The DOI matches its Crossref record; 30 of the 32 references it cites were found in a registry or an index.
A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Open accessAbstract
Tongue drive system (TDS) is a tongue-operated, minimally invasive, unobtrusive, and wireless assistive technology (AT) that infers users' intentions by detecting their voluntary tongue motion and translating them into user-defined commands. Here we present the new intraoral version of the TDS (iTDS), which has been implemented in the form of a dental retainer. The iTDS system-on-a-chip (SoC) features a configurable analog front-end (AFE) that reads the magnetic field variations inside the mouth from four 3-axial magnetoresistive sensors located at four corners of the iTDS printed circuit board (PCB). A dual-band transmitter (Tx) on the same chip operates at 27 and 432 MHz in the Industrial/Scientific/Medical (ISM) band to allow users to switch in the presence of external interference. The Tx streams the digitized samples to a custom-designed TDS universal interface, built from commercial off-the-shelf (COTS) components, which delivers the iTDS data to other devices such as smartphones, personal computers (PC), and powered wheelchairs (PWC). Another key block on the iTDS SoC is the power management integrated circuit (PMIC), which provides individually regulated and duty-cycled 1.8 V supplies for sensors, AFE, Tx, and digital control blocks. The PMIC also charges a 50 mAh Li-ion battery with constant current up to 4.2 V, and recovers data and clock to update its configuration register through a 13.56 MHz inductive link. The iTDS SoC has been implemented in a 0.5-μm standard CMOS process and consumes 3.7 mW on average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“2227962 leveraging advancements in neurosciences, microelectronics, wireless communications, and computing [2]–[8].”
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 2×
“TABLE I FREQUENCY-DEPENDENT ATTENUATION CHARACTERISTICS OF TISSUE [33]”
Calabrese, V. P. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490230111048 · Cited by 2,501
Field and wave electromagnetics
Cheng, D. K. (1983) · Cited by 2,199
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Assistive Technologies: Principles and Practice
Cook, A. M., & Polgar, J. M. (1995) · Cited by 992
System for assisted mobility using eye movements based on electrooculography
Barea, R., Boquete, L., Mazo, M., & Lopez, E. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806829 · Cited by 486
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321 · cited 2×
“5 s before moving to another command position [13].”
Self-citationLee, H.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2010.2103172 · Cited by 227 · cited 2×
“This circuit also generates a short pulse for every detected bit “1” and applies it to the load-shift-keying (LSK) mechanism of the active rectifier [39].”
Self-citationA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazicioglu, R. F., Grundlehner, B., Harpe, P., Makinwa, K. A. A., & Van Hoof, C. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221
Research works printed but not linked: 8
- 2000, System and method to determine the location and orientation of an indwelling medical device
- rai, 2009, A 500 <formula formulatype="inline"><tex Notation="TeX">$\mu{\rm W}$</tex></formula> neural tag with 2 <formula formulatype="inline"><tex Notation="TeX">$\mu{\rm Vrms}$</tex></formula> AFE and frequency-multiplying MICS/ISM FSK transmitter, Proc IEEE ISSCC Dig Tech Papers
- 10.1109/TITB.2011.2158608 · DOI
- caruso, 0, A new perspective on magnetic field sensing, Honeywell Applications Note
- vieira, 0, Magnetoresistive Sensors for a Magnetometer
- 0, Origin Instrument Sip/Puff Switch
- capps, 2001, Near field or far field?, EDN Mag, 95
- giraldi, 1997, Independence day: Tongue-touch controls give Ben a more satisfying self-sufficient lifestyle, Teamrehab Report Mag
Cited by
Lee, Y., Howe, C., Mishra, S., Lee, D. S., Mahmood, M., Piper, M., Kim, Y., Tieu, K., Byun, H.-S., Coffey, J. P., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719573115 · Cited by 183
“Consequently, such devices add excessive mechanical and thermal loading and discomfort to a user, particularly considering that the oral mucosa (19, 20) is one of the most sensitive tissues in the body.”
BackgroundThe Tongue Enables Computer and Wheelchair Control for People with Spinal Cord Injury
Kim, J., Park, H., Bruce, J. A., Sutton, E., Rowles, D. M., Pucci, D., Holbrook, J. S., Minocha, J., Nardone, B., West, D. P., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006296 · Cited by 141
“In comparison to previous studies with a similar setup for centerout tapping (table S3), the throughput of able-bodied participants using a mouse was slightly higher than reported here (18, 53), but in the same range considering the SD (3.”
