CoChat

Flexible Charge Balanced Stimulator With 5.6 fC Accuracy for 140 nC Injections

Nag, S., Xiaofeng Jia, Thakor, N., Sharma, D. · 2013 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 38

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Electrical stimulations of neuronal structures must ensure net injected charges to be zero for biological safety and voltage compliance reasons. We present a novel architecture of general purpose biphasic constant current stimulator that exhibits less than 5.6 fC error while injecting 140 nC charges using 1.4 mA currents. The floating current sources and conveyor switch based system can operate in monopolar or bipolar modes. Anodic-first or cathodic-first pulses with optional inter-phase delays have been demonstrated with zero quiescent current requirements at the analog front-end. The architecture eliminates blocking capacitors, electrode shorting and complex feedbacks. Bench-top and in-vivo measurement results have been presented with emulated electrode impedances (resistor-capacitor network), Ag-AgCl electrodes in saline and in-vivo (acute) peripheral nerve stimulations in anesthetized rats.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2012.2205574

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 38

Metadata

Authors
Nag, S., Jia, X., Thakor, N., & Sharma, D.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2013-06
Volume
7
Issue
3
Pages
266-275
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2038563595
Cited by
38
References
3
FWCI
1.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.