Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
The DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.
Abstract
The paper presents the design and validation of body-conformal active ultrasound patches with integrated imaging and modulation modalities for image-guided neural therapy. A mechanically-flexible linear 64-element array of piezoelectric transducers with a resonance frequency of 5 MHz was designed for nerve localization. A second 8-element array using larger elements was integrated on the wearable probe for low intensity focused ultrasound neuromodulation at a resonance frequency of 1.3 MHz. Full-wave simulations were used to model the flexible arrays and estimate their generated pressure profiles. A focal depth of 10-20 mm was assumed for beamforming and focusing to support modulation of the vagus, tibial, and other nerves. A strain sensor integrated on the probe provides patient-specific feedback information on array curvature for real-time optimization of focusing and image processing. Each patch also includes high voltage (HV) multiplexers, transmit/receive switches, and pre-amplifiers that simplify connectivity and also improve the signal-to-noise ratio (SNR) of the received echo signals by ∼ 5 dB. Experimental results from a flexible prototype show a sensitivity of 80 kPa/V with ∼ 3 MHz bandwidth for the modulation and 20 kPa/V with ∼ 6 MHz bandwidth for the imaging array. An algorithm for accurate and automatic localization of targeted nerves based on using nearby blood vessels (e.g., the carotid artery) as image markers is also presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [524]
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155 · cited 4×
“, based on a partially-pretrained DCNN named AlexNet [48].”
MethodInfluentialCalculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493 · cited 1×
“imaging array was assessed in silico using the Field II ultrasound simulation package [45], [46].”
MethodBoone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Diagnostic ultrasound Imaging : Inside out
(2005) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2005-861725 · Cited by 761 · cited 1×
“arrays to obtain high-resolution images that allow differentiation of adjacent structures based on their echogenicity [39].”
BackgroundUltrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745 · cited 1×
“Ultrasound pressure waves can produce both thermal and mechanical effects while interacting with biological tissue [36], [37].”
BackgroundUnobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722 · cited 1×
“R ECENT advances in unobtrusive sensing and wearable technologies have enabled the pervasive long-term acquisition of physiological information for health informatics [1], [2].”
BackgroundHaghi, M., Thurow, K., & Stoll, R. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.4 · Cited by 711 · cited 1×
“R ECENT advances in unobtrusive sensing and wearable technologies have enabled the pervasive long-term acquisition of physiological information for health informatics [1], [2].”
BackgroundRemote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6689779 · Cited by 697 · cited 1×
“, several thousands frames per second) if required [47].”
BackgroundIntegration of optogenetics with complementary methodologies in systems neuroscience
Kim, C. K., Adhikari, A., & Deisseroth, K. (2017) · Nature reviews. Neuroscience · doi:10.1038/nrn.2017.15 · Cited by 690
Focused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundMechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564 · cited 1×
“Ultrasound pressure waves can produce both thermal and mechanical effects while interacting with biological tissue [36], [37].”
BackgroundEffective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundUltrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundLow-Intensity Focused Ultrasound Modulates Monkey Visuomotor Behavior
Deffieux, T., Younan, Y., Wattiez, N., Tanter, M., Pouget, P., & Aubry, J.-F. (2013) · Current Biology · doi:10.1016/j.cub.2013.10.029 · Cited by 392
Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces
Hu, H., Zhu, X., Wang, C., Zhang, L., Li, X., Lee, S., Huang, Z., Chen, R., Chen, Z., Wang, C., et al. (2018) · Science Advances · doi:10.1126/sciadv.aar3979 · Cited by 367 · cited 1×
“The improved angular coverage of the array results in higher image quality relative to rigid structures [40]–[42].”
BackgroundUltrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353 · cited 1×
“shapes and/or mean firing rates [14], [38].”
Application of infrared light for in vivo neural stimulation
Wells, J., Kao, C., Jansen, E. D., Konrad, P., & Mahadevan-Jansen, A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2121772 · Cited by 291
Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279 · cited 1×
“, retinal and cochlear implants) and neuroscience research [6]–[8].”