MethodResultSelf-citationAdaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review
Bocan, K. N., & Sejdić, E. (2016) · Sensors · doi:10.3390/s16030393 · Cited by 141
“Insensitive systems are designed for consistent operation over a range of environmental parameters, without the use of tuning components [35,52].”
BackgroundA 0.13- $\mu\text{m}$ CMOS SoC for Simultaneous Multichannel Optogenetics and Neural Recording
Gagnon-Turcotte, G., Khiarak, M. N., Éthier, C., Koninck, Y. D., & Gosselin, B. J. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2865474 · Cited by 54
“LDO for the MCU and the wireless transceiver; 4) a small (5 × 5 mm2 micro-ball grid array (BGA) package), low-power MSP430F5328 MCU from Texas Instruments, USA, an MCU family used in many low-power biomedical applications [35]–[37]; 5) the implantable module holding the microelectrodes, the LEDs, and the optical fiber…”
Self-citationA Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 54
“A sophisticated power scheduling scheme is often used in medical devices as exemplified in [59] were a duty cycling is applied to the higher power consumption circuits.”
Self-citationA Multimodal Adaptive Wireless Control Interface for People With Upper-Body Disabilities
Fall, C. L., Quevillon, F., Blouin, M., Latour, S., Campeau‐Lecours, A., Gosselin, C., & Gosselin, B. J. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2810256 · Cited by 50
Self-citationWireless sEMG-Based Body–Machine Interface for Assistive Technology Devices
Fall, C. L., Gagnon-Turcotte, G., Dube, J.-F., Gagne, J. S., Delisle, Y., Campeau‐Lecours, A., Gosselin, C., & Gosselin, B. J. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2642837 · Cited by 43
Self-citationA Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range
Xu, J., Wu, T., Liu, W., & Yang, Z. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2293821 · Cited by 43
Wang, J., Samal, A. K., & Green, J. R. (2014) · Workshop on Speech and Language Processing for Assistive Technologies · doi:10.3115/v1/w14-1906 · Cited by 41
“Researchers are also testing the efficacy of permanently implantable and wireless sensors (Chen et al., 2012; Park et al., 2012).”
BackgroundAntennas for Intraoral Tongue Drive System at 2.4 GHz: Design, Characterization, and Comparison
Kong, F., Qi, C., Lee, H., Durgin, G. D., & Ghovanloo, M. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2787118 · Cited by 42
“1(a)] [23] and the iTDS-a in the form of an arch-shaped retainer [Fig.”
BackgroundMethodSelf-citationSahadat, M. N., Alreja, A., & Ghovanloo, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2771235 · Cited by 40
Self-citationIntuitive wireless control of a robotic arm for people living with an upper body disability
Fall, C. L., Turgeon, P., Campeau‐Lecours, A., Maheu, V., Boukadoum, M., Roy, S., Massicotte, D., Gosselin, C., & Gosselin, B. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319370 · Cited by 35
“Like some other controllers [10], [11], the strength of the proposed controller lies on offering non-invasive, intuitive, wireless and wearable interfaces based on patients’ RFCs.”
BackgroundSelf-citationAn Arch-Shaped Intraoral Tongue Drive System with Built-in Tongue-Computer Interfacing SoC
Park, H., & Ghovanloo, M. (2014) · Sensors · doi:10.3390/s141121565 · Cited by 36
“To improve the mechanical stability of the system and better protect the users’ privacy, the intraoral version of the TDS (iTDS) is designed to locate inside the mouth on a dental retainer that clasps onto the teeth [12,27,28].”
BackgroundMethodResultInfluentialSelf-citationWang, J., Balasubramanian, A., de la Vega, L. G. M., Green, J. R., Samal, A. K., & Prabhakaran, B. (2013) · Lincoln (University of Nebraska) · Cited by 33
Qualitative assessment of Tongue Drive System by people with high-level spinal cord injury
Kim, J., Park, H., Bruce, J. A., MSPT, Rowles, D. M., Holbrook, J. S., Nardone, B., West, D. P., Laumann, A. E., UK, et al. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.08.0178 · Cited by 34
“Out of 11 participants, 10 preferred the concept of the iTDS, which was under development at the time of this study [21].”
BackgroundSelf-citationA Survey on Robotic Prosthetics: Neuroprosthetics, Soft Actuators, and Control Strategies
Jyothish, K. J., & Mishra, S. (2024) · ACM Computing Surveys · doi:10.1145/3648355 · Cited by 37
“The location of this magnet is tracked either using an External TDS (eTDS) headset (based on hall sensor) or an Intraoral TDS (iTDS) (based on 3-axis magnetometer sensor) [145] [92].”
