Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record.

An Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser Light

Watkins, Dennis, Holloway, G. Allen·1978·IEEE Transactions on Biomedical Engineering

Abstract

A system utilizing the Doppler shift of monochromatic laser light has been developed to measure blood flow in skin. Light from a low power (S mW) He-Ne laser is coupled into a quartz fiber and transmitted to the skin. This light is reflected from both the nonmoving tissues (reference beam) and moving red blood cells (Doppler shifted beam), received by a plastic fiber, and transmitted back to a photodiode where optical heterodyning occurs. The heterodyned output signal, which is proportional to the Doppler shift frequency, is amplified and both RMS and dc values obtained. The RMS value is weighted against the backscattered light intensity using the measured dc value as an index of total received power. This is used as the output flow velocity value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1978.326374

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Watkins, D., & Holloway, G. A.
Venue
IEEE Transactions on Biomedical Engineering
Published
1978-01
Volume
BME-25
Issue
1
Pages
28-33
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2007388493
Cited by
201
References
0
FWCI
5.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.