Broadband Tissue Mimicking Phantoms and a Patch Resonator for Evaluating Noninvasive Monitoring of Blood Glucose Levels
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Tissue mimicking phantoms (TMPs) replicating the dielectric properties of wet skin, fat, blood, and muscle tissues for the 0.3 to 20 GHz frequency range are presented in this paper. The TMPs reflect the dielectric properties with maximum deviations of 7.7 units and 3.9 S/m for relative dielectric constant and conductivity, respectively, for the whole band. The dielectric properties of the blood mimicking material are further investigated by adding realistic glucose amounts and a Cole-Cole model used to compare the behavior with respect to changing glucose levels. In addition, a patch resonator was fabricated and tested with the four-layered physical phantom developed in house. It was observed that the input impedance of the resonator is sensitive to the changes in the dielectric properties and, hence, to the realistic glucose level changes in the blood layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 7×
“45 GHz), also given in Table III [19], [20].”
BackgroundMethodResultInfluentialGabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156 · cited 1×
“45 GHz), also given in Table III [19], [20].”
BackgroundLazebnik, M., Popovic, D., McCartney, L., Watkins, C. B., Lindstrom, M. J., Harter, J. M., Sewall, S., Ogilvie, T., Magliocco, A. M., Breslin, T. M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/20/002 · Cited by 1,402
Karacolak, T., Hood, A. Z., & Topsakal, E. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.919373 · Cited by 633 · cited 1×
“Radio frequency (RF) techniques in the literature are mostly focused on telemetry and BGL sensing is usually performed with a chemical sensor [2]–[4].”
BackgroundTissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
Lazebnik, M., Madsen, E. L., Frank, G. R., & Hagness, S. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/18/001 · Cited by 418
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266 · cited 1×
“Radio frequency (RF) techniques in the literature are mostly focused on telemetry and BGL sensing is usually performed with a chemical sensor [2]–[4].”
BackgroundLazebnik, M., Converse, M. C., Booske, J. H., & Hagness, S. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/022 · Cited by 194 · cited 1×
“It has been also shown [23] that the single pole Cole-Cole fitting is more efficient than two pole ColeCole fitting, because the number of parameters is smaller and the single pole fitting represents the measured data just as well as two pole fitting.”
BackgroundA microwave frequency sensor for non-invasive blood-glucose measurement
Jean, B. R., Green, E. C., & McClung, M. J. (2008) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2008.4472932 · Cited by 149 · cited 1×
“One of the studies published in this area is given in [5] and [6]; in this work, a two-port spiral resonator is presented.”
BackgroundDielectric spectroscopy study of specific glucose influence on human erythrocyte membranes
Hayashi, Y., Livshits, L., Caduff, A., & Feldman, Y. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/4/307 · Cited by 142 · cited 3×
“However, the dielectric property data given to the simulation software was derived from [8].”
BackgroundMethodInfluential
Cited by
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“The permittivity and conductivity of the tissue depend on the frequency of the applied EM signal and the glucose concentration [1,172,173].”
BackgroundRadio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 192
“When compared to the conclusions drawn in [26], where the change in relative permittivity was expected to be 1 unit for glucose levels from 0 mg/dL to 216 mg/dL, these changes in permittivity values are very large.”
BackgroundMethodResultInfluentialSelf-citation3D‐Printed Hydrogel‐Filled Microneedle Arrays
Barnum, L., Quint, J., Derakhshandeh, H., Samandari, M., Aghabaglou, F., Farzin, A., Abbasi, L., Bencherif, S., Memic, A., Mostafalu, P., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001922 · Cited by 89
Metadata
- Authors
- Yilmaz, T., Foster, R., & Hao, Y.
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2014-06
- Volume
- 62
- Issue
- 6
- Pages
- 3064-3075
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W1990505168
- Cited by
- 168
- References
- 17
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.