Compressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Abstract
Compressed sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist processing of sparse signals such as electrocardiogram (ECG) and electromyogram (EMG) biosignals. Consequently, it can be applied to biosignal acquisition systems to reduce the data rate to realize ultra-low-power performance. CS is compared to conventional and adaptive sampling techniques and several system-level design considerations are presented for CS acquisition systems including sparsity and compression limits, thresholding techniques, encoder bit-precision requirements, and signal recovery algorithms. Simulation studies show that compression factors greater than 16X are achievable for ECG and EMG signals with signal-to-quantization noise ratios greater than 60 dB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,653
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Atomic Decomposition by Basis Pursuit
Chen, S. S., Donoho, D. L., & Saunders, M. A. (1998) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827596304010 · Cited by 6,845
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candes, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,839
CoSaMP: Iterative signal recovery from incomplete and inaccurate samples
Needell, D., & Tropp, J. A. (2009) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2008.07.002 · Cited by 4,326
The Detection of Defective Members of Large Populations
Dorfman, R. (1943) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177731363 · Cited by 1,626
Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-6 · Cited by 1,013
Normalized Iterative Hard Thresholding: Guaranteed Stability and Performance
Blumensath, T., & Davies, M. E. (2010) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2010.2042411 · Cited by 485
Xampling: analog to digital at sub-Nyquist rates
Mishali, M., Eldar, Y. C., Dounaevsky, O., & Shoshan, E. (2011) · IET Circuits, Devices & Systems · doi:10.1049/iet-cds.2010.0147 · Cited by 427
Theory and Implementation of an Analog-to-Information Converter using Random Demodulation
Laska, J. N., Kirolos, S., Duarte, M. F., Ragheb, T. S., Baraniuk, R. G., & Massoud, Y. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378360 · Cited by 412
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
A Sub-100 $\mu$W MICS/ISM Band Transmitter Based on Injection-Locking and Frequency Multiplication
Pandey, J., & Otis, B. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2118030 · Cited by 161
A low-power integrated circuit for adaptive detection of action potentials in noisy signals
Harrison, R. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280856 · Cited by 138
On the Difference Between Orthogonal Matching Pursuit and Orthogonal Least Squares
Blumensath, T., & Davies, M. E. (2007) · ePrints Soton (University of Southampton) · Cited by 93
Reconciling Compressive Sampling Systems for Spectrally Sparse Continuous-Time Signals
Lexa, M., Davies, M. E., & Thompson, J. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2169408 · Cited by 79
A signal-agnostic compressed sensing acquisition system for wireless and implantable sensors
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2010) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2010.5617383 · Cited by 79
Input-Feature Correlated Asynchronous Analog to Information Converter for ECG Monitoring
Agarwal, R., & Sonkusale, S. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2116787 · Cited by 53
An Adaptive Sampling System for Sensor Nodes in Body Area Networks
Rieger, R., & Taylor, J. T. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008648 · Cited by 39
Compressed sensing of ECG bio-signals using one-bit measurement matrices
Allstot, E. G., Chen, A. Y., Dixon, A. M. R., Gangopadhyay, D., Mitsuda, H., & Allstot, D. J. (2011) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2011.5981293 · Cited by 16
Self-citationA low-power asynchronous ECG acquisition system in CMOS technology
Hwang, S., Trakimas, M., & Sonkusale, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626292 · Cited by 11
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
A Survey on Wireless Body Area Networks: Technologies and Design Challenges
Cavallari, R., Martelli, F., Rosini, R., Buratti, C., & Verdone, R. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2014.012214.00007 · Cited by 710
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2226175 · Cited by 340
Continuous patient monitoring with a patient centric agent: a block architecture
Uddin, M. A., Stranieri, A., Gondal, I., & Balasubramanian, V. (2018) · IEEE Access · doi:10.1109/access.2018.2846779 · Cited by 264
Energy-Efficient Multi-Mode Compressed Sensing System for Implantable Neural Recordings
Suo, Y., Zhang, J., Xiong, T., Chin, P. S., Etienne-Cummings, R., & Tran, T. D. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359180 · Cited by 47
Metadata
- Authors
- Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-04
- Volume
- 6
- Issue
- 2
- Pages
- 156-166
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2134207998
- Cited by
- 311
- References
- 25
- FWCI
- 30.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.