Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
The DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.
Abstract
The paper presents the design and validation of body-conformal active ultrasound patches with integrated imaging and modulation modalities for image-guided neural therapy. A mechanically-flexible linear 64-element array of piezoelectric transducers with a resonance frequency of 5 MHz was designed for nerve localization. A second 8-element array using larger elements was integrated on the wearable probe for low intensity focused ultrasound neuromodulation at a resonance frequency of 1.3 MHz. Full-wave simulations were used to model the flexible arrays and estimate their generated pressure profiles. A focal depth of 10-20 mm was assumed for beamforming and focusing to support modulation of the vagus, tibial, and other nerves. A strain sensor integrated on the probe provides patient-specific feedback information on array curvature for real-time optimization of focusing and image processing. Each patch also includes high voltage (HV) multiplexers, transmit/receive switches, and pre-amplifiers that simplify connectivity and also improve the signal-to-noise ratio (SNR) of the received echo signals by ∼ 5 dB. Experimental results from a flexible prototype show a sensitivity of 80 kPa/V with ∼ 3 MHz bandwidth for the modulation and 20 kPa/V with ∼ 6 MHz bandwidth for the imaging array. An algorithm for accurate and automatic localization of targeted nerves based on using nearby blood vessels (e.g., the carotid artery) as image markers is also presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [524]
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155 · cited 4×
“, based on a partially-pretrained DCNN named AlexNet [48].”
MethodInfluentialCalculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493 · cited 1×
“imaging array was assessed in silico using the Field II ultrasound simulation package [45], [46].”
MethodBoone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Diagnostic ultrasound Imaging : Inside out
(2005) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2005-861725 · Cited by 761 · cited 1×
“arrays to obtain high-resolution images that allow differentiation of adjacent structures based on their echogenicity [39].”
BackgroundUltrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745 · cited 1×
“Ultrasound pressure waves can produce both thermal and mechanical effects while interacting with biological tissue [36], [37].”
Background
Research works printed but not linked: 3
- aggarwal, 0, Automated positioning of ultrasonic probes, Proc Nat Aerosp Electron Conf, 1
- kaczmarek, 1987, et�al
- jensen, 0, Field: A program for simulating ultrasound systems, Proc 10th NordicBaltic Conf Biomed Imag, 4, 351
Cited by
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
A conformable phased-array ultrasound patch for bladder volume monitoring
Zhang, L., Marcus, C., Lin, D., Mejorado, D., Schoen, S. J., Pierce, T. T., Kumar, V., Fernandez, S. V., Hunt, D., Li, Q., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01068-x · Cited by 148
La, T., & Le, L. H. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100798 · Cited by 150
Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring
Zhao, L., Liang, C., Huang, Y., Zhou, G., Xiao, Y., Ji, N., Zhang, Y., & Zhao, N. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00835-6 · Cited by 149
“Pashaei et al. 80 proposed a pre-ampli fi er design in a fl exible ultrasound probe circuit to maintain the signal-to-noise ratio (SNR) during signal transmission from the probe to the receiver, thus enhancing the detection sensitivity to small organs, e.g., blood vessels.”
An Emerging Era: Conformable Ultrasound Electronics
Zhang, L., Du, W., Kim, J., Yu, C., & Dağdeviren, C. (2023) · Advanced Materials · doi:10.1002/adma.202307664 · Cited by 108
Emerging Wearable Ultrasound Technology
Huang, H., Wu, R. S., Lin, M., & Xu, S. H. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3327143 · Cited by 90
“In humans, a flexible ultrasound device was designed to stimulate the peripheral nerves, such as the vagus and tibial nerves [156], which could help treat conditions, such as epilepsy and various psychiatric disorders.”
