A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A multielectrode structure containing integrated junction-FET input stages is described. Photoengraved microelectrodes are utilized to obtain high dimensional precision, small size, and extremely low capacitive coupling between electrodes. The interelectrode capacitance is less than 0.01 pf. The integrated input devices (JFET's) reduce the impedance levels on the recording channels to less than 500 ohms, virtually eliminating crosstalk and stray noise pickup from the system. The n-channel JFET's operate as source-followers from a common 2.5 volt drain supply and have input impedances greater than 100 megohms at 1 kHz. A simple external preamplifier ensures stable operation and easy interfacing with conventional recording and display equipment. Special considerations in the design of low-noise completely integrated input stages for use with metal microelectrodes are discussed in detail. As a result of the low interelectrode coupling in this structure, simultaneous recording and stimulation from closely adjacent areas of brain should be possible with virtually no stimulus artifact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 1×
“The fabrication and performance of such photoengraved microelectrodes are described elsewhere [1], [2] .”
BackgroundSelf-citation
Cited by
Barthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 887
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Metadata
- Authors
- Wise, K. D., & Angell, J. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1975-05
- Volume
- BME-22
- Issue
- 3
- Pages
- 212-219
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2040996230
- Cited by
- 157
- References
- 1
- FWCI
- 0.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology. https://app.cochat.ai/papers/10.1109/tbme.1975.324562
- The paper
- Wise, K. D., & Angell, J. B. (1975). A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1975.324562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.