A Multistage Process for Computing Virtual Dipolar Sources of EEG Discharges from Surface Information
The DOI matches its Crossref record.
Abstract
A mathematical model consisting of a homogeneous spherical conductive medium was used to simulate the human head. A current dipole situated in the interior of the sphere produces, on the surface, a theoretical distribution of potential similar to certain EEG activities recorded on the human scalp. We propose a multi-stage method for computing the six parameters of a such virtual dipolar source by using only measurements on the surface of the scalp. Epileptic discharges observed on a young patient were thus analyzed. The computed dipole depends on the placement of pairs of electrodes used for the record. We compare the results of four ``assemblies'' using different pairings of electrodes. The center of the dipole varies within a volume of 2 cm3but its direction is stable. We discuss the importance and the influence of the approximations introduced by the model and the method. Although these approximations cannot be neglected, they do not change the signification of our results. The question is now raised: Has the virtual source a physical interpretation? Only intracerebral investigations can bring about a clear answer. However, whatever the answer may be, it appears that the method presented here can be helpful in the analysis of EEG surface situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334
Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
A new interpretation of the generators of BAEP waves I–V: Results of a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90006-1 · Cited by 299
Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain
Kavanagk, R. N., Darcey, T. M., Lehmann, D., & Fender, D. H. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326339 · Cited by 276
Functional imaging and localization of electromagnetic brain activity
Scherg, M. (1992) · Brain Topography · doi:10.1007/bf01129037 · Cited by 253
THE FUNCTIONAL NEUROANATOMY OF EVENT RELATED POTENTIALS
GOFF, W. R., ALLISON, T., & VAUGHAN, H. G. (1978) · Event-Related Brain Potentials in Man · doi:10.1016/b978-0-12-155150-6.50007-9 · Cited by 173
The Upper and Lower Visual Field of Man: Electrophysiological and Functional Differences
Skrandies, W. (1987) · Progress in Sensory Physiology · doi:10.1007/978-3-642-71060-5_1 · Cited by 159
EEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Metadata
- Authors
- Schneider, M. R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1972-01
- Volume
- BME-19
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2095330691
- Cited by
- 101
- References
- 0
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.