magnet defect
Ishikawa, T., Seki, Y., Kurita, N., & Matsuura, T. (2011) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2011.5994841 · Cited by 5
“Moreover, the shortcircuit failures of the stator winding in permanent magnet synchronous motor have been analyzed using the Wavelet transform [3].”
MethodPietrzak, P., & Wolkiewicz, M. (2022) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.24425/bpasts.2022.140556 · Cited by 5
Swathika, S., Praveen Kumar, N., & Isha, T. B. (2018) · IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology · doi:10.1109/rteict42901.2018.9012428 · Cited by 6
Fault-tolerant control of PMSM based on second-order sliding mode
Zeghlache, A., Mekki, H., Djerioui, A., Benkhoris, M. F., & Dahmane, N. (2022) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem55808.2022.10043923 · Cited by 4
“The presence of the electrical and magnetic faults leads to asymmetry of the PMSM and produces harmonics in the stator-current spectrum [13], so the stator current quadratic and direct (id and iq) are expanded by a sinusoidal component of pulsation ωi = 2π.”
BackgroundJeong, H., Moon, S., Lee, H., & Kim, S. W. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062351 · Cited by 4
“Many researchers have studied ISCF detections using motor current signature analysis (MCSA) [7], [8], model-based method [9], [10], data-based method [11], [12], and signalbased method [13]–[16].”
MethodPietrzak, P., Wolkiewicz, M., & Kotarski, J. (2024) · Electronics · doi:10.3390/electronics13152975 · Cited by 3
Urresty, J.-C., Riba, J., Ortega, J. A., & Cárdenas, J. J. (2009) · TECNALIA Publications (Fundación TECNALIA Research & Innovation) · Cited by 3
Self-citationRosero, J., Cusidó, J., García, A., Romeral, L., & Ortega, J. A. (2007) · IEEE International Symposium on Intelligent Signal Processing, · doi:10.1109/wisp.2007.4447494 · Cited by 3
“bearings and eccentricity fault detection for a permanent magnet [5] J.”
BackgroundMethodSelf-citationAhsanullah, K., Panda, S. K., & Jeyasankar, E. (2017) · IEEE International Magnetics Conference · doi:10.1109/intmag.2017.8007831 · Cited by 3
Mınaz, M. R. (2020) · Bitlis Eren Üniversitesi Fen Bilimleri Dergisi · doi:10.17798/bitlisfen.595943 · Cited by 2
Yan, D., Shen, T., Kılıç, A., & Reuss, H.-C. (2019) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2019.8700411 · Cited by 3
“As mentioned in [8], the fundamental component of phase currents decreases and third harmonics increases 0.”
BackgroundMethodZhang, W., Han, Y., Tang, Y., Liu, J., & Yu, J. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344509 · Cited by 1
“The phase current diagnostic method (MCSA) is often used to detect faults in PMSM. J. A. Rosero [3] proposed the theory of stator current spectrum and the concept of synchronous harmonic current, and proved the feasibility of using synchronous harmonic current to diagnose low-order short-circuit…”
MethodSpatial Magnetic Field Multi-Frequency Analysis of PMSM with Inter-Turn Short Fault
Zeng, C., Du, X., Ma, H., Tian, L., Chen, C., & Song, J. (2024) · International Conference on Energy Systems and Electrical Power (ICESEP) · doi:10.1109/icesep62218.2024.10651743 · Cited by 1
“In order to effectively extract frequency features from the signal, short-time Fourier transform [9] and wavelet transform [10-12] and other time-frequency analysis methods have been adopted.”
MethodFemia, A., Cagliari, G. A., Sala, G., Vancini, L., Rizzoli, G., Mengoni, M., Zarri, L., & Tani, A. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3618013 · Cited by 2
“Transformations,suchasthefastFouriertransform[16], [17],wavelettransform[18],andHilberttransform[19],areused to extract important features of the faults in the time domain or time–frequency domain.”
Li, D., Zhu, M., Zhao, Y., & Lin, S. (2025) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-025-02289-0 · Cited by 4
“Rosero et al. [23] analyzed the stator current and q-axis current of a faulty motor under different fault degrees.”
FAULT DETECTION OF BRUSHLESS PERMANENT MAGNET MACHINE DRIVES
Liu, B. (2014) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Taghipour‐Gorjikolaie, M., Razavi, S. M., & Shamsinejad, M. A. (2015)
Fault Anticipation Software System architecture for aircraft EMA
Delgado-Prieto, M., Navarro, L., García, A., & Ortega, J. A. (2009) · TECNALIA Publications (Fundación TECNALIA Research & Innovation)
Self-citationElectrical machine fault analysis and modelling by using electromagnetic approach
Zhang, M. Q. (2016) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/69010 · Cited by 1
“Since then, other transforms of stator current are also fund to detect this fault, such as current’s park vector [17], current’s extended park vector [18], envelop of the stator current [19], stator current in multiple reference frame [20], and the wavelet transform [21, 22].”
BackgroundCondition Monitoring Of Permanent Magnet Synchronous Motor- A Review
(2021) · i-manager’s Journal on Instrumentation and Control Engineering · doi:10.26634/jic.8.1.17698
Siddiqui, K. M., & Bakhsh, F. I. (2021) · Journal of University of Shanghai for Science and Technology · doi:10.51201/jusst/21/07301
Fault Tolerant Control of PMSM based on Improved Exponential ESO
Zeghlache, A., Mekki, H., Djerioui, A., Benkhoris, M. F., & Benzaoui, K. M. S. (2022) · International Conference of Advanced Technology in Electronic and Electrical Engineering (ICATEEE) · doi:10.1109/icateee57445.2022.10093712
“Model of a faulty PMSM The presence of the electrical and magnetic faults lead to asymmetry of the PMSM and produces harmonics in the stator-current spectrum [10], so the stator current quadratic and direct (id and iq) are expanded by a sinusoidal component of pulsation ωi = 2π.”
BackgroundFemia, A., Cagliari, G. A., Sala, G., Rizzoli, G., Gritli, Y., Tani, A., & Zarri, L. (2025) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped53223.2025.11154140
Arshad, M. H., Maraaba, L. S., Abido, M. A., & Zhao, Q. Z. (2026) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2026.3704523
Metadata
- Authors
- Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Ortega, J.A.
- Venue
- 2007 IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 2007
- Pages
- 1936-1941
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2136389802
- Cited by
- 63
- References
- 11
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 4
- FWCI
- 5.72
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Electronics Specialists Conference (PESC) (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, short circuit detection, winding faults, wavelet analysis, fault transients, condition monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.