BackgroundMethodAdaptive Matching Transmitter With Dual-Band Antenna for Intraoral Tongue Drive System
Kong, F., Zada, M., Yoo, H., & Ghovanloo, M. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2866960 · Cited by 28
Self-citationKim, J., Ham, Y., & Park, H. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3159953 · Cited by 26
Self-citationLipIO: Enabling Lips as both Input and Output Surface
Jingu, A., Tanaka, Y., & Lopes, P. (2023) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3580775 · Cited by 33
“ing [16, 30, 32], magnetoresistive sensing [43] and optical sensing [14, 52].”
BackgroundWireless Communication of Intraoral Devices and Its Optimal Frequency Selection
Park, H., & Ghovanloo, M. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2365804 · Cited by 24
“However, in an intraoral space, and become mismatched because changes considerably in dynamic intraoral environments in case of small-sized chip antennas while remains almost the same.”
BackgroundMethodInfluentialSelf-citationRetracted: Design of LoRa Antenna for Wearable Medical Applications
Alsaraira, A., Saraereh, O. A., Ali, A. A., & Alabed, S. J. (2023) · IEEE Access · doi:10.1109/access.2023.3254916 · Cited by 21
“In [23], an on-chip dual-frequency antenna was proposed with the help”
MethodRetractedA Low Energy-Noise 65nm CMOS Switched-Capacitor Resistive-Bridge Sensor Interface
Koay, K. C., & Pak Kwong, C. H. A. N. (2016) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2016.2625310 · Cited by 21
“mentation amplifier enables ease of integration for the resource sharing tasks [7]–[10].”
BackgroundJiang, B., Kim, J., & Park, H. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3013858 · Cited by 18
“For example, commands could be issued only if the same sensor was activated for more than certain amount of time, which is called the dwelling time [9].”
BackgroundInfluentialSelf-citationRothfuss, M. A., Franconi, N. G., Unadkat, J. V., Gimbel, M. L., Star, A., Mickle, M. H., & Sejdić, E. (2016) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2016.2588504 · Cited by 17
“The receiver sensitivity of the external CC1110F32 at 500 kBaud at 915MHz is -86 dBm, and the transmit power on the implant device was set to 10 dBm.”
BackgroundInfluentialSun, R., Zhou, X., Steeper, B., Zhang, R., Yin, S., Li, K., Wu, S., Tilsen, S., Guimbretière, F. V., & Zhang, C. (2023) · International Symposium on Wearable Computers · doi:10.1145/3594738.3611358 · Cited by 16
“Many previous works aim to recognize tongue gestures by instrumenting the tongue or face usingmagnetic sensors [12], EMG sensors [13], or optical sensors [6].”
BackgroundKong, F., Ghovanloo, M., & Durgin, G. D. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2913623 · Cited by 16
“a dual-band system was proposed, which operated at 27 MHz and 433 MHz [9].”
Self-citationEyelid Drive System: An Assistive Technology Employing Inductive Sensing of Eyelid Movement
Graybill, P. P., & Kiani, M. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2882510 · Cited by 16
Self-citationDavanzo, N., & Avanzini, F. (2020) · IEEE Access · doi:10.1109/access.2020.3019978 · Cited by 16
Tapping into tongue motion to substitute or augment upper limbs
Ghovanloo, M., Sahadat, M. N., Zhang, Z., Kong, F., & Sebkhi, N. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2262109 · Cited by 19
Self-citationFitts’ Law Based Performance Metrics to Quantify Tremor in Individuals With Essential Tremor
Kim, J., Wichmann, T., Inan, O. T., & DeWeerth, S. P. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3129989 · Cited by 15
Self-citationWheelchair control system for the disabled based on EMOTIV sensor gyroscope
Jameel, H. F., Gharghan, S. K., & Mohammed, S. L. (2022) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2022.104686 · Cited by 13
Toward an Ultralow-Power Onboard Processor for Tongue Drive System
Viseh, S., Ghovanloo, M., & Mohsenin, T. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2387683 · Cited by 13
“The sensors, analog front end, and transmitter have been extensively explained, in detail, in an earlier publication [10].”
