An Evaluation of the Resistance to Electrolysis of Metals for Use in Biostimulation Microprobes
The DOI matches its Crossref record.
Abstract
Electrolysis measurements have been made on electrodes of platinum, stainless steel, tungsten, iridium, palladium, rhodium, rhenium, gold, tantalum, titanium, zirconium, and some conducting oxides of the tungsten bronze family. Electrodes were immersed in physiologic saline solution and subjected to biphasic rectangular current pulses of various current densities at 50 pps, 24 hours per day for periods up to nine months. Weight loss was recorded at intervals during this time. We conclude that iridium,rhodium, platinum and palladium are extremely resistant to electrolysis under these conditions and electrolysis under 5μ thick, made of such materials should have lifetimes on the order of decades. Gold is somewhat poorer but probably acceptable; all the other materials tested, including tungsten and stainless steel, are unacceptable as chronic microelectrode materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Metadata
- Authors
- White, R. L., & Gross, T. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1974-11
- Volume
- BME-21
- Issue
- 6
- Pages
- 487-490
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2027539092
- Cited by
- 56
- References
- 0
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Evaluation of the Resistance to Electrolysis of Metals for Use in Biostimulation Microprobes. https://app.cochat.ai/papers/10.1109/tbme.1974.324339
- The paper
- White, R. L., & Gross, T. J. (1974). An Evaluation of the Resistance to Electrolysis of Metals for Use in Biostimulation Microprobes. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1974.324339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.