CoChat

A Real-Time QRS Detection System With PR/RT Interval and ST Segment Measurements for Wearable ECG Sensors Using Parallel Delta Modulators

Tang, Xiaochen, Hu, Qisong, Tang, Wei · 2018 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 94

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper presents a real-time electrocardiogram (ECG) monitoring system for wearable devices. The system is based on the proposed parallel delta modulator architecture with local maximum point and local minimum point algorithms to detect QRS and PT waves. Therefore, using the proposed system and algorithm, real-time PR and RT intervals, and ST segment measurements can be achieved in long-term wearable ECG recording. The algorithm is tested with the MIT-BIH Arrhythmia Database for QRS complex detection and with the QT Database for the P and T wave detections. The simulation result shows that the algorithm achieves above 99%, 91%, and 98% accuracy in the QRS complex, P wave, and T wave detections, respectively. Experimental results are presented from the system prototype, in which the parallel delta modulator circuits are fabricated in IBM 0.13 $\mu \text{m}$ standard CMOS technology and the algorithms are implemented in a Xilinx Spartan-6 field programmable gate array (FPGA). The parallel delta modulators consume 720 nW at 1 kHz sampling rate with $\pm$0.6 V power supply. The proposed system has the potential to be applied in future long-term wearable ECG recording devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2018.2823275

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Tang, X., Hu, Q., & Tang, W.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2018-08
Volume
12
Issue
4
Pages
751-761
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2886357685
Cited by
94
References
5
FWCI
6.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.