Impedance Characterization of Microarray Recording Electrodes in Vitro
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The mechanisms underlying performance degradation of chronically implanted silicon microelectrode arrays in the central nervous system (CNS) remain unclear. Humoral and cellular components of the brain foreign body response were evaluated to determine whether their presence on the electrode surface results in increased electrical impedance. Iridium oxide microelectrode recording arrays were electrically characterized in saline, culture media with 10% fetal bovine serum, and coated with various CNS cell types isolated from rat brain. Electrochemical impedance spectroscopy and cyclic voltammetry were performed using a three-electrode system. Potential cycling caused an immediate decrease in electrical impedance, which increased with time toward precycling values, with the effect of cycling remaining significant for several days. The addition of serum caused a significant increase in impedance of up to 28% relative to the saline control. Microelectrodes coated with various cell types known to participate in the foreign body response caused a 20%-80% increase in impedance immediately after contact that remained constant or gradually increased for several weeks. Our findings suggest that the attachment of molecular and cellular species following microelectrode implantation into brain tissue likely contribute to increases in impedance, but do not appear sufficient to hinder recording performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“Rousche and Normann [ 24 ] and Branner et al. [25] reported decreases in impedance after implantation of the Utah Electrode Array, although later investigation indicated that these decreases may have been due to breakdown of the electrode insulation (personal communication from R.A.Normann).”
BackgroundLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 1×
“Rousche and Normann [24] and Branner et al. [ 25 ] reported decreases in impedance after implantation of the Utah Electrode Array, although later investigation indicated that these decreases may have been due to breakdown of the electrode insulation (personal communication from R.A.Normann).”
BackgroundChronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · cited 1×
“Lefurge et al. [ 9 ] reported on impedance of platinum black electrodes in cat radial nerve.”
BackgroundMcCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634645 · Cited by 130 · cited 1×
“... diffusional barrier is formed, with changes occurring either at the electrode interface or the tissue surrounding the electrode following fibrous encapsulation [4], [6], [8]–[10]; movement of the electrode after implantation away from the recorded neurons [1], [11], [12]; breakage of the electrode [1], [13]; …”
Background
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Metadata
- Authors
- Merrill, D. R., & Tresco, P. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-11
- Volume
- 52
- Issue
- 11
- Pages
- 1960-1965
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2054449364
- Cited by
- 72
- References
- 4
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance Characterization of Microarray Recording Electrodes in Vitro. https://app.cochat.ai/papers/10.1109/tbme.2005.856245
- The paper
- Merrill, D. R., & Tresco, P. A. (2005). Impedance Characterization of Microarray Recording Electrodes in Vitro. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.856245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.