A tantalum-on-sapphire microelectrode array
The DOI matches its Crossref record.
Abstract
The design and fabrication are described of a new microelectrode array for the production of localized electrical excitation in nerve fibers, in particular in the auditory nerve. The sapphire substrate was chosen for its electrical (insulating) and mechanical properties, tantalum was chosen as the conductor metal because of its self-passivating characteristics, and platinum as the stimulation electrode material because of its resistance to electrolysis. Experimental measurements are presented to show the effectiveness of Ta2O5as an insulator in biphasic charge delivery systems, and the effectiveness of conformal dielectric overcoating of the Ta2O5in reducing capacitive signal leakage is demonstrated. The electrochemical properties of the platinum-electrolyte interface are shown to provide a satisfactory model on which to estimate the charge delivery capabilities of the electrodes. Finally, the sequence of process-compatible steps for fabricating the microelectrode array, from the first tantalum deposition to the final overcoating are detailed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
Metadata
- Authors
- May, G. A., Shamma, S. A., & White, R. L.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1979-12
- Volume
- 26
- Issue
- 12
- Pages
- 1932-1939
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2013979839
- Cited by
- 41
- References
- 0
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A tantalum-on-sapphire microelectrode array. https://app.cochat.ai/papers/10.1109/t-ed.1979.19798
- The paper
- May, G. A., Shamma, S. A., & White, R. L. (1979). A tantalum-on-sapphire microelectrode array. IEEE Transactions on Electron Devices. https://doi.org/10.1109/t-ed.1979.19798
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.