BackgroundSelf-citationPirrera, A., Meli, P., Dominicis, A. D., Lepri, A., & Giansanti, D. (2022) · Healthcare · doi:10.3390/healthcare11010101 · Cited by 15
Antennas and Propagation for In-Mouth Tongue-Controlled Devices in Wireless Body Area Networks
Chandra, R., & Johansson, A. J. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2366092 · Cited by 12
Reconfigurable Spintronics Wheatstone Bridge Sensors With Offset Voltage Compensation at Wafer Level
Franco, F., Cardoso, S., & Freitas, P. P. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896379 · Cited by 12
“Meanwhile, bridge offset reduction has been exploited through continuous-time modulation techniques based on auto-zeroing [9] and chopping methods [10].”
MethodComparison of low-power biopotential processors for on-the-fly spike detection
Gagnon-Turcotte, G., Camaro, C.-O. D., & Gosselin, B. J. (2015) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2015.7168755 · Cited by 11
“This family of MCUs has been previously used in several biomedical monitoring applications, like in [4], [11] and [12], which makes it a perfectly suited platform for the implementation and characterization of our spike detectors.”
MethodSelf-citationConcept of cost-effective power-assisted wheelchair: Human-in-the-loop subsystem
Vorobyov, M., & Galkin, I. (2017) · IEEE Workshop on Advances in Information, Electronic and Electrical Engineering (AIEEE) · doi:10.1109/aieee.2017.8270559 · Cited by 10
“Operation of chin or tongue controllers, even if they are very advanced like in described in [13], [14], [15], [16], [17] and [18], as well as sip-and-puff systems may bring significant discomfort the wheelchair users.”
BackgroundKong, F., Zada, M., Yoo, H., & Ghovanloo, M. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351709 · Cited by 10
Self-citationPalatal Electrotactile Display Outperforms Visual Display in Tongue Motor Learning
Jiang, B., Kim, J., & Park, H. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3156398 · Cited by 10
Self-citationDevelopment and preliminary evaluation of an intraoral tongue drive system
Park, H., Kim, J., & Ghovanloo, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346141 · Cited by 10
Self-citationSannino, G., Sbardella, D., Cianca, E., Ruggieri, M., Coletta, M., & Prasad, R. (2016) · Wireless Personal Communications · doi:10.1007/s11277-016-3244-6 · Cited by 10
Park, B., Biswas, S., & Park, H. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3070867 · Cited by 9
Self-citationA High Performance Delta-Sigma Modulator for Neurosensing
Xu, J., Zhao, M., Wu, X., Islam, M., & Yang, Z. (2015) · Sensors · doi:10.3390/s150819466 · Cited by 8
“Introduction Growing concerns for human health have stimulated the development of biomedical devices [1–17], such as biosensors for recording neural spikes, field potentials, electroencephalography (EEG), electrocardiography (ECG), electromyography (EMG), and so on.”
BackgroundClassification of Nonverbal Human Produced Audio Events: A Pilot Study
Bouserhal, R. E., Chabot, P., Sarria-Paja, M., Cardinal, P., & Voix, J. (2018) · Interspeech (USB) · doi:10.21437/interspeech.2018-2299 · Cited by 8
“Tongue movements have been extensively explored as a silent interface for people with limited mobility [12, 13].”
BackgroundA wireless multichannel optogenetic headstage with on-the-fly spike detection
Turcotte, G. G., Camaro, C.-O. D., Kisomi, A. A., Ameli, R., & Gosselin, B. J. (2015) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2015.7168994 · Cited by 7
“Finally, the control unit is based on a low-power MCU from the MSP430 family of Texas Instruments, which has been previously used in several biomedical monitoring applications, like in [3], [9] and [10].”
MethodSelf-citationKim, Y., Lee, J., & Lee, B. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3401846 · Cited by 6
“1(b) [6], [7], [8], [9], [10], [11], [12].”
Ahlawat, S., Kanaujia, B. K., Rambabu, K., Peter, I., & Matekovits, L. (2023) · Scientific Reports · doi:10.1038/s41598-023-36717-w · Cited by 6
Smartphone-compatible robust classification algorithm for the Tongue Drive System
Ayala-Acevedo, A., & Ghovanloo, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981670 · Cited by 6
“A prototype based of dental retainers, called intraoral TDS (iTDS) has also been recently demonstrated [4].”
MethodSelf-citationCheah, L. A., Gilbert, J. M., González, J. A., Bai, J., Ell, S. R., Green, P., & Moore, R. K. (2017) · Communications in computer and information science · doi:10.1007/978-3-319-54717-6 · Cited by 6
A Gaze-Based Virtual Keyboard Using a Mouth Switch for Command Selection
Soundarajan, S., & Cecotti, H. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512929 · Cited by 7
“that can move fast and accurately [9]–[11].”
