The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
The weighted diagnostic distortion (WDD) measure for ECG signal compression
Abstract
In this paper, a new distortion measure for electrocardiogram (ECG) signal compression, called weighted diagnostic distortion (WDD) is introduced. The WDD measure is designed for comparing the distortion between original ECG signal and reconstructed ECG signal (after compression). The WDD is based on PQRST complex diagnostic features (such as P wave duration, QT interval, T shape, ST elevation) of the original ECG signal and the reconstructed one. Unlike other conventional distortion measures [e.g. percentage root mean square (rms) difference, or PRD], the WDD contains direct diagnostic information and thus is more meaningful and useful. Four compression algorithms were implemented (AZTEC, SAPA2, LTP, ASEC) in order to evaluate the WDD. A mean opinion score (MOS) test was applied to test the quality of the reconstructed signals and to compare the quality measure (MOSerror) with the proposed WDD measure and the popular PRD measure. The evaluators in the MOS test were three independent expert cardiologists, who studied the reconstructed ECG signals in a blind and a semiblind tests. The correlation between the proposed WDD measure and the MOS test measure (MOSerror) was found superior to the correlation between the popular PRD measure and the MOSerror.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Electronics: A First Course · doi:10.4324/9780080477527-64 · Cited by 24,923
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Vector Quantization and Signal Compression
Gersho, A., & Gray, R. M. (1992) · Springer eBooks · doi:10.1007/978-1-4615-3626-0 · Cited by 7,003
Hahn, G. J., Draper, N., & Smith, H. (1982) · Technometrics · doi:10.2307/1267833 · Cited by 5,773
Applied Regression Analysis (2nd ed).
de Carvalho, J. F., Draper, N. R., & Smith, H. (1981) · Journal of the American Statistical Association · doi:10.2307/2287608 · Cited by 3,044
Introduction to Data Compression
(2018) · Elsevier eBooks · doi:10.1016/c2015-0-06248-7 · Cited by 2,129
Lee, E. A., & Messerschmitt, D. G. (1994) · Springer eBooks · doi:10.1007/978-1-4615-3136-4 · Cited by 1,683
No, P. (1986) · Cited by 1,532
Barratt, K. H. (1985) · Electronics and Power · doi:10.1049/ep.1985.0201 · Cited by 1,523
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
Kleijn, W. B., & Paliwal, K. K. (1995) · Elsevier eBooks · Cited by 847
ECG data compression techniques-a unified approach
Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52340 · Cited by 681
Wavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415
The MIT-BIH Arrhythmia Database on CD-ROM and software for use with it
Moody, G. B., & Mark, R. G. (2002) · [1990] Proceedings Computers in Cardiology · doi:10.1109/cic.1990.144205 · Cited by 404
Biomedical Digital Signal Processing
Tompkins, W. J. (1993) · Cited by 402
AZTEC, a Preprocessing Program for Real-Time ECG Rhythm Analysis
Cox, J. R., Nolle, F. M., Fozzard, H. A., & Oliver, G. C. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502549 · Cited by 367
A New Data-Reduction Algorithm for Real-Time ECG Analysis
Abenstein, J. P., & Tompkins, W. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324962 · Cited by 269
Biomedical Signal Processing: Innovation and Applications
(2021) · Springer eBooks · doi:10.1007/978-3-030-67494-6 · Cited by 261
Software QRS detection in ambulatory monitoring — a review
Pahlm, O., & Sörnmo, L. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442095 · Cited by 253
New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications
Laguna, P., Thakor, N. V., Caminal, P., Jané, R., Yoon, H.-R., Bayés de Luna, A., Marti, V., & Guindo, J. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441680 · Cited by 228
Scan-Along Polygonal Approximation for Data Compression of Electrocardiograms
Ishijima, M., Shin, S.-B., Hostetter, G. H., & Sklansky, J. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325186 · Cited by 137
ECG coding by wavelet-based linear prediction
Ramakrishnan, A. G., & Saha, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649997 · Cited by 130
Modelling ECG signals with hidden Markov models
Koski, A. (1996) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(96)00352-1 · Cited by 109
Detection of the P and T waves in an ECG
Gritzali, F., FRANGAKIS, G. P., & Papakonstantinou, G. (1989) · Computers and Biomedical Research · doi:10.1016/0010-4809(89)90017-7 · Cited by 108
Cohen, A. D. (2019) · CRC Press eBooks · doi:10.1201/9780429290800 · Cited by 85
Self-citationA diagnostic meaningful distortion measure for ECG compression
Zigel, Y., Cohen, A. D., & Katz, A. (2002) · IEEE Convention of Electrical and Electronics Engineers in Israel · doi:10.1109/eeis.1996.566907 · Cited by 12
Self-citationANN compression of morphologically similar ECG complexes
Hamilton, D. J., Thomson, D., & Sandham, W. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523019 · Cited by 12
SAIES – A New ECG Data Compression Algorithm
Jalaleddine, S. M. S., & Hutchens, C. G. (1990) · Journal of Clinical Engineering · doi:10.1097/00004669-199001000-00010 · Cited by 9
Cited by
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
Sayadi, O., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921150 · Cited by 254
CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Huang, H., Hu, S., & Sun, Y. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3341559 · Cited by 10
Metadata
- Authors
- Zigei, Y., Cohen, A., & Katz, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-11
- Volume
- 47
- Issue
- 11
- Pages
- 1422-1430
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2154483232
- Cited by
- 405
- References
- 28
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.