Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor
The DOI matches its Crossref record.
Abstract
Respiratory rate is an essential parameter in the clinical monitoring of hospital patients. It can be measured in various ways, such as by recording chest movements, breathing flow or heart rate variations. Current sensor technology allows the development of new kinds of convenient and portable respiratory rate recorders, including smart shirts, which enable more efficient healthcare processes in hospitals. This study carried out respiratory rate measurements using a sensor belt with a high-resolution accelerometer (capacitive MEMS) and an EMFit (electret film) pressure sensor. Results obtained from tests on 10 subjects showed that both sensors are feasible for respiratory rate measurement; the reliability of the MEMS was 90%, while that of the EMFit was 90- 100%. In addition, the results showed that the location of the sensor module on the chest is important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Human Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data
Bates, A., Ling, M. J., Mann, J., & Arvind, D. K. (2010) · 2010 International Conference on Body Sensor Networks · doi:10.1109/bsn.2010.50 · Cited by 163
“worn on the torso can measure inclination changes due to rotation of the chest wall during breathing, and that this can be used to obtain a respiratory rate [7]–[10].”
MethodPandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
“The studies that have investigated the respiratory aspects of SCG measurements have primarily focused on the ultra-low frequency ( 1 Hz) fluctuations of the signal caused by the movement of the chest wall (Morillo et al 2010, Reinvuo et al 2006).”
BackgroundFekr, A. R., Radecka, K., & Zilic, Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2445783 · Cited by 61
“In [20], an accelerometer and pressure sensors are worn on the body to obtain the respiratory rate.”
Metadata
- Authors
- Reinvuo, T., Hannula, M., Sorvoja, H., Alasaarela, E., & Myllyla, R.
- Venue
- Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006.
- Publisher
- IEEE
- Published
- 2006-05-25
- Pages
- 192-195
- OpenAlex
- W2117749765
- Cited by
- 105
- References
- 0
- FWCI
- 6.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor. https://app.cochat.ai/papers/10.1109/sas.2006.1634270
- The paper
- Reinvuo, T., Hannula, M., Sorvoja, H., Alasaarela, E., & Myllyla, R. (2006). Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor. Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006. https://doi.org/10.1109/sas.2006.1634270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.