Extracellular Recordings From Patterned Neuronal Networks Using Planar Microelectrode Arrays
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Neuronal cell networks have been reconstructed on planar microelectrode arrays (MEAs) from dissociated hippocampal pyramidal neurons. Microcontact printing (microCP) and a photoresist-liftoff method were used to selectively localize poly-L-lysine (PLL) on the surface of MEAs. Haptotaxis led to the organization of the neurons into networks localized adjacent to microelectrodes. Various grids of PLL with 2-25-microm-wide lines spaced by 50-200 microm with 15-25-microm nodes at intersection points were used to guide cell body attachment and neurite outgrowth. Bursting activity with spike amplitude attenuation was observed, and multichannel recordings detected instances of coincident firing activity. Finally, we present here an extracellular recording from a approximately 2 microm bundle of guided neurites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jimbo, Y., Robinson, H. P. C., & Kawana, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238465 · Cited by 192 · cited 1×
“organization of cell networks on recording devices [3], [8],”
Background
Cited by
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“…Frey et al. (2010), whereas passive MEA can have a significantly larger parasitic capacitance, depending on the thickness of the insulation and the track width [e.g., James et al. measured values of 60–100 pF (James et al., 2004) and Nisch et al. estimated it to be below 15 pF (Nisch et al., 1994)].”
Future lab-on-a-chip technologies for interrogating individual molecules
Craighead, H. (2006) · Nature · doi:10.1038/nature05061 · Cited by 672
Self-citationA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Nanowire-Based Nanoelectronic Devices in the Life Sciences
Patolsky, F., Timko, B. P., Zheng, G., & Lieber, C. M. (2007) · MRS Bulletin · doi:10.1557/mrs2007.47 · Cited by 342
A biofunctionalization scheme for neural interfaces using polydopamine polymer
Kang, K., Choi, I. S., & Nam, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.028 · Cited by 158
32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45
Metadata
- Authors
- James, C. D., Spence, A. J. H., Dowell-Mesfin, N. M., Hussain, R. J., Smith, K. L., Craighead, H. G., Isaacson, M. S., Shain, W., & Turner, J. N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-09
- Volume
- 51
- Issue
- 9
- Pages
- 1640-1648
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2160084586
- Cited by
- 124
- References
- 1
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.