A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Electrical extracellular stimulation of peripheral nerve activates the large-diameter motor fibers before the small ones, a recruitment order opposite the physiological recruitment of myelinated motor fibers during voluntary muscle contraction. Current methods to solve this problem require a long-duration stimulus pulse which could lead to electrode corrosion and nerve damage. The hypothesis that the excitability of specific diameter fibers can be suppressed by reshaping the profile of extracellular potential along the axon using multiple electrodes is tested using computer simulations in two different volume conductors. Simulations in a homogenous medium with a nine-contact electrode array show that the current excitation threshold (Ith) of large diameter axons (13-17 microm) (0.6-3.0 mA) is higher than that of small-diameter axons (2-7 microm) (0.4-0.7 mA) with 200-microm axon-electrode distance and 10-micros stimulus pulse. The electrode array is also tested in a three-dimensional finite-element model of the sacral root model of dog (ventral root of S3). A single cathode activates large-diameter axons before activating small axons. However, a nine-electrode array activates 50% of small axons while recruiting only 10% of large ones and activates 90% of small axons while recruiting only 50% of large ones. The simulations suggest that the near-physiological recruitment order can be achieved with an electrode array. The diameter selectivity of the electrode array can be controlled by the electrode separation and the method is independent of pulse width.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
CONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 1×
“, intramuscular [1], epimysial [2], intraneural [3], and epineural electrodes [4].”
BackgroundRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
A method to effect physiological recruitment order in electrically activated muscle
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76384 · Cited by 125 · cited 4×
“All of these techniques, however, require a relatively long stimulus pulse ( 500 us) to hyperpolarize and block the action potential propagation [7]–[12] or to inactivate the sodium channels [13]–[15].”
BackgroundMethodInfluentialMcCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446202 · Cited by 97 · cited 1×
“5) and therefore could be useful to minimize the nerve and electrode damage by using the narrow pulse width [16], [27].”
BackgroundBowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66 · cited 1×
“, intramuscular [1], epimysial [2], intraneural [3], and epineural electrodes [4].”
BackgroundRecruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · cited 1×
“A highly resistive boundary layer (5 mm) is added to reduce the effect of finite dimensions of the model by simulating an increased distance to the reference electrode [23].”
BackgroundMultielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41
Cited by
Aravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Current approaches to model extracellular electrical neural microstimulation
Joucla, S., Glière, A., & Yvert, B. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00013 · Cited by 78
“…1976; Rattay, 1986; Altman and Plonsey, 1990; Rubinstein, 1991) and estimate the activation thresholds of particular electrode configurations (Warman et al., 1992; Holsheimer and Wesselink, 1997; Lertmanorat and Durand, 2004; Rattay and Resatz, 2007; Joucla and Yvert, 2009a; Joucla et al., 2012b).”
BackgroundMaterial considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47
Stieglitz, T. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.2.149 · Cited by 16
Metadata
- Authors
- Lertmanorat, Z., & Durand, D. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-07
- Volume
- 51
- Issue
- 7
- Pages
- 1242-1250
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2118130368
- Cited by
- 30
- References
- 10
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study. https://app.cochat.ai/papers/10.1109/tbme.2004.827347
- The paper
- Lertmanorat, Z., & Durand, D. M. (2004). A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.827347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.