BackgroundCotero, V. E., Graf, J. F., Miwa, H., Hirschstein, Z., Qanud, K., Huerta, T. S., Tai, N., Ding, Y., Jimenez-Cowell, K., Tomaio, J. N., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00870-w · Cited by 89
Stretchable Electronic Facial Masks for Sonophoresis
Li, S., Xu, J., Li, R., Wang, Y., Zhang, M., Li, J., Yin, S., Liu, G., Zhang, L., Li, B., et al. (2022) · ACS Nano · doi:10.1021/acsnano.1c11181 · Cited by 80
Emerging Wearable Acoustic Sensing Technologies
Liu, T., Mao, Y., Dou, H., Zhang, W., Yang, J., Wu, P., Li, D., & Mu, X. (2025) · Advanced Science · doi:10.1002/advs.202408653 · Cited by 93
Xue, X., Wu, H., Cai, Q., Chen, M., Moon, S., Huang, Z., Kim, T., Peng, C., Feng, W., Sharma, N., et al. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3333318 · Cited by 77
“Furthermore, the probe incorporates a strain sensor that offers customized curvature feedback for real-time enhancements in focusing and image processing, ultimately leading to enhanced beam profiles [155].”
BackgroundMethodInfluentialWearable ultrasound technology
Zhou, S., Park, G., Lin, M., Yang, X., & Xu, S. H. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00329-y · Cited by 79
“The piezoelectric coefficient ( d 33 , usually ranging from 20 to 1,550 pC N −1 ) quantifies conversion between electric field and mechanical strain 29 and is defined by:”
Emerging ultrasonic bioelectronics for personalized healthcare
Jiang, L., & Wu, J. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101110 · Cited by 67
Chen, W., Liu, J., Lei, S., Yang, Z., Zhang, Q., Li, Y., Huang, J., Dong, Y., Zheng, H., Wu, D., et al. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3266367 · Cited by 61
“This is largely due to the incomplete characterization of electrical and acoustic performance, unsuitable array size, and inaccurate estimation of array shape [23].”
BackgroundMethodElloian, J. M., Jadwiszczak, J., Arslan, V., Sherman, J. D., Kessler, D. O., & Shepard, K. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-20721-7 · Cited by 59
Clinical, Safety, and Engineering Perspectives on Wearable Ultrasound Technology: A Review
Song, P., André, M. P., Chitnis, P. V., Xu, S. H., Croy, T., Wear, K. A., & Sikdar, S. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3342150 · Cited by 64
“To date, the majority of the reported wearable US devices support A-mode, M-mode, and B-mode imaging [8], [18], [69], [81], [105], [110], [121], [122].”
BackgroundBai, X., Wang, D., Zhen, L., Cui, M., Liu, J., Zhao, N., Lee, C., & Yang, B. T. (2024) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad62c6 · Cited by 59
“In addition, researchers have used flexible ultrasound arrays for neural regulation [115], and even use it for brain stimulation in conjunction with brain-computer interface (BCI) technology [116].”
An Integrated 2D Ultrasound Phased Array Transmitter in CMOS With Pixel Pitch-Matched Beamforming
Costa, T. L., Shi, C., Tien, K., Elloian, J. M., Cardoso, F. A., & Shepard, K. L. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3096722 · Cited by 54
Xue, X., Zhang, B., Moon, S., Xu, G., Huang, C., Sharma, N., & Jiang, X. (2023) · Biosensors · doi:10.3390/bios13010134 · Cited by 51
“Several biomedical applications of the wearable US devices are gaining popularity, including fetal heart rate monitoring [32], blood pressure monitoring [33,34], brain imaging [35], intravascular ultrasound (IVUS) imaging [36], neural modulation [37,38], local pulse wave velocity monitoring [39], and blood flow measur…”
Progress in wearable acoustical sensors for diagnostic applications
Li, Y., Li, Y., Zhang, R., Li, S., Liu, Z., Zhang, J., & Fu, Y. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115509 · Cited by 49
Wearable ultrasound devices: An emerging era for biomedicine and clinical translation
Hu, H., Hu, C., Guo, W., Zhu, B., & Wang, S. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107401 · Cited by 53
Skin-Conformable Flexible and Stretchable Ultrasound Transducer for Wearable Imaging
Chen, J., Liu, J., Chen, W., Shang, D., Zhang, Q., Li, Y., Zheng, H., Gu, D., Wu, D., & Ma, T. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3352655 · Cited by 41
“Moreover, encapsulating arrays in silicone rubber [19], bonding flexible arrays on flexible printed circuits [20], using MEMS technology to fabricate flexible arrays [21], and adopting “island-bridge” structures with serpentine hinges [22], [23], [24] also succeed.”
