Abstract

Electrolysis measurements have been made on electrodes of platinum, stainless steel, tungsten, iridium, palladium, rhodium, rhenium, gold, tantalum, titanium, zirconium, and some conducting oxides of the tungsten bronze family. Electrodes were immersed in physiologic saline solution and subjected to biphasic rectangular current pulses of various current densities at 50 pps, 24 hours per day for periods up to nine months. Weight loss was recorded at intervals during this time. We conclude that iridium,rhodium, platinum and palladium are extremely resistant to electrolysis under these conditions and electrolysis under 5μ thick, made of such materials should have lifetimes on the order of decades. Gold is somewhat poorer but probably acceptable; all the other materials tested, including tungsten and stainless steel, are unacceptable as chronic microelectrode materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1974.324339

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
White, R. L., & Gross, T. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1974-11
Volume
BME-21
Issue
6
Pages
487-490
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2027539092
Cited by
56
References
0
FWCI
0.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.