Intrusion Detection System for IEC 60870-5-104 based SCADA networks
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Increased complexity and interconnectivity of Supervisory Control and Data Acquisition (SCADA) systems in Smart Grids potentially means greater susceptibility to malicious attackers. SCADA systems with legacy communication infrastructure have inherent cyber-security vulnerabilities as these systems were originally designed with little consideration of cyber threats. In order to improve cyber-security of SCADA networks, this paper presents a rule-based Intrusion Detection System (IDS) using a Deep Packet Inspection (DPI) method, which includes signature-based and model-based approaches tailored for SCADA systems. The proposed signature-based rules can accurately detect several known suspicious or malicious attacks. In addition, model-based detection is proposed as a complementary method to detect unknown attacks. Finally, proposed intrusion detection approaches for SCADA networks are implemented and verified via Snort rules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099234 · Cited by 259 · cited 3×
“Previous published works mainly focus on Modbus or DNP3 protocols, particularly [8]-[10].”
BackgroundMethod
Cited by
Cyber security of a power grid: State-of-the-art
Sun, C.-C., Hahn, A., & Liu, C.-C. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.12.020 · Cited by 481
A survey of cyber security management in industrial control systems
Knowles, W., Prince, D., Hutchison, D., Disso, J. F. P., & Jones, K. (2015) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2015.02.002 · Cited by 344
A Survey on SCADA Systems: Secure Protocols, Incidents, Threats and Tactics
Pliatsios, D., Sarigiannidis, P., Lagkas, T., & Sarigiannidis, A. G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2987688 · Cited by 320
“Yang et al. [135] proposed a rule-based IDS using a deep packet inspection method that includes signature-based and model-based detection approaches tailored to the IEC 60870 communication protocol.”
MethodAlotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Multi-level Anomaly Detection in Industrial Control Systems via Package Signatures and LSTM Networks
Feng, C., Li, T., & Chana, D. (2017) · 2017 47th Annual IEEE/IFIP International Conference on Dependable Systems and Networks (DSN) · doi:10.1109/dsn.2017.34 · Cited by 231
“The work presented in [19] provides an IDS specifically for the international standard IEC 60870-5 for ICS by using a Deep Packet Inspection technique, where signature-based rules are implemented by Snort to identify suspicious behaviours, with a complementary model-based mechanism for unknown…”
BackgroundMethodSecuring the Smart Grid: A Comprehensive Compilation of Intrusion Detection and Prevention Systems
Radoglou-Grammatikis, P. I., & Sarigiannidis, P. G. (2019) · IEEE Access · doi:10.1109/access.2019.2909807 · Cited by 226
Multidimensional Intrusion Detection System for IEC 61850-Based SCADA Networks
Yang, Y., Xu, H.-Q., Gao, L., Yuan, Y.-B., McLaughlin, K., & Sezer, S. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2603339 · Cited by 166
Self-citationTowards Understanding Man-In-The-Middle Attacks on IEC 60870-5-104 SCADA Networks
Maynard, P., McLaughlin, K., & Haberler, B. (2014) · 2nd International Symposium for ICS & SCADA Cyber Security Research 2014 · doi:10.14236/ewic/ics-csr2014.5 · Cited by 65
Self-citationA hypergraph based Kohonen map for detecting intrusions over cyber–physical systems traffic
Jagtap, S. S., V. S., S. S., & V., S. (2021) · Future Generation Computer Systems · doi:10.1016/j.future.2021.02.001 · Cited by 29
Kim, H., Kim, S., Jo, W., Kim, K.-H., & Shon, T. (2021) · IEEE Access · doi:10.1109/access.2021.3080081 · Cited by 14
A Distributed Edge FLISR Solution & Network Simulation Test Platform
Leniston, D., Ryan, D., Malone, C., & Dey, I. (2024) · arXiv · doi:10.48550/arxiv.2407.17497
“Communication with the DSOs SCADA system conforms to the IEC 60870-5-101/104 protocol, based on TCP/IP communications and enables basic control tasks between centralized control centers and connected assets, through connection from the RTU to a IEC 101 Master & IEC 104 Server [23].”
Method
Metadata
- Authors
- Yang, Y., McLaughlin, K., Littler, T., Sezer, S., Pranggono, B., & Wang, H. F.
- Venue
- 2013 IEEE Power & Energy Society General Meeting
- Publisher
- IEEE
- Published
- 2013
- Pages
- 1-5
- OpenAlex
- W1970856950
- Cited by
- 103
- References
- 1
- FWCI
- 9.60
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.