CoChat

A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study

Lertmanorat, Z., Durand, D.M. · 2004 · IEEE Transactions on Biomedical Engineering
Cited by 30

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Electrical extracellular stimulation of peripheral nerve activates the large-diameter motor fibers before the small ones, a recruitment order opposite the physiological recruitment of myelinated motor fibers during voluntary muscle contraction. Current methods to solve this problem require a long-duration stimulus pulse which could lead to electrode corrosion and nerve damage. The hypothesis that the excitability of specific diameter fibers can be suppressed by reshaping the profile of extracellular potential along the axon using multiple electrodes is tested using computer simulations in two different volume conductors. Simulations in a homogenous medium with a nine-contact electrode array show that the current excitation threshold (Ith) of large diameter axons (13-17 microm) (0.6-3.0 mA) is higher than that of small-diameter axons (2-7 microm) (0.4-0.7 mA) with 200-microm axon-electrode distance and 10-micros stimulus pulse. The electrode array is also tested in a three-dimensional finite-element model of the sacral root model of dog (ventral root of S3). A single cathode activates large-diameter axons before activating small axons. However, a nine-electrode array activates 50% of small axons while recruiting only 10% of large ones and activates 90% of small axons while recruiting only 50% of large ones. The simulations suggest that the near-physiological recruitment order can be achieved with an electrode array. The diameter selectivity of the electrode array can be controlled by the electrode separation and the method is independent of pulse width.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2004.827347

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 30

Metadata

Authors
Lertmanorat, Z., & Durand, D. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
2004-07
Volume
51
Issue
7
Pages
1242-1250
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2118130368
Cited by
30
References
10
FWCI
0.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study. https://app.cochat.ai/papers/10.1109/tbme.2004.827347
The paper
Lertmanorat, Z., & Durand, D. M. (2004). A Novel Electrode Array for Diameter-Dependent Control of Axonal Excitability: A Simulation Study. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.827347

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.