Kong, F., Mirbozorgi, S. A., Lee, B., & Ghovanloo, M. (2017) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8052967 · Cited by 5
Self-citationDensor: An Intraoral Battery-Free Sensing Platform
Dsouza, V., Pronk, J., Peppelman, C., Madariaga, V. I., Pereira‐Cenci, T., Loomans, B. A. C., & Pawełczak, P. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3699746 · Cited by 7
“Applications include assistive technology for people with disabilities [98] (see also Table 1, second column) and silent wireless control [28].”
Wearable and Non-Invasive Assistive Technologies
Ghovanloo, M., & Huo, X. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-418662-0.00009-x · Cited by 8
Self-citationKong, F., Sahadat, M. N., & Ghovanloo, M. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584669 · Cited by 5
“The early version of the iTDS was developed in the form of retainer mounted unto the upper teeth, under the palate [9].”
MethodSelf-citationMCU-less biphasic electrical stimulation circuit for miniaturized neuromodulator
Das, H., & Park, H. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00239-7 · Cited by 2
“Real-time wireless power transfer has been employed to eliminate the need of battery and reduce the footprint of the system [13, 14].”
MethodSelf-citationTongue-Supported Human-Computer Interaction systems: A review
Khan, M. M., Sherazi, H. I., & Quain, R. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943864 · Cited by 4
“So the system would also pose financial challenges to the patients [15].”
BackgroundMethodAlteration of Mastication Force via Intraoral Closed-Loop Electrical Stimulation
Zheng, J., Jiang, B., Biswas, S., Lee, S., Bumann, E. E., Lever, T. E., Kim, J. H., & Park, H. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3535681 · Cited by 3
“Lastly, as demonstrated in the prior works of wireless intraoral devices as forms of palatal retainer and arch-shaped retainer [60], [61], MCU functionalities can be fully integrated into the CMOS system-on-chip (SoC).”
Self-citationTowards a wireless optical stimulation system for long term in-vivo experiments
Mirbozorgi, S. A., Ameli, R., Sawan, M., & Gosselin, B. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944013 · Cited by 3
Self-citationDevelopment of a non-contact tongue-motion acquisition system
Miyauchi, M., Kimura, T., & Nojima, T. (2012) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/2380296.2380329 · Cited by 3
Implementation of Gesture Control Robotic Arm for Automation of Industrial Application
Hande, S. A., & Chopde, N. R. (2020) · International Journal of Scientific Research in Science and Technology · doi:10.32628/ijsrst207442 · Cited by 3
Low-power adaptive spike detector based on a sigma-delta control loop
Gagnon-Turcotte, G., Sawan, M., & Gosselin, B. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318819 · Cited by 3
Self-citationWearable and non-invasive assistive technologies
Ghovanloo, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00022-x · Cited by 5
Self-citationKhan, M. M., Smart, S. J., Bogaardt, H., Zubairi, J. A., & Yanushkevich, S. N. (2024) · IEEE Access · doi:10.1109/access.2024.3399199 · Cited by 2
“Attention is also being paid to the cost and operational difficulty related issues of the TSIS’s [7], [24], [25], [26].”
BackgroundIntegrated oral wearable devices: From smart sensing to closed-loop theranostics
Shi, F., Li, C., Du, J., Han, Q., Zhang, F., Lee, M.-G., Kim, D., Wang, K., Wang, L., Xu, L., et al. (2026) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2026.217750 · Cited by 2
Self-citationM2M Communications for Intraoral Sensors: A Wireless Communications Perspective
Sannino, G., Cianca, E., Hamitouche, C., & Ruggieri, M. (2015) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-319-27072-2_15 · Cited by 2
Wearable wireless User Interface Cursor-Controller (UIC-C)
Marjanovic, N., Kerr, K., Aranda, R., Hickey, R. J., & Esmailbeigi, H. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037697 · Cited by 4
“Wireless Magnetoresistive tracking devices were developed in the recent decade and require a tongue piercing or adhesive attachments [15-16].”
BackgroundResin: a Vocal Tract Resonances and Head Based Accessible Digital Musical Instrument
Davanzo, N., & Avanzini, F. (2021) · Audio Mostly Conference (AM) · doi:10.1145/3478384.3478403 · Cited by 2
“Other detection methods, not used in musical contexts, include the use of textile pressure [2], ultrasound [13, 29], magnetoresistive [21] or optical sensors [11, 23].”
