A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Open accessThe DOI matches its Crossref record; 30 of the 32 references it cites were found in a registry or an index.
Abstract
Tongue drive system (TDS) is a tongue-operated, minimally invasive, unobtrusive, and wireless assistive technology (AT) that infers users' intentions by detecting their voluntary tongue motion and translating them into user-defined commands. Here we present the new intraoral version of the TDS (iTDS), which has been implemented in the form of a dental retainer. The iTDS system-on-a-chip (SoC) features a configurable analog front-end (AFE) that reads the magnetic field variations inside the mouth from four 3-axial magnetoresistive sensors located at four corners of the iTDS printed circuit board (PCB). A dual-band transmitter (Tx) on the same chip operates at 27 and 432 MHz in the Industrial/Scientific/Medical (ISM) band to allow users to switch in the presence of external interference. The Tx streams the digitized samples to a custom-designed TDS universal interface, built from commercial off-the-shelf (COTS) components, which delivers the iTDS data to other devices such as smartphones, personal computers (PC), and powered wheelchairs (PWC). Another key block on the iTDS SoC is the power management integrated circuit (PMIC), which provides individually regulated and duty-cycled 1.8 V supplies for sensors, AFE, Tx, and digital control blocks. The PMIC also charges a 50 mAh Li-ion battery with constant current up to 4.2 V, and recovers data and clock to update its configuration register through a 13.56 MHz inductive link. The iTDS SoC has been implemented in a 0.5-μm standard CMOS process and consumes 3.7 mW on average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“2227962 leveraging advancements in neurosciences, microelectronics, wireless communications, and computing [2]–[8].”
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 2×
“TABLE I FREQUENCY-DEPENDENT ATTENUATION CHARACTERISTICS OF TISSUE [33]”
Calabrese, V. P. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490230111048 · Cited by 2,501
Field and wave electromagnetics
Cheng, D. K. (1983) · Cited by 2,199
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Assistive Technologies: Principles and Practice
Cook, A. M., & Polgar, J. M. (1995) · Cited by 1,010
System for assisted mobility using eye movements based on electrooculography
Barea, R., Boquete, L., Mazo, M., & Lopez, E. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806829 · Cited by 486
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321 · cited 2×
“5 s before moving to another command position [13].”
Self-citationLee, H.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2010.2103172 · Cited by 227 · cited 2×
“This circuit also generates a short pulse for every detected bit “1” and applies it to the load-shift-keying (LSK) mechanism of the active rectifier [39].”
Self-citationA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazicioglu, R. F., Grundlehner, B., Harpe, P., Makinwa, K. A. A., & Van Hoof, C. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221
Research works printed but not linked: 8
- 2000, System and method to determine the location and orientation of an indwelling medical device
- rai, 2009, A 500 <formula formulatype="inline"><tex Notation="TeX">$\mu{\rm W}$</tex></formula> neural tag with 2 <formula formulatype="inline"><tex Notation="TeX">$\mu{\rm Vrms}$</tex></formula> AFE and frequency-multiplying MICS/ISM FSK transmitter, Proc IEEE ISSCC Dig Tech Papers
- 10.1109/TITB.2011.2158608 · DOI
- caruso, 0, A new perspective on magnetic field sensing, Honeywell Applications Note
- vieira, 0, Magnetoresistive Sensors for a Magnetometer
- 0, Origin Instrument Sip/Puff Switch
- capps, 2001, Near field or far field?, EDN Mag, 95
- giraldi, 1997, Independence day: Tongue-touch controls give Ben a more satisfying self-sufficient lifestyle, Teamrehab Report Mag
Cited by
Lee, Y., Howe, C., Mishra, S., Lee, D. S., Mahmood, M., Piper, M., Kim, Y., Tieu, K., Byun, H.-S., Coffey, J. P., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719573115 · Cited by 183
“Consequently, such devices add excessive mechanical and thermal loading and discomfort to a user, particularly considering that the oral mucosa (19, 20) is one of the most sensitive tissues in the body.”
BackgroundThe Tongue Enables Computer and Wheelchair Control for People with Spinal Cord Injury
Kim, J., Park, H., Bruce, J. A., Sutton, E., Rowles, D. M., Pucci, D., Holbrook, J. S., Minocha, J., Nardone, B., West, D. P., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006296 · Cited by 141
“In comparison to previous studies with a similar setup for centerout tapping (table S3), the throughput of able-bodied participants using a mouse was slightly higher than reported here (18, 53), but in the same range considering the SD (3.”
MethodResultSelf-citationAdaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review
Bocan, K., & Sejdić, E. (2016) · Sensors · doi:10.3390/s16030393 · Cited by 123
“Insensitive systems are designed for consistent operation over a range of environmental parameters, without the use of tuning components [35,52].”
BackgroundA 0.13- $\mu\text{m}$ CMOS SoC for Simultaneous Multichannel Optogenetics and Neural Recording
Gagnon-Turcotte, G., Khiarak, M. N., Ethier, C., De Koninck, Y., & Gosselin, B. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2865474 · Cited by 53
“LDO for the MCU and the wireless transceiver; 4) a small (5 × 5 mm2 micro-ball grid array (BGA) package), low-power MSP430F5328 MCU from Texas Instruments, USA, an MCU family used in many low-power biomedical applications [35]–[37]; 5) the implantable module holding the microelectrodes, the LEDs, and the optical fiber…”
Self-citationA Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 54
“A sophisticated power scheduling scheme is often used in medical devices as exemplified in [59] were a duty cycling is applied to the higher power consumption circuits.”
Self-citation
Metadata
- Authors
- Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M.
- Affiliations
- Georgia Institute of Technology (US)
- Université Laval (CA)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-12
- Volume
- 6
- Issue
- 6
- Pages
- 571-585
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- PMC
- PMC4445236
- OpenAlex
- W2077107286
- Semantic Scholar
- 33829cd315267476664a44e4420111f7f6592bd7
- Cited by
- 79
- References
- 32
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 3 · 2020: 6 · 2019: 2 · 2018: 12 · 2017: 8 · 2016: 6 · 2015: 8 · 2014: 12 · 2013: 2 · 2012: 2
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (RC1EB010915)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- tongue drive system, magnetoresistive sensors, orthodontic retainers, system-on-chip, analog front-end, dual-band transmitter, ISM band, power management integrated circuits, low-power CMOS
- MeSH terms
- Biomedical Engineering, Equipment Design, Humans, Self-Help Devices, Spinal Cord Injuries, Telemetry, Tongue, User-Computer Interface, Wireless Technology, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.