MethodDesign and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation
Ilham, S. J., Kashani, Z., & Kiani, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3133133 · Cited by 38
Flexible Thin-Film PZT Ultrasonic Transducers on Polyimide Substrates
Liu, T., Dangi, A., Kim, J. N., Kothapalli, S., Choi, K., Trolier-McKinstry, S. E., & Jackson, T. N. (2021) · Sensors · doi:10.3390/s21031014 · Cited by 37
“Wearable ultrasonic systems attached to the human body would enable more personalized and adaptive medical diagnoses and treatments, such as for neuromodulation [6].”
BackgroundA Review of Ultrasound Neuromodulation Technologies
Javid, A., Ilham, S. J., & Kiani, M. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3299750 · Cited by 35
Body Conformal Linear Ultrasound Array for Combined Ultrasound and Photoacoustic Imaging
Roy, K., Agrawal, S., Dangi, A., Liu, T., Chen, H., Jackson, T. N., Pratap, R., & Kothapalli, S. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251458 · Cited by 30
“A few developments have already taken place in this field and there is some literature available that report fabrication of these arrays using both bulk [6], [7] and thin film piezoelectric material [8]–[10].”
BackgroundLiu, H., Fan, J., Lin, X., Lin, K., Wang, S., Liu, S., Wang, F., & Song, J. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00354-8 · Cited by 23
Noda, T., Azuma, T., Ohtake, Y., Sakuma, I., & Tomii, N. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3210701 · Cited by 22
“Flexible US probes, which have been recently developed, have the potential to overcome these limitations [4], [5], [6], [7], [8].”
BackgroundReview on Wearable System for Positioning Ultrasound Scanner
Li, L., Zhao, L., Hassan, R., & Ren, H. (2023) · Machines · doi:10.3390/machines11030325 · Cited by 22
Wearable Ultrasound System Using Low-Voltage Time Delay Spectrometry for Dynamic Tissue Imaging
Bashatah, A., Mukherjee, B., Rima, A. H., Patwardhan, S., Otto, P. R., Sutherland, R., King, E. L., Lancaster, B., Aher, A., Gibson, G., et al. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3414419 · Cited by 19
“Conformal ultrasonic patch transducer arrays have been developed for imaging the carotid artery to determine the central blood pressure [8], [9], image-guided neural therapy [10] and breast tissue imaging [11].”
MethodKhalilnejad, A., French, R. H., & Abramson, A. R. (2021) · Energy · doi:10.1016/j.energy.2021.121117 · Cited by 18
A weavable and wearable polymer ultrasonic transducer with a large bandwidth
Zou, J., Guo, X., Wu, J., Xu, D., Xu, K., Chen, P., Ta, D., & Peng, H. (2024) · Science China Materials · doi:10.1007/s40843-024-2945-7 · Cited by 17
“However, current rigid bulk ultrasonic devices are often unsuitable for the inherent requirements of flexibility, miniaturization, and comfort in medical wearables [16–19].”
Bone Fracture Healing under the Intervention of a Stretchable Ultrasound Array
Liu, H., Ding, S., Lin, X., Wang, S., Wang, Y., Feng, Z., & Song, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c02426 · Cited by 16
Detrusor overactivity assessment using ultrasound bladder vibrometry
Rosen, D., Husmann, D. A., Mynderse, L. A., Kelly, T. F., Alizad, A., & Fatemi, M. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac2c5c · Cited by 15
“Because ultrasound is portable, and potentially evenwearable (Pashaei et al 2020), UBVmay offer an attractive avenue for assessingDOduring ambulationwhichwould substantially increase the urologist’s acumen.”
BackgroundShape estimation of flexible ultrasound arrays using spatial coherence: A preliminary study
Omidvar, A., Rohling, R. N., Cretu, E., Cresswell, M., & Hodgson, A. J. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107171 · Cited by 15
Towards High-Resolution Ultrasound Neuromodulation With Crossed-Beam Phased Arrays
Ilham, S. J., & Kiani, M. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3285724 · Cited by 13
Waataja, J. J., Asp, A. J., & Billington, C. J. (2023) · Biomedicines · doi:10.3390/biomedicines11092452 · Cited by 11
“Flexible bodyconformal hand-held ultrasound devices are under development [48], which may help bridge this technical gap.”
