Speckle in ultrasound B-mode scans
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Ultrasound images obtained with a simple linear or sector scan show a granular appearance, called "speckle." This speckle is analyzed. The reduction in speckle that can be obtained with a compound scan with maximum amplitude writing is computed. The reduction in speckle is almost as large as can be obtained with averaging. It depends on the number of independent amplitude values that are measured. The condition for the independence of two amplitude values is derived, and thus a limit is given for the possible reduction in speckle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Theory of Random Signals and Noise
Davenport, W. B., & Root, W. L. (1987) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544143 · Cited by 1,452
Laser Speckle and Related Phenomena
(1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1 · Cited by 1,330
An Introduction to the Theory of Random Signals and Noise
Davenport, W. B., Root, W. L., & Weiss, G. (1958) · Physics Today · doi:10.1063/1.3062606 · Cited by 1,277
Statistical Properties of Laser Speckle Patterns
Goodman, J. W. (1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1_2 · Cited by 1,249
An Introduction to Statistical Communication Theory
Middleton, D. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544112.part1 · Cited by 1,127
An introduction to statistical communication theory
Siebert, W. M. (1961) · Journal of the Franklin Institute · doi:10.1016/0016-0032(61)90153-3 · Cited by 703
Statistical properties of laser speckle patterns
Goodman, J. W. (1975) · Topics in Applied Physics · doi:10.1007/bfb0111436 · Cited by 575
Cited by
Statistics of Speckle in Ultrasound B-Scans
Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1983.31404 · Cited by 1,398
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
“[174], [175]).”
BackgroundSasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
A Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432
Abd-Elmoniem, K. Z., Youssef, A.-B. M., & Kadah, Y. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1028423 · Cited by 403
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
Acoustic speckle: Theory and experimental analysis
Abbott, J. (1979) · Ultrasonic Imaging · doi:10.1016/0161-7346(79)90024-5 · Cited by 269
Kadah, Y. M., Farag, A. A., Zurada, J. M., Badawi, A. M., & Youssef, A.-B. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511750 · Cited by 265
Beam Steering with Linear Arrays
Von Ramm, O. T., & Smith, S. W. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325149 · Cited by 262
Ultrasonic B-scanning: a computer simulation
Bamber, J. C., & Dickinson, R. J. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/3/006 · Cited by 223
Destrempes, F., & Cloutier, G. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.04.001 · Cited by 196
“The accumulation of the random scatterings can be modeled by a random walk of component phasors (Burckhardt 1978; Wagner et al. 1983).”
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Burckhardt, C. B.
- Venue
- IEEE Transactions on Sonics and Ultrasonics
- Published
- 1978-01
- Volume
- 25
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0018-9537 (ISSN-L)
- OpenAlex
- W2130622335
- Cited by
- 1,066
- References
- 7
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.