A batch-fabricated silicon accelerometer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An extremely small batch-fabricatable accelerometer has been developed using silicon IC technology. The device, 3 mm long and weighing 0.02 g, is a simple cantilevered beam and mass structure sealed into a silicon and glass package. The fabrication of the accelerometer is described, and the theory behind its operation developed. Experimental results on sensitivity, frequency response, and linearity are presented and found to agree with theory. The accelerometer is capable of measuring accelerations from 0.001 to 50 g over a 100-Hz bandwidth, while readily implemented geometry changes allow these performance characteristics to be varied over a wide range to meet the needs of differing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of Vibration with Applications
Thomson, W. T. (2018) · CRC Press eBooks · doi:10.1201/9780203718841 · Cited by 989
Field Assisted Glass-Metal Sealing
Wallis, G., & Pomerantz, D. I. (1969) · Journal of Applied Physics · doi:10.1063/1.1657121 · Cited by 746
Cited by
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Micromachined inertial sensors
Yazdi, N., Ayazi, F., & Najafi, K. (1998) · Proceedings of the IEEE · doi:10.1109/5.704269 · Cited by 1,823
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“fabricated MEMS accelerometers were reported in 1979 [11].”
MethodReview: Semiconductor Piezoresistance for Microsystems
Barlian, A. A., Park, W.-T., Mallon, J. R., Rastegar, A. J., & Pruitt, B. L. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2013612 · Cited by 949
Strategies for increasing the operating frequency range of vibration energy harvesters: a review
Zhu, D., Tudor, M. J., & Beeby, S. P. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/2/022001 · Cited by 664
Theory, technology and applications of piezoresistive sensors: A review
Fiorillo, A. S., Critello, C. D., & Pullano, S. A. (2018) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2018.07.006 · Cited by 591
Esashi, M. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/7/073001 · Cited by 358
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Zhu, D., & Beeby, S. (2011) · Energy Harvesting Systems · doi:10.1007/978-1-4419-7566-9_1 · Cited by 62
Metadata
- Authors
- Roylance, L. M., & Angell, J. B.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1979-12
- Volume
- 26
- Issue
- 12
- Pages
- 1911-1917
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W1987780641
- Cited by
- 512
- References
- 2
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.