The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Biologically Inspired Joint Stiffness Control
Abstract
Biological systems are able to perform movements in unpredictable environments more elegantly than traditionally engineered robotic systems. A current limitation of robotic systems is their inability to simultaneously and independently control both joint angle and joint stiffness without electromechanical feedback loops, which can reduce system stability. In this paper, we describe the development and physical implementation of a servo-actuated robotic joint that uses antagonistic, series-elastic actuation with novel nonlinear spring mechanisms. These mechanisms form a real-time mechanical feedback loop that provides the joint with angle and stiffness control through differential and common-mode actuation of the servos, respectively. This approach to joint control emulates the mechanics of antagonistic muscle groups used by animals, and we experimentally show that it is capable of independently controlling both joint angle and joint stiffness using a simple open-loop control algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152 · cited 1×
“In biology, joint compliance is a function of muscular cocontraction given that an increase in a muscle’s activation increases the number of parallel elastic elements used by the muscle, which raises the muscle’s stiffness [ 17 ], [18].”
BackgroundPratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Adaptive control of mechanical impedance by coactivation of antagonist muscles
Hogan, N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103644 · Cited by 1,041
Mechanical work in terrestrial locomotion: two basic mechanisms for minimizing energy expenditure
Cavagna, G. A., Heglund, N. C., & Taylor, C. R. (1977) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1977.233.5.r243 · Cited by 515
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D. J., & Pratt, G. A. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803231 · Cited by 409
Design of components for programmable passive impedance
Laurin-Kovitz, K. F., Colgate, J. E., & Carnes, S. D. R. (2002) · Proceedings. 1991 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1991.131824 · Cited by 191
Design and development of a new robot joint using a mechanical impedance adjuster
Morita, T., & Sugano, S. (2002) · Proceedings of 1995 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1995.525630 · Cited by 159
van der Linde, R. Q. (1999) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.781963 · Cited by 126
Kirsch, R. F., Boskov, D., & Rymer, W. Z. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.310091 · Cited by 120
Study of the antagonistic stiffness of parallel manipulators with actuation redundancy
Chakarov, D. (2004) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2003.12.001 · Cited by 119
Mechanics and stiffness limitations of a variable stiffness actuator for use in prosthetic limbs
English, C. E., & Russell, D. (1999) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(98)00026-3 · Cited by 106
Implementation of variable joint stiffness through antagonistic actuation using rolamite springs
English, C. E., & Russell, D. (1999) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(97)00103-1 · Cited by 85
Development of one-DOF robot arm equipped with mechanical impedance adjuster
Morita, T., & Sugano, S. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1995.525828 · Cited by 50
Cited by
Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D. (2009) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2009.933629 · Cited by 834
Albu-Schaffer, A., Eiberger, O., Grebenstein, M., Haddadin, S., Ott, C., Wimbock, T., Wolf, S., & Hirzinger, G. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927979 · Cited by 506
Variable Stiffness Actuators: Review on Design and Components
Wolf, S., Grioli, G., Eiberger, O., Friedl, W., Grebenstein, M., Hoppner, H., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M. G., et al. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2501019 · Cited by 459
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Metadata
- Authors
- Migliore, S. A., Brown, E. A., & DeWeerth, S. P.
- Venue
- Proceedings of the 2005 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2006-01-18
- Pages
- 4508-4513
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2108154420
- Cited by
- 291
- References
- 13
- FWCI
- 22.94
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.