MethodA Technical Review on Development of an Advanced Electromechanical System
Taghavi, N., Luecke, G. R., & Jeffery, N. D. (2020) · Computers · doi:10.3390/computers9010019 · Cited by 2
“Most electromechanical systems include several sensors, actuators, embedded controllers, such as computers, microcontrollers or programmable chips [8], and a power supply system.”
BackgroundAhlawat, S., Zaidi, A. M., Kanaujia, B. K., Kaim, V., & Rengarajan, S. R. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3576103 · Cited by 1
“It comprises of an array of sensor modules, control, and supply units integrated according to their proposed mouth placement to facilitate the transmission of the user’s intentions [17], [24], [25].”
InfluentialSannino, G., Cianca, E., Coletta, M., Ruggieri, M., Sbardella, D., & Prasad, R. (2015) · IEEE International Symposium on Systems Engineering · doi:10.1109/syseng.2015.7302781 · Cited by 1
A Multichannel Wireless sEMG Sensor Endowing a $0.13 \ \mu \mathrm{m}$ CMOS Mixed-Signal SoC
Gagnon-Turcotte, G., Fall, C. L., Mascret, Q., Bielmann, M., Bouyer, L. J., & Gosselin, B. J. (2018) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2018.8572118 · Cited by 1
“13 μm mixed-signal SoC conditioning and digitizing 10 sEMG channels in parallel, 2) a low-power MSP430F5328 microcontroller unit (MCU) from Texas Instruments, USA, an MCU family used in many low-power biomedical monitoring applications [12], [13] available in a tiny 5 x 5 mm micro BGA package, 3) a 2.”
MethodSelf-citationKong, F., Jia, Y., & Ghovanloo, M. (2020) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas48704.2020.9184522 · Cited by 1
“difficulty for the users to move their tongues [9].”
BackgroundSelf-citationSecure and Connected Telehealth Approach to Mitigating Concussion Risks in Student Athletes
Morrison, M. A., Humphrey, G., Daigle, J. N., Ralston, J. D., Jason, T., & Ralston, A. B. (2016) · International Conference on Computer Communications and Networks (ICCCN) · doi:10.1109/icccn.2016.7568570
Ruggieri, M., & Sannino, G. (2017) · Wiley eBooks · doi:10.1002/9781119341451.ch6
INTERACTIVE OBJECT SEGMENTATION WITH NOISY BINARY INPUTS
Canal, G., Manivasagam, S., Liang, S., & Rozell, C. J. (2018) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2018.8646574
“For example, such input devices might involve brain-computer interfaces [4], input switches activated by gross motor movements [5], or command entry through non-traditional motor commands such as the tongue drive [6].”
BackgroundInvestigations on upper limb prosthesis control with an active elbow
Mérad, M. (2017) · theses.fr (ABES) · doi:10.70675/49868946zf54fz40ccza88bzda97441889ed · Cited by 2
“Ability to voluntarily move the tongue is often one of the last remaining capability of severely impaired patients, hence tongue tracking devices have been developed (Park et al., 2012; Struijk, 2006; Struijk et al., 2009).”
BackgroundIkram, M., Mugheri, A. A., Abdelhamid, A. S., Kamel, Y. A., Alqadami, A. S. M., Akhter, Z., Hussain, N., Jehangir, S. S., & Sultan, K. (2026) · Sensors and Actuators Reports · doi:10.1016/j.snr.2026.100530
Metadata
- Authors
- Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M.
- Affiliations
- Georgia Institute of Technology (US)
- Université Laval (CA)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-12
- Volume
- 6
- Issue
- 6
- Pages
- 571-585
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- PMC
- PMC4445236
- OpenAlex
- W2077107286
- Semantic Scholar
- 33829cd315267476664a44e4420111f7f6592bd7
- Cited by
- 79
- References
- 32
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 3 · 2020: 6 · 2019: 2 · 2018: 12 · 2017: 8 · 2016: 6 · 2015: 8 · 2014: 12 · 2013: 2 · 2012: 2
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (RC1EB010915)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- tongue drive system, magnetoresistive sensors, orthodontic retainers, system-on-chip, analog front-end, dual-band transmitter, ISM band, power management integrated circuits, low-power CMOS
- MeSH terms
- Biomedical Engineering, Equipment Design, Humans, Self-Help Devices, Spinal Cord Injuries, Telemetry, Tongue, User-Computer Interface, Wireless Technology, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.