CoChat

A Practical 24 Channel Microelectrode for Neural Recording in Vivo

Kuperstein, Michael, Whittington, Douglas A. · 1981 · IEEE Transactions on Biomedical Engineering
Cited by 72

The DOI matches its Crossref record.

Abstract

We have developed a multichannel microelectrode that has 24 recording sites, spaced at 85 μm intervals along the edge of its tip. The sites are arranged in one of two ways: either as a 1 ×24 linear array along one edge or as a 2 ×12 array along both edges. In the first, the sites span 2 mm while in the second, the sites span 1 mm ×135 μm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1981.324702

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Kuperstein, M., & Whittington, D. A.
Venue
IEEE Transactions on Biomedical Engineering
Published
1981-03
Volume
BME-28
Issue
3
Pages
288-293
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W1982891222
Cited by
72
References
0
FWCI
1.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Practical 24 Channel Microelectrode for Neural Recording in Vivo. https://app.cochat.ai/papers/10.1109/tbme.1981.324702
The paper
Kuperstein, M., & Whittington, D. A. (1981). A Practical 24 Channel Microelectrode for Neural Recording in Vivo. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1981.324702

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.