Background28-nm CMOS Ultrasound AFE With Split Attenuation for Optimizing Gain-Range, Noise, and Area
Yu, X., Chen, Z., Wu, S., Liu, L., Chi, H., Ye, F., & Ren, J. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3315282 · Cited by 10
“The AFE not only pre-processed the echo signal collected by the transducer but also provided input impedance matching with the output electrical matching layers of the transducers or coaxial cables [4], [5], [6], [7].”
BackgroundTextile-based shape-conformable and breathable ultrasound imaging probe
Noda, T., Takamatsu, S., Yamamoto, M., Tomita, N., Itoh, T., Azuma, T., Sakuma, I., & Tomii, N. (2024) · Communications Materials · doi:10.1038/s43246-024-00591-4 · Cited by 12
“Inotherstudies, fl exible US probes have been developed, which have US elements arranged on thin and fl exible sheets 17,18 .”
Low-Noise Low-Power Ultrasound AFE With Continuous TGC Built in Both TIA and Beamformer
Yu, X., Wang, Y., Ye, F., & Ren, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3302648 · Cited by 10
“In portable ultrasonic equipment and other fully integrated probes, this low-noise amplifier is usually connected directly to the ultrasonic transducer rather than through coaxial cable [9], [10], [11].”
BackgroundMemory-efficient low-compute segmentation algorithms for bladder-monitoring smart ultrasound devices
Song, Z., Asiedu, M., Wang, S., Li, Q., Ozturk, A., Mittal, V., Schoen, S. J., Ramaswamy, S. M., Pierce, T. T., Samir, A. E., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-42000-9 · Cited by 11
A Wearable Dual-Mode Probe for Image-Guided Closed-Loop Ultrasound Neuromodulation
Huan, J., Pashaei, V., Majerus, S. J. A., Bhunia, S., & Mandal, S. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3425858 · Cited by 7
“The template matching algorithm is easier to implement with a limited amount of image data than higher-performance algorithms based on CNNs [49].”
Self-citationZhao, J., Huang, Y., Zhang, Y., Xie, Y., Wei, G., Li, Y., & Wang, S. (2026) · Bioengineering · doi:10.3390/bioengineering13030345 · Cited by 7
“Several recent studies have demonstrated preliminary closed-loop architectures that integrate sensing, feedback, and therapy [7,37,38,48].”
InfluentialReview of Current Simple Ultrasound Hardware Considerations, Designs, and Processing Opportunities
Jonveaux, L., Schloh, C., Meng, W. L., Arija, J., & Rintoul, J. L. (2022) · Journal of Open Hardware · doi:10.5334/joh.28 · Cited by 9
Automatic Measurement of the Carotid Blood Flow for Wearable Sensors: A Pilot Study
Matera, R., & Ricci, S. (2021) · Sensors · doi:10.3390/s21175877 · Cited by 5
“The proposed sensor features a relatively wide field of view that maximizes the chances for the non-expert user to locate the vessel even without the help of a B-mode display; an algorithm automatically locates the vessel lumen in the B-mode images [17], places the Doppler lines in the right position, and performs an…”
BackgroundFPGA-Accelerated CNN Reconstruction for Low-Power Sparse-Array Ultrasound Imaging
Imenabadi, R. M., Thoreson, G. R., Brown, K., & Bhatia, D. K. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3630483 · Cited by 4
“This advancement extends the utility of conventional diagnostic US to continuous monitoring, opening a wide range of clinical applications including blood pressure monitoring and bladder volume assessment [23], [24], [25].”
Flexible Piezoelectric Sensors for Miniaturized Sonomyography
Cerezo‐Sánchez, M., Zuo, S., Moldovan, A. C., Cochran, S., Nazarpour, K., & Heidari, H. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630342 · Cited by 4
“In order to design such a transducer, a similar methodology to that provided in recent studies was followed [10], with an additional step at the final stage to analyse the performance of the designed sensor as an ultrasonic transmitter and not just a receiver, as shown in Fig.”
MethodHojo, C., Kawagishi, H., Shigemune, H., & Tsumura, R. (2023) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft55895.2023.10121984 · Cited by 4
Zhang, J., Ding, K., & Bell, M. A. L. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10794118 · Cited by 3
“To obtain correct element positions, previous work proposed to attach external sensors to the flexible array such as a shape sensing fiber [8], a strain sensor [9], and optical markers paired with an infrared tracker [10], [11].”
