The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Multidimensional Intrusion Detection System for IEC 61850-Based SCADA Networks
Open accessAbstract
Emerging cybersecurity vulnerabilities in supervisory control and data acquisition (SCADA) systems are becoming urgent engineering issues for modern substations. This paper proposes a novel intrusion detection system (IDS) tailored for cybersecurity of IEC 61850 based substations. The proposed IDS integrates physical knowledge, protocol specifications, and logical behaviors to provide a comprehensive and effective solution that is able to mitigate various cyberattacks. The proposed approach comprises access control detection, protocol whitelisting, model-based detection, and multiparameter-based detection. This SCADA-specific IDS is implemented and validated using a comprehensive and realistic cyber-physical test-bed and data from a real 500 kV smart substation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099234 · Cited by 259
Exploiting the GOOSE protocol: A practical attack on cyber-infrastructure
Hoyos, J., Dehus, M., & Brown, T. X. (2012) · 2012 IEEE Globecom Workshops · doi:10.1109/glocomw.2012.6477809 · Cited by 137
Flow whitelisting in SCADA networks
Barbosa, R. R. R., Sadre, R., & Pras, A. (2013) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2013.08.003 · Cited by 90
Cited by
Ahmad, Z., Shahid Khan, A., Wai Shiang, C., Abdullah, J., & Ahmad, F. (2021) · Transactions on Emerging Telecommunications Technologies · doi:10.1002/ett.4150 · Cited by 1,288
Cyber security of a power grid: State-of-the-art
Sun, C.-C., Hahn, A., & Liu, C.-C. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.12.020 · Cited by 481
Alotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Architecture and security of SCADA systems: A review
Yadav, G., & Paul, K. (2021) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2021.100433 · Cited by 261
Girdhar, M., Hong, J., Lee, H., & Song, T.-J. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3122106 · Cited by 76
Metadata
- Authors
- Yang, Y., Xu, H.-Q., Gao, L., Yuan, Y.-B., McLaughlin, K., & Sezer, S.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-04
- Volume
- 32
- Issue
- 2
- Pages
- 1068-1078
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2515527499
- Cited by
- 166
- References
- 3
- FWCI
- 11.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multidimensional Intrusion Detection System for IEC 61850-Based SCADA Networks. https://app.cochat.ai/papers/10.1109/tpwrd.2016.2603339
- The paper
- Yang, Y., Xu, H.-Q., Gao, L., Yuan, Y.-B., McLaughlin, K., & Sezer, S. (2017). Multidimensional Intrusion Detection System for IEC 61850-Based SCADA Networks. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2016.2603339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.