BackgroundUltrasonic modulation of neural circuit activity
Tyler, W. J., Lani, S. W., & Hwang, G. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.04.011 · Cited by 239
Neuromodulation : the biochemical control of neuronal excitability
Kaczmarek, L. K., & Levitan, I. B. (1987) · Oxford University Press eBooks · Cited by 233
Younan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundXu, R., Jiang, N., Mrachacz-Kersting, N., Lin, C., Asin Prieto, G., Moreno, J. C., Pons, J. L., Dremstrup, K., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2313867 · Cited by 185
Design considerations for piezoelectric polymer ultrasound transducers
Brown, L. F. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.883527 · Cited by 174 · cited 2×
“PZT and polyvinylidene fluoride (PVDF) have been widely used in earlier works [44].”
BackgroundMethodNeuromodulation: present and emerging methods
Luan, S., Williams, I., Nikolic, K., & Constandinou, T. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00027 · Cited by 162 · cited 1×
“The diversity and ubiquity of neuromodulation phenomena suggests its potential use for therapeutic purposes [35].”
BackgroundSit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155
In vitro effects of ultrasound with different energies on the conduction properties of neural tissue
Tsui, P.-H., Wang, S.-H., & Huang, C.-C. (2005) · Ultrasonics · doi:10.1016/j.ultras.2004.12.003 · Cited by 149 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundLee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140 · cited 1×
“, retinal and cochlear implants) and neuroscience research [6]–[8].”
BackgroundDesign considerations for piezoelectric polymer ultrasound transducers
Brown, L. F. (2002) · IEEE International Symposium on Applications of Ferroelectrics (ISAF) · doi:10.1109/isaf.2000.941553 · Cited by 122
Infrared neural stimulation: a new stimulation tool for central nervous system applications
Chernov, M. M., & Roe, A. W. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011011 · Cited by 102
Staskin, D. R., Peters, K. M., MacDiarmid, S., Shore, N. D., & de Groat, W. C. (2012) · Current Urology Reports · doi:10.1007/s11934-012-0274-9 · Cited by 92 · cited 4×
“At-home PTNS would greatly increase access to treatment but is limited by the need for a clinician to administer the necessary percutaneous electrical stimulation.”
BackgroundInfluentialFlexible ultrasonic transducers
Kobayashi, M., Jen, C., & Levesque, D. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1665105 · Cited by 90 · cited 1×
“The improved angular coverage of the array results in higher image quality relative to rigid structures [40]–[42].”
BackgroundJuan, E. J., González, R., Albors, G., Ward, M. P., & Irazoqui, P. (2014) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22080 · Cited by 78 · cited 2×
“vagus nerve (VN) modulation [25], [26], which is widely used to treat epilepsy, potentially chronic heart failure, and psychiatric”
BackgroundMethodBackground Removal and Vessel Filtering of Noncontrast Ultrasound Images of Microvasculature
Bayat, M., Fatemi, M., & Alizad, A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2858205 · Cited by 77 · cited 1×
“driving the long cable (typically 1–2 m) between the probe and receiver, thus improving the sensitivity for localizing small body organs such as blood vessels [31].”
BackgroundSelf-citationStudies on the circuit models of piezoelectric ceramics
Guan, M., & Liao, W. (2005) · IEEE International Conference on Information Acquisition · doi:10.1109/icia.2004.1373314 · Cited by 70 · cited 1×
“The transducer is modeled using an RLC equivalent circuit, known as the Guan model [50].”
MethodLee, J.-H., Cho, I.-J., Ko, K., Yoon, E.-S., Park, H.-H., & Kim, T. S. (2017) · Microsystem Technologies · doi:10.1007/s00542-016-2912-5 · Cited by 68 · cited 1×
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundElectrical stimulation with non-implanted electrodes for overactive bladder in adults
Stewart, F. J., Gameiro, L. F. O., Dib, R. E., Gameiro, M. O., Kapoor, A., & Amaro, J. L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010098.pub4 · Cited by 60 · cited 1×
“tially major application in humans is percutaneous tibial nerve stimulation (PTNS) [22], [23].”
