A Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This paper presents a frequency-shaping (FS) neural recording architecture and its implementation in a 0.13 μ m CMOS process. Compared with its conventional counterpart, the proposed architecture inherently rejects electrode offset, increases input impedance 5-10 fold, compresses neural data dynamic range (DR) by 4.5-bit, simultaneously records local field potentials (LFPs) and extracellular spikes, and is more suitable for long-term recording experiments. Measured at a 40 kHz sampling clock and ± 0.6 V supply, the recorder consumes 50 μW/ch, of which 22 μW per FS amplifier, 24 μ W per buffer, 4 μ W per 11-bit successive approximation register analog-to-digital converter (SAR ADC). The input-referred noise for LFPs and extracellular spikes are 13 μ Vrms and 7 μVrms, respectively, which are sufficient to achieve high-fidelity full-spectrum neural data. In addition, the designed recorder has a 3 pF input capacitance and allows " 11+4.5"-bit neural data DR without system saturation, where the extra 4.5-bit owes to the FS technique. Its figure-of-merit (FOM) based on data DR reaches 36.0 fJ/conversion-step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Both LFPs and extracellular spikes are used for information decoding [43]–[46].”
BackgroundBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“T HERE is a rapidly growing need for neuroscience tools, which can perform chronic, high-density recording together with powerful signal processing modules to facilitate information decoding [1]–[11].”
BackgroundA low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A 10-bit 50-MS/s SAR ADC With a Monotonic Capacitor Switching Procedure
Liu, C.-C., Chang, S.-J., Huang, G.-Y., & Lin, Y.-Z. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042254 · Cited by 1,329
Distinct roles for direct and indirect pathway striatal neurons in reinforcement
Kravitz, A. V., Tye, L. D., & Kreitzer, A. C. (2012) · Nature Neuroscience · doi:10.1038/nn.3100 · Cited by 972
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Cited by
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
A bioelectric neural interface towards intuitive prosthetic control for amputees
Nguyen, A. T., Xu, J., Jiang, M., Luu, D. K., Wu, T., Tam, W.-K., Zhao, W., Drealan, M. W., Overstreet, C. K., Zhao, Q., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3d3 · Cited by 52
Self-citationCulaclii, S., Kim, B., Lo, Y.-K., Li, L., & Liu, W. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2816464 · Cited by 34
“in [11] has demonstrated tolerance to an artifact in concurrent stimulation and recording by using a front-end amplifier design presented in [9] with increased dynamic range for low frequency”
Xu, J., Nguyen, A. T., Wu, T., Zhao, W., Luu, D. K., & Yang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2972013 · Cited by 29
Self-citation
Metadata
- Authors
- Xu, J., Wu, T., Liu, W., & Yang, Z.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2014-08
- Volume
- 8
- Issue
- 4
- Pages
- 510-527
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2050352276
- Cited by
- 41
- References
- 15
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range. https://app.cochat.ai/papers/10.1109/tbcas.2013.2293821
- The paper
- Xu, J., Wu, T., Liu, W., & Yang, Z. (2014). A Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2013.2293821
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.