You, L., 瞿亦容, Chen, Y., Wang, Y., Shen, L., & Ge, J. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00537-5 · Cited by 3
“…fl exible polyurethane rubber with tungsten particles, struggle to balance the two desirable properties of high acoustic attenuation and fl exibility 97,98 composite backing layer materials that can prevent interference from acoustic energy radiated backward from the piezoelectric element while…”
Seeing inside a body in motion
Tan, P., & Lu, N. (2022) · Science · doi:10.1126/science.adc8732 · Cited by 3
Evaluation of a Dual Linear Flexible Ultrasound Array for Surgical Interventional Guidance
Rostamikhanghahi, H., Ingram, M., Booth, B. G., & D’hooge, J. (2025) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2025.3560938 · Cited by 2
UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration
Frey, B. N., Hyun, D., Simson, W. A., Zhuang, L. L., Hashemi, H. S., Schneider, M. K., & Dahl, J. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3627525 · Cited by 2
“…these conventional transducers have provided immeasurable benefit to ultrasound imaging, the recent development of flexible-array ultrasound transducers opens the door to new applications for ultrasound, including continuous monitoring and wearable ultrasound technologies [1], [2], [3], [4], [5].”
Li, J., Li, G., Ma, C., Li, W., Yu, G., Xiang, L., & Yao, G. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01308-y · Cited by 3
“The next advancement in this fi eld involves merging clinical ultrasound imaging capabilities with fully integrated, wireless, and wearable fl exible biosensors.”
A High-Voltage ASIC for Ultrasound Neuromodulation with a Piezoelectric Transducer
Gougheri, H. S., & Kiani, M. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937761 · Cited by 2
“The systems in [13] and [14] utilize COTS components and still suffer from bulkiness (i.”
BackgroundA low-complexity and high-frequency ASIC transceiver for an ultrasound imaging system
Lee, J., Huh, K. Y., Kang, D., Lim, J., Lee, B. C., & Lee, B. (2024) · Biomedical Engineering Letters · doi:10.1007/s13534-024-00411-1 · Cited by 2
Imenabadi, R. M., Avanji, M. H., Brown, K., & Bhatia, D. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793917 · Cited by 2
“This technological advancement has expanded the scope of traditional diagnostic ultrasound, facilitating continuous monitoring but still needs more research to unlock a wide range of clinical applications [2].”
Compressed Plane-Wave Compounding for Efficient Imaging on Portable Ultrasound Devices
Trivedi, D., Huan, J., Madanayake, A., Bhunia, S., & Mandal, S. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798366 · Cited by 2
“3(a) shows a typical use case for the device [15], [16], namely image-guided vagus nerve modula-tionusing a dual-mode body-conformal ultrasound probe [17].”
Self-citationJavid, A., Zhao, C., & Kiani, M. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948689 · Cited by 2
“Recently, several US transducer arrays with different specifications have been reported in the literature for USN applications [10]-[13].”
BackgroundAn Acoustically Transparent Electrical Cap for Piezoelectric Ultrasound Transducers on Silicon
Wardhana, G. K., Costa, T. L., & Mastrangeli, M. (2024) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings2024097050 · Cited by 2
“Therapeutic neuromodulation is a promising biomedical application of focused ultrasound which, compared to imaging, introduces design emphasis on high transmit efficiency and small form factor [1].”
BackgroundOnline Scaphoid Tracking Using a Wearable and Flexible Ultrasound Array: A First Proof of Concept
Rostamikhanghahi, H., Ingram, M., Booth, B. G., & D’hooge, J. (2025) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2025.3566006 · Cited by 1
“Pashaei et al. integrated matrices of PZT elements onto a flexible printed circuit board (PCB) to create flexible, linear transducer arrays for image-guided neural modulation [7].”
Song, Z., Güler, Ü., & Chandrakasan, A. P. (2025) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas67066.2025.00026 · Cited by 1
“However, due to high computational and memory demands, existing wearable ultrasound devices [1], [2], [7], [8] rely on cloud-based computing for image segmentation, which raises privacy and security concerns and limits usage to areas with reliable Internet.”