BackgroundElectrical stimulation with non-implanted electrodes for overactive bladder in adults
Stewart, F. J., Gameiro, O. L., Dib, R. E., Gameiro, M. O., Kapoor, A., & Amaro, J. L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010098.pub3 · Cited by 32
Singh, R. S., Culjat, M. O., Vampola, S., Williams, K. J., Taylor, Z. D., Lee, H., Grundfest, W. S., & Brown, E. R. (2007) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2007.459 · Cited by 21
Ultrasound-induced heart rate decrease: role of the vagus nerve
Coiado, O. C., Buiochi, E. B., & O’Brien, W. D. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006755 · Cited by 14 · cited 3×
“vagus nerve (VN) modulation [25], [26], which is widely used to treat epilepsy, potentially chronic heart failure, and psychiatric”
BackgroundMethodPolyimide-Based Conformal Ultrasound Transducer Array for Needle Guidance
Culjat, M. O., Bennett, D. B., Lee, M. J., Brown, E. R., Lee, H., Grundfest, W. S., & Singh, R. S. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030270 · Cited by 13 · cited 2×
“Earlier works present the preliminary concept and functionality of flexible transducers and sensors for body-conformality and compensation of user variability in applications such as i) bladder volume detection, and ii) vascular and carotid artery monitoring [27]–[29].”
BackgroundA Programmable Sustaining Amplifier for Flexible Multimode MEMS-Referenced Oscillators
Islam, M. S., Singh, S., Lee, J., Xie, Y. J., Zorman, C. A., Feng, P. X. ‐., & Mandal, S. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2880675 · Cited by 12
Self-citationConformal Ultrasound Transducer Array for Image-Guided Neural Therapy
Pashaei, V., Roman, A., & Mandal, S. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584727 · Cited by 12 · cited 2×
“It builds upon our earlier work on VN imaging and modulation [30],”
BackgroundResultSelf-citationFlexible, structured MWCNT/PDMS sensor for chronic vascular access monitoring
Majerus, S. J. A., Dunning, J. L., Potkay, J. A., & Bogie, K. M. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808630 · Cited by 11
Self-citationA wearable carotid ultrasound assembly for early detection of cardiovascular diseases
Shomaji, S., Basak, A., Mandai, S., Karam, R., & Bhunia, S. (2016) · IEEE Healthcare Innovations and Point of Care Technologies Conference (HI-POCT) · doi:10.1109/hic.2016.7797686 · Cited by 10
An Open-Source Test-Bench for Autonomous Ultrasound Imaging
Roman, A., Dehghanzadeh, P., Pashaei, V., Basak, A., Bhunia, S., & Mandal, S. (2018) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2018.8623834 · Cited by 7 · cited 3×
“The received echo signals from individual transducer elements were recorded by a custom 8-channel ultrasound test bench [32].”
BackgroundMethodSelf-citationOveractive Bladder Syndrome and Urinary Incontinence
(2011) · Oxford University Press eBooks · doi:10.1093/med/9780199599394.001.0001 · Cited by 4 · cited 1×
“in 7–27% of men and 9–43% of women [24].”
An Open-Source Ultrasound Imaging System with Wearable Active Probes
Enwia, G., Pashaei, V., Bayat, M., Roman, A., & Mandal, S. (2019) · IEEE National Aerospace and Electronics Conference (NAECON) · doi:10.1109/naecon46414.2019.9058162 · Cited by 1 · cited 1×
“The custom transceiver board contains the analog front-end that interfaces with both the flexible probe and the back-end SoC architecture [49].”
Self-citation
Research works printed but not linked: 3
- aggarwal, 0, Automated positioning of ultrasonic probes, Proc Nat Aerosp Electron Conf, 1
- kaczmarek, 1987, et�al
- jensen, 0, Field: A program for simulating ultrasound systems, Proc 10th NordicBaltic Conf Biomed Imag, 4, 351
Cited by
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
A conformable phased-array ultrasound patch for bladder volume monitoring
Zhang, L., Marcus, C., Lin, D., Mejorado, D., Schoen, S. J., Pierce, T. T., Kumar, V., Fernandez, S. V., Hunt, D., Li, Q., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01068-x · Cited by 148
Metadata
- Authors
- Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S.
- Affiliations
- Case Western Reserve University (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-04
- Volume
- 14
- Issue
- 2
- Pages
- 305-318
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2995958784
- Semantic Scholar
- 9336151008efb8852b04da762c271f93fda22dbf
- Cited by
- 79
- References
- 54
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 16 · 2023: 25 · 2022: 10 · 2021: 10 · 2020: 2
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- low-intensity focused ultrasound, piezoelectric transducer array, nerve localization, strain sensors, beamforming, multiplexer, vagus nerve, tibial nerve
- MeSH terms
- Algorithms, Transcutaneous Electric Nerve Stimulation, Humans, Image Processing, Computer-Assisted, Neck, Signal Processing, Computer-Assisted, Ultrasonography, Ultrasonic Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.