CoChat

Closed-Loop Control of Force During Electrical Stimulation of Muscle

Crago, Patrick E., Mortimer, J. Thomas, Peckham, P. Hunter · 1980 · IEEE Transactions on Biomedical Engineering
Cited by 135

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The control of contractions elicited by electrical stimulation of muscle could be improved if there was a linear repeatable input-output relationship. The input is the command to the controlled stimulator and the output is the evoked contraction. Systems employing closed-loop force feedback to provide regulation of contractions were investigated in these studies. Force was modulated by both recruitment and temporal summation during intramuscular stimulation. Closed-loop systems with combined proportional and integral control were found to be stable and linear and to have good compensation for variations in muscle properties. A low proportional loop gain (approximately unity) was found necessary to prevent oscillation when modulating recruitment. Ratios of integral to proportional gain of about 10 gave the fastest response without compromising stability. The response time of the closed-loop system was as fast as or faster than the open-loop system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1980.326738

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Crago, P. E., Mortimer, J. T., & Peckham, P. H.
Venue
IEEE Transactions on Biomedical Engineering
Published
1980-06
Volume
BME-27
Issue
6
Pages
306-312
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2125075171
Cited by
135
References
2
FWCI
5.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.