Song, Z., Güler, Ü., & Chandrakasan, A. P. (2026) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2026.3676752 · Cited by 1
“Current wearable ultrasound devices consequently rely on cloud-based computing for segmentation [7], [8], [9], [10], [11], which raises critical privacy and security concerns for sensitive medical data and restricts deployment to areas with reliable Internet connectivity.”
Waataja, J. J., Ikramuddin, S., Gal, D., & Billington, C. J. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.1002713 · Cited by 1
Saleh, A. Y., Setiobudi, T., & Hashuro, M. S. S. (2023) · Bali Medical Journal · doi:10.15562/bmj.v12i3.4775 · Cited by 1
Modulating Neural Oscillations with Transcranial Focused Ultrasound
Sanguinetti, J. L. (2022) · Studies in Rhythm Engineering · doi:10.1007/978-981-16-5723-8_2 · Cited by 1
2020 Index IEEE Transactions on Biomedical Circuits and Systems Vol. 14
(2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3059009
Fernández, M. Á. G. (2023) · Revista de ecocardiografía práctica y otras técnicas de imagen cardíaca · doi:10.37615/retic.v6n1a1
Wearable Ultrasound Probe for Nerve Localization and Stimulation
Pashaei, V., Huan, J., Chen, H., Osman, M. S. E. A., Kothapalli, S., Majerus, S. J. A., & Mandal, S. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388793
Self-citationA Flexible Body-Conformable Ultrasound Transducer Array for Neuromodulation Applications
Zhang, J., Guo, L., Xu, H., & Peng, C. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10794121
“Considering the tendency for lower frequencies to be more effective in neuromodulation [10], the center frequency of FBUTA has been designed to be 0.7 MHz, enabling deep tissue penetration with minimal attenuation.”
InfluentialModulation neuronaler Oszillationen mit transkraniellem fokussiertem Ultraschall
Sanguinetti, J. L. (2024) · Springer eBooks · doi:10.1007/978-981-97-7610-8_2 · Cited by 1
Sundar, A., & Ganesan, A. (2025) · Communications in computer and information science · doi:10.1007/978-3-032-05144-8_14
Radhakrishnan, A., Aqamolaei, M., & Costa, T. L. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201673
“1a, optimized individually for imaging and therapy and operating at different frequencies and pulse durations [8], [9].”
Pyeon, J., Biswas, R., Kiani, M., & Tehranchi, F. (2025) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas53549.2025.11244513
“In general, flexible US arrays are preferable for wearable US applications, as they can conform to body shapes [6].”
Spiral-on-a-Curve: wireless photoacoustic neuromodulation patchPreprint
Zhang, S., Jiang, D., Lan, H., & Gao, F. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.04.708963
“Compared with traditional piezoelectric arrays ( 11–13, 15– 17 It is worth noting that large numerical apertures, while enabling tighter focusing, may introduce wavefront distortion in acoustically heterogeneous media.”
A Conformable CMOS Ultrasound System for Point-of-Care ImagingPreprint
Letchumanan, J. S., Gandhi, S., Yin, H., Blackman, S. G., Fabbri, J. D., Konofagou, E. E., Kessler, D. O., & Shepard, K. L. (2026) · medRxiv · doi:10.64898/2026.06.23.26356282
“Any systems that have incorporated electronics have done so at the scale of a single channel 17,18 or few channels 19 multiplexed to a larger number of transducers, significantly limiting the frame rate that can be achieved.”
Recent Advances in Wearable Ultrasound Patches for Healthcare Applications
Zou, F., & Xu, T. (2026) · Small · doi:10.1002/smll.76233
Metadata
- Authors
- Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S.
- Affiliations
- Case Western Reserve University (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-04
- Volume
- 14
- Issue
- 2
- Pages
- 305-318
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2995958784
- Semantic Scholar
- 9336151008efb8852b04da762c271f93fda22dbf
- Cited by
- 79
- References
- 54
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 16 · 2023: 25 · 2022: 10 · 2021: 10 · 2020: 2
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- low-intensity focused ultrasound, piezoelectric transducer array, nerve localization, strain sensors, beamforming, multiplexer, vagus nerve, tibial nerve
- MeSH terms
- Algorithms, Transcutaneous Electric Nerve Stimulation, Humans, Image Processing, Computer-Assisted, Neck, Signal Processing, Computer-Assisted, Ultrasonography, Ultrasonic Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.