CoChat
Cited by 202

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction

Gosselin, Benoit, Ayoub, Amer E., Roy, Jean-FranÇois, Sawan, Mohamad, Lepore, Franco, Chaudhuri, Avi, Guitton, Daniel · 2009 · IEEE Transactions on Biomedical Circuits and Systems

Abstract

We present a multichip structure assembled with a medical-grade stainless-steel microelectrode array intended for neural recordings from multiple channels. The design features a mixed-signal integrated circuit (IC) that handles conditioning, digitization, and time-division multiplexing of neural signals, and a digital IC that provides control, bandwidth reduction, and data communications for telemetry toward a remote host. Bandwidth reduction is achieved through action potential detection and complete capture of waveforms by means of onchip data buffering. The adopted architecture uses high parallelism and low-power building blocks for safety and long-term implantability. Both ICs are fabricated in a CMOS 0.18-mum process and are subsequently mounted on the base of the microelectrode array. The chips are stacked according to a vertical integration approach for better compactness. The presented device integrates 16 channels, and is scalable to hundreds of recording channels. Its performance was validated on a testbench with synthetic neural signals. The proposed interface presents a power consumption of 138 muW per channel, a size of 2.30 mm(2), and achieves a bandwidth reduction factor of up to 48 with typical recordings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2009.2013718

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 202

Metadata

Authors
Gosselin, B., Ayoub, A. E., Roy, J.-F., Sawan, M., Lepore, F., Chaudhuri, A., & Guitton, D.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2009-06
Volume
3
Issue
3
Pages
129-141
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2106594227
Cited by
202
References
8
FWCI
7.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction. https://app.cochat.ai/papers/10.1109/tbcas.2009.2013718
The paper
Gosselin, B., Ayoub, A. E., Roy, J.-F., Sawan, M., Lepore, F., Chaudhuri, A., & Guitton, D. (2009). A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2009.2013718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.