Multichannel Reflective PPG Earpiece Sensor With Passive Motion Cancellation
Abstract
This paper addresses the design considerations of a novel earpiece photoplethymograph (PPG) sensor and its in-situ evaluation results. The device is encapsulated with multiple LEDs and photodiodes based on a reflective PPG design. A compact and low power circuitry was developed for signal control and conditioning. PPG signals with an averaged ac/dc ratio of 0.001-0.01 and 10% relative strength (compared to finger-based approach) were recorded from the superior and posterior auricular skins. The integrity of PPG signal and accuracy of heart rate detection were evaluated and the results showed that with adequate optical shielding and the proposed passive motion cancellation, the device was able to reliably detect heart rate both during rest and moderate exercise. The proposed sensor design is low power, easy to wear compared to conventional earlobe PPG devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This method was found to be effective in shielding from noise due to ambient light, as the DC level of the PPG signal was considerably low (measured to be less than 2 nA) when the LEDs were switched off.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [200]
Citations
Cites
Yang, G. (2006) · Springer eBooks · doi:10.1007/1-84628-484-8 · Cited by 569
Drake, R. L., Vogl, A. W., & Mitchell, A. W. (2004) · Cited by 512
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
(1997) · Institute of Physics eBooks · doi:10.1887/0750304677 · Cited by 455
(1997) · Series in medical physics and biomedical engineering · doi:10.1201/9781420050790 · Cited by 364
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Obituary: Yukio Mano (1943–2004)
Ikoma, K. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-1 · Cited by 173
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Y. S., Poon, C. C. Y., & Zhang, Y. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-3 · Cited by 157
Pulse oximetry in the oesophagus
Kyriacou, P. A. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/r01 · Cited by 91
Design of filter to reject motion artifact of pulse oximetry
Lee, J., Jung, W.-G., Kang, I., Kim, Y., & Lee, G.-K. (2003) · Computer Standards & Interfaces · doi:10.1016/s0920-5489(03)00077-1 · Cited by 91
Optical noninvasive monitoring of skin blood pulsations
Spīgulis, J. (2005) · Applied Optics · doi:10.1364/ao.44.001850 · Cited by 75
Mendelson, Y., & Pujary, C. J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280775 · Cited by 74
Multilayer Modeling of Reflectance Pulse Oximetry
Reuss, J. L. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840188 · Cited by 72
Artifact reduction in photoplethysmography
Hayes, M., & Smith, P. R. (1998) · Applied Optics · doi:10.1364/ao.37.007437 · Cited by 71
Wong, A., Pun, K.-P., Zhang, Y.-T., & Hung, K. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.857767 · Cited by 63
Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation
Renevey, P., Vetter, R., Krauss, J., Celka, P., & Depeursinge, Y. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1017437 · Cited by 63
Gibbs, P., & Asada, H. H. (2005) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2005.1470193 · Cited by 62
Wearable Multisensor Heart Rate Monitor
Grajales, L., & Nicolaescu, I. V. (2006) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2006.58 · Cited by 46
Exercise and Sports Cardiology
Thompson, P. D., & Fernández, A. B. (2016) · WORLD SCIENTIFIC (EUROPE) eBooks · doi:10.1142/q0045-vol1 · Cited by 39
Processing of Pulse Oximeter Data Using Discrete Wavelet Analysis
Lee, S., Ibey, B. L., Xü, W., Wilson, M. A., Ericson, M. N., & Coté, G. L. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847538 · Cited by 27
Signal quality and power consumption of a new prototype reflectance pulse oximeter sensor
Branche, P. C., & Mendelson, Y. (2005) · Proceedings of the IEEE Annual Northeast Bioengineering Conference · doi:10.1109/nebc.2005.1431917 · Cited by 18
Active Motion Artifact Reduction for Wearable Sensors Using Laguerre Expansion and Signal Separation
Wood, L. B., & Asada, H. H. (2005) · doi:10.1109/iembs.2005.1617251 · Cited by 17
The Design And Clinical Use Of A Reflective Brachial Photoplethysmograph
Maguire, M. F., & Ward, T. E. (2002) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 6
Nogawa, M., Tanaka, S., Shibata, M., & Yamakoshi, K.-I. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403649 · Cited by 4
Exercise and Sports Cardiology
Thompson, P. D., & Fernández, A. B. (2016) · WORLD SCIENTIFIC (EUROPE) eBooks · doi:10.1142/q0045 · Cited by 1
Research works printed but not linked: 1
- Celka, Motion resistant earphone located infrared based heart rate measurement device, 582
Cited by
Sorted by citations
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“01 and 10% relative strength compared with the finger-based approach were recorded from superior and posterior auricular skin [25].”
BackgroundResultUnobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G., Zhao, N., & Zhang, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 725
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Metadata
- Authors
- Wang, L., Lo, B. P., & Yang, G.-Z.
- Affiliations
- Imperial College London (GB)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2007-12
- Volume
- 1
- Issue
- 4
- Pages
- 235-241
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2109125512
- Cited by
- 114
- References
- 27
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 6 · 2019: 11 · 2018: 6 · 2017: 5 · 2016: 5 · 2015: 9 · 2014: 9 · 2013: 4 · 2012: 4
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/E044298/1, EP/C547586/1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- photoplethysmography, heartbeat detection, optical shielding, exercise monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review