An Integrated System for Multichannel Neuronal Recording With Spike/LFP Separation, Integrated A/D Conversion and Threshold Detection
Abstract
A mixed-signal front-end processor for multichannel neuronal recording is described. It receives 12 differential-input channels of implanted recording electrodes. A programmable cutoff High Pass Filter (HPF) blocks dc and low-frequency input drift at about 1 Hz. The signals are band-split at about 200 Hz to low-frequency Local Field Potential (LFP) and high-frequency spike data (SPK), which is band limited by a programmable-cutoff LPF, in a range of 8-13 kHz. Amplifier offsets are compensated by 5-bit calibration digital-to-analog converters (DACs). The SPK and LFP channels provide variable amplification rates of up to 5000 and 500, respectively. The analog signals are converted into 10-bit digital form, and streamed out over a serial digital bus at up to 8 Mbps. A threshold filter suppresses inactive portions of the signal and emits only spike segments of programmable length. A prototype has been fabricated on a 0.35-microm CMOS process and tested successfully, demonstrating a 3-microV noise level. Special interface system incorporating an embedded CPU core in a programmable logic device accompanied by real-time software has been developed to allow connectivity to a computer host.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neural amplifier ICs have been created that capture both action potentials and local field potentials, with separate filtering, amplification and output for each signal type.
“CNS amplifiers have also been developed that can acquire both types of signals, separately filtering, amplifying and outputting each signal type [46, 86, 100].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [100]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Dynamics of ongoing activity: explanation of the large variability in evoked cortical responses
Arieli, A., Sterkin, A., Grinvald, A., & Aertsen, A. (1996) · Science · doi:10.1126/science.273.5283.1868 · Cited by 1,660 · see citing works
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372 · see citing works
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 696 · see citing works
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640 · see citing works
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577 · see citing works
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 560 · see citing works
Donoghue, J. P., Sanes, J. N., Hatsopoulos, N. G., & Gaál, G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.1.159 · Cited by 538 · see citing works
Inference of hand movements from local field potentials in monkey motor cortex
Mehring, C., Rickert, J., Vaadia, E., de Oliveira, S. C., Aertsen, A., & Rotter, S. (2003) · Nature Neuroscience · doi:10.1038/nn1158 · Cited by 435 · see citing works
Continuous-Time Active Filter Design
Deliyannis, T., Sun, Y., & Fidler, J. (2010) · CRC Press eBooks · doi:10.1201/9781439821879 · Cited by 292 · see citing works
Continuous-time active filter design
(1999) · Choice Reviews Online · doi:10.5860/choice.36-5712 · Cited by 272 · see citing works
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245 · see citing works
Single-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214 · see citing works
Methods for neuronal recording in conscious animals
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90035-7 · Cited by 184 · see citing works
A 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180 · see citing works
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173 · see citing works
Cell based biosensors using microelectrodes
Borkholder, D. A. (1998) · Cited by 149 · see citing works
A low-power integrated circuit for adaptive detection of action potentials in noisy signals
Harrison, R. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280856 · Cited by 138 · see citing works
Power feasibility of implantable digital spike sorting circuits for neural prosthetic systems
Zumsteg, Z. S., Kemere, C. T., O’Driscoll, S., Santhanam, G., Ahmed, R. E., Shenoy, K. V., & Meng, T. H. Y. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.854307 · Cited by 138 · see citing works
A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications
Patterson, W. R., Song, Y., Bull, C. W., Ozden, I., Deangelis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. P., & Connors, B. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831521 · Cited by 100 · see citing works
A low-power CMOS neural amplifier with amplitude measurements for spike sorting
Horiuchi, T. K., Swindell, T., Sander, D., & Abshier, P. (2004) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2004.1328932 · Cited by 92 · see citing works
Two multichannel integrated circuits for neural recording and signal processing
Iyad Obeid, A., Morizio, J., Moxon, K. A., Nicolelis, M. A. L., & Wolf, P. D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.807643 · Cited by 85 · see citing works
A fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H., Gulari, A. N., & Wise, K. D. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196783 · Cited by 56 · see citing works
Low?Power Architectures for Spike Sorting
Zviagintsev, A., Perelman, Y., & Ginosar, R. (2005) · doi:10.1109/cne.2005.1419579 · Cited by 48 · see citing works
Self-citationConnecting brains with machines: the neural control of 2D cursor movement
Black, M. J., Bienenstock, E., Donoghue, J. P., et al. (2004) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196893 · Cited by 32 · see citing works
Analog frontend for multichannel neuronal recording system with spike and LFP separation
Perelman, Y., & Ginosar, R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.09.017 · Cited by 30 · see citing works
Self-citationA bio-amplifier with pulse output
Chen, D., Harris, J. G., & Príncipe, J. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404136 · Cited by 23 · see citing works
A low-power inverted ladder D/a converter
Perelman, Y., & Ginosar, R. (2006) · IEEE Transactions on Circuits and Systems II Analog and Digital Signal Processing · doi:10.1109/tcsii.2006.875313 · Cited by 13 · see citing works
Self-citationPower feasibility of implantable digital spike-sorting circuits for neural prosthetic systems
Zumsteg, Z. S., Ahmed, R. E., Santhanam, G., et al. (2005) · doi:10.1109/iembs.2004.1404181 · Cited by 12 · see citing works
A Low-Power Spike Detection and Alignment Algorithm
Zviagintsev, A., Perelman, Y., & Ginosar, R. (2005) · doi:10.1109/cne.2005.1419621 · Cited by 6 · see citing works
Self-citationInterpretation of Natural Language Database Queries Using Optimization Methods
Leigh, W. E., & Evans, J. A. (1986) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1986.289280 · Cited by 5 · see citing works
A Systems Approach for Real-Time Data Compression in Advanced Brain-Machine Interfaces
Oweiss, K. G., Thomson, K. E., & Anderson, D. J. (2005) · doi:10.1109/cne.2005.1419553 · Cited by 5 · see citing works
16-channel neural pre-conditioning device
Morizio, J., Won, D. S., Obeid, I., et al. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196767 · Cited by 5 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [3][3] A. B. Schwarz, 'Cortial neural prosthetics,' Annual review of Neuroscience , vol. 27, pp. 487-507, 2004. -
Cited by
Sorted by citations
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441 · see citing works
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · see citing works
A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146 · see citing works
A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145 · see citing works
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138 · see citing works
Rodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103 · see citing works
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66 · see citing works
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45 · see citing works
A Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23 · see citing works
- Authors
- Perelman, Y., & Ginosar, R.
- Affiliations
- Technion – Israel Institute of Technology (IL)
- ORCID
- Perelman, Yevgeny
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-01
- Volume
- 54
- Issue
- 1
- Pages
- 130-137
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2165280873
- Cited by
- 116
- References
- 33
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 4 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 6 · 2015: 8 · 2014: 9 · 2013: 7 · 2012: 7
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Technion-Israel Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- spike detection, local field potentials, high-pass filter, band splitting, threshold detection, implanted electrodes, CMOS integrated circuit, real-time data acquisition
- MeSH terms
- Action Potentials, Amplifiers, Electronic, Analog-Digital Conversion, Animals, Cerebral Cortex, Differential Threshold, Electroencephalography, Equipment Design, Neurons, Signal Processing, Computer-Assisted, Systems Integration, Equipment Failure Analysis, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review