Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

An Integrated Field-Effect Electrode for Biopotential Recording

Matsuo, Tadayuki, Wise, Kensall D.·1974·IEEE Transactions on Biomedical Engineering

Abstract

An integrated liquid-oxide-semiconductor FET structure is described. The structure is similar to a conventional n-channel depletion mode MOSFET except the gate metal is omitted. Immersing the device in a saline solution, the drain current is controlled by the potential between the source and the solution. Operated as an active recording electrode, the structure has several properties useful in neurological research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1974.324338

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 235

Metadata

Authors
Matsuo, T., & Wise, K. D.
Venue
IEEE Transactions on Biomedical Engineering
Published
1974-11
Volume
BME-21
Issue
6
Pages
485-487
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2075081745
Cited by
235
References
3
FWCI
0.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Integrated Field-Effect Electrode for Biopotential Recording. https://app.cochat.ai/papers/10.1109/tbme.1974.324338
The paper
Matsuo, T., & Wise, K. D. (1974). An Integrated Field-Effect Electrode for Biopotential Recording. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1974.324338

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.